{"title":"All Transfers","description":"","products":[{"product_id":"s-line-transfer-for-open-tray-impression","title":"S-Line Transfer (for open tray impression)","description":"\u003cp data-start=\"71\" data-end=\"468\"\u003eThe \u003cstrong data-start=\"75\" data-end=\"114\"\u003eAlfa Gate S-Line Open Tray Transfer\u003c\/strong\u003e is a precision impression coping designed for accurate implant position capture using the open tray (pick-up) technique. Engineered specifically for the \u003cstrong data-start=\"268\" data-end=\"336\"\u003e3.0 mm S-Line internal hex platform (2.0 mm straight connection)\u003c\/strong\u003e, it ensures stable fixation during impression procedures and precise transfer of implant angulation and depth to the working model.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003ciframe title=\"Implant impression taking- open tray | Alfa Gate\" src=\"https:\/\/www.youtube.com\/embed\/ZjrKAG0hzWU\" height=\"720\" width=\"1280\"\u003e\u003c\/iframe\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2 data-start=\"475\" data-end=\"506\"\u003e\u003cstrong data-start=\"478\" data-end=\"506\"\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-start=\"507\" data-end=\"877\"\u003e\n\u003cli data-start=\"507\" data-end=\"556\"\u003e\n\u003cp data-start=\"509\" data-end=\"556\"\u003e\u003cstrong data-start=\"509\" data-end=\"526\"\u003eProduct Name:\u003c\/strong\u003e S-Line Transfer – Open Tray\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"557\" data-end=\"581\"\u003e\n\u003cp data-start=\"559\" data-end=\"581\"\u003e\u003cstrong data-start=\"559\" data-end=\"569\"\u003eSize:\u003c\/strong\u003e 14mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"582\" data-end=\"627\"\u003e\n\u003cp data-start=\"584\" data-end=\"627\"\u003e\u003cstrong data-start=\"584\" data-end=\"611\"\u003ePlatform Compatibility:\u003c\/strong\u003e S-Line 3.0 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"628\" data-end=\"685\"\u003e\n\u003cp data-start=\"630\" data-end=\"685\"\u003e\u003cstrong data-start=\"630\" data-end=\"650\"\u003eConnection Type:\u003c\/strong\u003e Internal Hex – 2.0 mm (Straight)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"686\" data-end=\"733\"\u003e\n\u003cp data-start=\"688\" data-end=\"733\"\u003e\u003cstrong data-start=\"688\" data-end=\"701\"\u003eMaterial:\u003c\/strong\u003e Medical-grade Stainless Steel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"734\" data-end=\"783\"\u003e\n\u003cp data-start=\"736\" data-end=\"783\"\u003e\u003cstrong data-start=\"736\" data-end=\"750\"\u003eTechnique:\u003c\/strong\u003e Open tray (pick-up) impression\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"784\" data-end=\"841\"\u003e\n\u003cp data-start=\"786\" data-end=\"841\"\u003e\u003cstrong data-start=\"786\" data-end=\"809\"\u003eRecommended Torque:\u003c\/strong\u003e 5–10 Ncm (light finger tight)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"842\" data-end=\"877\"\u003e\n\u003cp data-start=\"844\" data-end=\"877\"\u003e\u003cstrong data-start=\"844\" data-end=\"855\"\u003eDriver:\u003c\/strong\u003e 1.25 mm hand driver\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"879\" data-end=\"882\"\u003e\n\u003ch2 data-start=\"884\" data-end=\"903\"\u003e\u003cstrong data-start=\"887\" data-end=\"903\"\u003eKey Features\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-start=\"904\" data-end=\"1359\"\u003e\n\u003cli data-start=\"904\" data-end=\"1018\"\u003e\n\u003cp data-start=\"906\" data-end=\"1018\"\u003e\u003cstrong data-start=\"906\" data-end=\"926\"\u003ePick-Up Accuracy\u003c\/strong\u003e — Designed for direct impression removal with coping embedded in the impression material.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1019\" data-end=\"1101\"\u003e\n\u003cp data-start=\"1021\" data-end=\"1101\"\u003e\u003cstrong data-start=\"1021\" data-end=\"1047\"\u003eSecure Screw Retention\u003c\/strong\u003e — Ensures stable seating during impression capture.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1102\" data-end=\"1193\"\u003e\n\u003cp data-start=\"1104\" data-end=\"1193\"\u003e\u003cstrong data-start=\"1104\" data-end=\"1121\"\u003eHigh Rigidity\u003c\/strong\u003e — Stainless steel body prevents distortion under impression pressure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1194\" data-end=\"1277\"\u003e\n\u003cp data-start=\"1196\" data-end=\"1277\"\u003e\u003cstrong data-start=\"1196\" data-end=\"1229\"\u003ePrecise Interface Replication\u003c\/strong\u003e — Maintains exact S-Line 2.0 mm hex geometry.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1278\" data-end=\"1359\"\u003e\n\u003cp data-start=\"1280\" data-end=\"1359\"\u003e\u003cstrong data-start=\"1280\" data-end=\"1310\"\u003eControlled Torque Protocol\u003c\/strong\u003e — Low torque minimizes risk of component damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1361\" data-end=\"1364\"\u003e\n\u003ch2 data-start=\"1366\" data-end=\"1392\"\u003e\u003cstrong data-start=\"1369\" data-end=\"1392\"\u003eClinical Advantages\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-start=\"1393\" data-end=\"1585\"\u003e\n\u003cli data-start=\"1393\" data-end=\"1441\"\u003e\n\u003cp data-start=\"1395\" data-end=\"1441\"\u003eImproved accuracy for multiple implant cases\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1442\" data-end=\"1503\"\u003e\n\u003cp data-start=\"1444\" data-end=\"1503\"\u003eIdeal for full-arch or parallelism-sensitive restorations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1504\" data-end=\"1540\"\u003e\n\u003cp data-start=\"1506\" data-end=\"1540\"\u003eReduces positional discrepancies\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1541\" data-end=\"1585\"\u003e\n\u003cp data-start=\"1543\" data-end=\"1585\"\u003eEnhances passive fit of final prosthesis\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1587\" data-end=\"1590\"\u003e\n\u003ch2 data-start=\"1592\" data-end=\"1610\"\u003e\u003cstrong data-start=\"1595\" data-end=\"1610\"\u003eIndications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-start=\"1611\" data-end=\"1738\"\u003e\n\u003cli data-start=\"1611\" data-end=\"1638\"\u003e\n\u003cp data-start=\"1613\" data-end=\"1638\"\u003eMulti-unit restorations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1639\" data-end=\"1658\"\u003e\n\u003cp data-start=\"1641\" data-end=\"1658\"\u003eFull-arch cases\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1659\" data-end=\"1685\"\u003e\n\u003cp data-start=\"1661\" data-end=\"1685\"\u003eDeep implant placement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1686\" data-end=\"1738\"\u003e\n\u003cp data-start=\"1688\" data-end=\"1738\"\u003eSituations requiring maximum positional accuracy\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1740\" data-end=\"1743\"\u003e\n\u003ch2 data-start=\"1745\" data-end=\"1755\"\u003e\u003cstrong data-start=\"1748\" data-end=\"1755\"\u003eFAQ\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"1757\" data-end=\"1899\"\u003e\u003cstrong data-start=\"1757\" data-end=\"1812\"\u003eWhen should I use open tray instead of closed tray?\u003c\/strong\u003e\u003cbr data-start=\"1812\" data-end=\"1815\"\u003eOpen tray is recommended for multiple implants or when higher precision is required.\u003c\/p\u003e\n\u003cp data-start=\"1901\" data-end=\"2011\"\u003e\u003cstrong data-start=\"1901\" data-end=\"1946\"\u003eIs this compatible with NP or RP systems?\u003c\/strong\u003e\u003cbr data-start=\"1946\" data-end=\"1949\"\u003eNo. It is designed exclusively for \u003cstrong data-start=\"1984\" data-end=\"2010\"\u003eS-Line 3.0 mm implants\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"2013\" data-end=\"2123\"\u003e\u003cstrong data-start=\"2013\" data-end=\"2047\"\u003eWhat torque should be applied?\u003c\/strong\u003e\u003cbr data-start=\"2047\" data-end=\"2050\"\u003eApply \u003cstrong data-start=\"2056\" data-end=\"2094\"\u003e5–10 Ncm only (light finger tight)\u003c\/strong\u003e using a 1.25 mm hand driver.\u003c\/p\u003e\n\u003cp data-start=\"2125\" data-end=\"2219\"\u003e\u003cstrong data-start=\"2125\" data-end=\"2144\"\u003eIs it reusable?\u003c\/strong\u003e\u003cbr data-start=\"2144\" data-end=\"2147\"\u003eYes, if properly cleaned and sterilized according to standard protocols.\u003c\/p\u003e","brand":"Alfa Gate","offers":[{"title":"14mm \/ S-LINE PLATFORM \/ TRANSFERS","offer_id":43719165804796,"sku":"AGM-301-SL","price":18.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0657\/2788\/9660\/products\/AGM-301-SL.png?v=1662883165"},{"product_id":"s-line-transfer-with-click-connection","title":"S-Line Transfer (With Click Connection)","description":"\u003cp\u003eThe \u003cstrong data-end=\"125\" data-start=\"74\"\u003eAlfa Gate S-Line Transfer with Click Connection\u003c\/strong\u003e is a precision impression component engineered for accurate implant position transfer in S-Line 3.0 mm systems. Designed with a secure click-lock mechanism, it ensures stable seating during impression procedures, minimizing movement and improving impression accuracy for reliable prosthetic fabrication.\u003c\/p\u003e\n\u003cp\u003e\u003ciframe title=\"Implant impression taking- closed tray | Alfa Gate\" src=\"https:\/\/www.youtube.com\/embed\/61UIDl5kQmM\" height=\"720\" width=\"1280\"\u003e\u003c\/iframe\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2 data-end=\"467\" data-start=\"436\"\u003e\u003cstrong data-end=\"467\" data-start=\"439\"\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-end=\"829\" data-start=\"468\"\u003e\n\u003cli data-end=\"527\" data-start=\"468\"\u003e\n\u003cp data-end=\"527\" data-start=\"470\"\u003e\u003cstrong data-end=\"487\" data-start=\"470\"\u003eProduct Name:\u003c\/strong\u003e S-Line Transfer With Click Connection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"527\" data-start=\"468\"\u003e\n\u003cstrong\u003eSize:\u003c\/strong\u003e 9mm\u003c\/li\u003e\n\u003cli data-end=\"598\" data-start=\"553\"\u003e\n\u003cp data-end=\"598\" data-start=\"555\"\u003e\u003cstrong data-end=\"582\" data-start=\"555\"\u003ePlatform Compatibility:\u003c\/strong\u003e S-Line 3.0 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"665\" data-start=\"599\"\u003e\n\u003cp data-end=\"665\" data-start=\"601\"\u003e\u003cstrong data-end=\"621\" data-start=\"601\"\u003eConnection Type:\u003c\/strong\u003e Internal hex – 2.0 mm (straight geometry)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"713\" data-start=\"666\"\u003e\n\u003cp data-end=\"713\" data-start=\"668\"\u003e\u003cstrong data-end=\"681\" data-start=\"668\"\u003eMaterial:\u003c\/strong\u003e Medical-grade Stainless Steel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"772\" data-start=\"714\"\u003e\n\u003cp data-end=\"772\" data-start=\"716\"\u003e\u003cstrong data-end=\"724\" data-start=\"716\"\u003eUse:\u003c\/strong\u003e Impression taking \/ implant position transfer\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"829\" data-start=\"773\"\u003e\n\u003cp data-end=\"829\" data-start=\"775\"\u003e\u003cstrong data-end=\"799\" data-start=\"775\"\u003eRetention Mechanism:\u003c\/strong\u003e Mechanical click engagement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"834\" data-start=\"831\"\u003e\n\u003ch2 data-end=\"866\" data-start=\"836\"\u003e\u003cstrong data-end=\"866\" data-start=\"839\"\u003eKey Features \u0026amp; Benefits\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-end=\"1309\" data-start=\"867\"\u003e\n\u003cli data-end=\"962\" data-start=\"867\"\u003e\n\u003cp data-end=\"962\" data-start=\"869\"\u003e\u003cstrong data-end=\"893\" data-start=\"869\"\u003eClick-Lock Stability\u003c\/strong\u003e — Audible and tactile seating confirmation for secure positioning.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1056\" data-start=\"963\"\u003e\n\u003cp data-end=\"1056\" data-start=\"965\"\u003e\u003cstrong data-end=\"986\" data-start=\"965\"\u003eAccurate Transfer\u003c\/strong\u003e — Maintains exact implant orientation during impression procedures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1152\" data-start=\"1057\"\u003e\n\u003cp data-end=\"1152\" data-start=\"1059\"\u003e\u003cstrong data-end=\"1081\" data-start=\"1059\"\u003eRigid Construction\u003c\/strong\u003e — Stainless steel body resists distortion under impression pressure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1226\" data-start=\"1153\"\u003e\n\u003cp data-end=\"1226\" data-start=\"1155\"\u003e\u003cstrong data-end=\"1177\" data-start=\"1155\"\u003eEfficient Workflow\u003c\/strong\u003e — Simplifies impression placement and removal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1309\" data-start=\"1227\"\u003e\n\u003cp data-end=\"1309\" data-start=\"1229\"\u003e\u003cstrong data-end=\"1251\" data-start=\"1229\"\u003ePlatform Precision\u003c\/strong\u003e — Specifically calibrated for S-Line connection geometry.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"1314\" data-start=\"1311\"\u003e\n\u003ch2 data-end=\"1344\" data-start=\"1316\"\u003e\u003cstrong data-end=\"1344\" data-start=\"1319\"\u003eClinical Applications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-end=\"1490\" data-start=\"1345\"\u003e\n\u003cli data-end=\"1382\" data-start=\"1345\"\u003e\n\u003cp data-end=\"1382\" data-start=\"1347\"\u003eClosed tray impression procedures\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1411\" data-start=\"1383\"\u003e\n\u003cp data-end=\"1411\" data-start=\"1385\"\u003eSingle-unit restorations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1446\" data-start=\"1412\"\u003e\n\u003cp data-end=\"1446\" data-start=\"1414\"\u003eMulti-unit prosthetic planning\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1490\" data-start=\"1447\"\u003e\n\u003cp data-end=\"1490\" data-start=\"1449\"\u003eDigital or conventional workflow models\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"1495\" data-start=\"1492\"\u003e\n\u003ch2 data-end=\"1507\" data-start=\"1497\"\u003e\u003cstrong data-end=\"1507\" data-start=\"1500\"\u003eFAQ\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-end=\"1620\" data-start=\"1509\"\u003e\u003cstrong data-end=\"1555\" data-start=\"1509\"\u003eIs this compatible with NP or RP implants?\u003c\/strong\u003e\u003cbr data-end=\"1558\" data-start=\"1555\"\u003eNo. It is designed exclusively for \u003cstrong data-end=\"1619\" data-start=\"1593\"\u003eS-Line 3.0 mm implants\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-end=\"1769\" data-start=\"1622\"\u003e\u003cstrong data-end=\"1670\" data-start=\"1622\"\u003eWhat is the purpose of the click connection?\u003c\/strong\u003e\u003cbr data-end=\"1673\" data-start=\"1670\"\u003eThe click mechanism confirms full seating and prevents micro-movement during impression capture.\u003c\/p\u003e\n\u003cp data-end=\"1865\" data-start=\"1771\"\u003e\u003cstrong data-end=\"1790\" data-start=\"1771\"\u003eIs it reusable?\u003c\/strong\u003e\u003cbr data-end=\"1793\" data-start=\"1790\"\u003eYes, if sterilized and handled according to standard clinical protocols.\u003c\/p\u003e","brand":"Alfa Gate","offers":[{"title":"9mm \/ S-LINE PLATFORM \/ TRANSFERS","offer_id":43719197229308,"sku":"AGM-302-SL","price":30.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0657\/2788\/9660\/products\/AGM-302-SL.png?v=1662883607"},{"product_id":"implant-transfer-np","title":"Implant transfers NP","description":"\u003cp data-start=\"150\" data-end=\"601\"\u003eThe \u003cstrong data-start=\"154\" data-end=\"187\"\u003eAlfa Gate Implant Transfer NP\u003c\/strong\u003e is a precision-engineered impression component designed for accurate implant position transfer in laboratory and clinical workflows. Built for \u003cstrong data-start=\"331\" data-end=\"366\"\u003eNarrow Conical Platform systems\u003c\/strong\u003e, it ensures stable seating, precise indexing, and reliable impression accuracy for prosthetic fabrication. Manufactured from medical-grade stainless steel, it delivers durability and dimensional stability throughout repeated handling.\u003c\/p\u003e\n\u003chr data-start=\"603\" data-end=\"606\"\u003e\n\u003ch2 data-start=\"608\" data-end=\"639\"\u003e\u003cstrong data-start=\"611\" data-end=\"639\"\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-start=\"640\" data-end=\"1092\"\u003e\n\u003cli data-start=\"640\" data-end=\"681\"\u003e\n\u003cp data-start=\"642\" data-end=\"681\"\u003e\u003cstrong data-start=\"642\" data-end=\"659\"\u003eProduct Name:\u003c\/strong\u003e Implant Transfer NP\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"707\" data-end=\"767\"\u003e\n\u003cp data-start=\"709\" data-end=\"767\"\u003e\u003cstrong data-start=\"709\" data-end=\"736\"\u003ePlatform Compatibility:\u003c\/strong\u003e Narrow Conical Platform (NP)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"768\" data-end=\"816\"\u003e\n\u003cp data-start=\"770\" data-end=\"816\"\u003e\u003cstrong data-start=\"770\" data-end=\"790\"\u003eConnection Type:\u003c\/strong\u003e Conical – 22° interface\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"817\" data-end=\"850\"\u003e\n\u003cp data-start=\"819\" data-end=\"850\"\u003e\u003cstrong data-start=\"819\" data-end=\"832\"\u003eMaterial:\u003c\/strong\u003e Stainless Steel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"851\" data-end=\"925\"\u003e\n\u003cp data-start=\"853\" data-end=\"925\"\u003e\u003cstrong data-start=\"853\" data-end=\"879\"\u003eTorque Recommendation:\u003c\/strong\u003e Manual only — light finger tight (5–10 Ncm)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"926\" data-end=\"970\"\u003e\n\u003cp data-start=\"928\" data-end=\"970\"\u003e\u003cstrong data-start=\"928\" data-end=\"944\"\u003eDriver Type:\u003c\/strong\u003e 1.25 mm hex hand driver\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"971\" data-end=\"1048\"\u003e\n\u003cp data-start=\"973\" data-end=\"996\"\u003e\u003cstrong data-start=\"973\" data-end=\"994\"\u003eAvailable Styles:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"999\" data-end=\"1048\"\u003e\n\u003cli data-start=\"999\" data-end=\"1023\"\u003e\n\u003cp data-start=\"1001\" data-end=\"1023\"\u003eClosed Tray Transfer\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1026\" data-end=\"1048\"\u003e\n\u003cp data-start=\"1028\" data-end=\"1048\"\u003eOpen Tray Transfer\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1049\" data-end=\"1092\"\u003e\n\u003cp data-start=\"1051\" data-end=\"1092\"\u003e\u003cstrong data-start=\"1051\" data-end=\"1060\"\u003eType:\u003c\/strong\u003e Impression Transfer Component\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1094\" data-end=\"1097\"\u003e\n\u003ch2 data-start=\"1099\" data-end=\"1129\"\u003e\u003cstrong data-start=\"1102\" data-end=\"1129\"\u003eKey Features \u0026amp; Benefits\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-start=\"1130\" data-end=\"1592\"\u003e\n\u003cli data-start=\"1130\" data-end=\"1224\"\u003e\n\u003cp data-start=\"1132\" data-end=\"1224\"\u003e\u003cstrong data-start=\"1132\" data-end=\"1163\"\u003ePrecise Impression Accuracy\u003c\/strong\u003e — Transfers implant position exactly to the working model.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1225\" data-end=\"1301\"\u003e\n\u003cp data-start=\"1227\" data-end=\"1301\"\u003e\u003cstrong data-start=\"1227\" data-end=\"1256\"\u003eSecure Conical Engagement\u003c\/strong\u003e — Stable seating reduces rotational error.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1302\" data-end=\"1397\"\u003e\n\u003cp data-start=\"1304\" data-end=\"1397\"\u003e\u003cstrong data-start=\"1304\" data-end=\"1336\"\u003eDual Technique Compatibility\u003c\/strong\u003e — Supports both open and closed tray impression protocols.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1398\" data-end=\"1495\"\u003e\n\u003cp data-start=\"1400\" data-end=\"1495\"\u003e\u003cstrong data-start=\"1400\" data-end=\"1424\"\u003eDurable Construction\u003c\/strong\u003e — Stainless steel body resists deformation and maintains tolerances.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1496\" data-end=\"1592\"\u003e\n\u003cp data-start=\"1498\" data-end=\"1592\"\u003e\u003cstrong data-start=\"1498\" data-end=\"1524\"\u003eLaboratory Reliability\u003c\/strong\u003e — Ensures consistent analog placement for prosthetic fabrication.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1594\" data-end=\"1597\"\u003e\n\u003ch2 data-start=\"1599\" data-end=\"1609\"\u003e\u003cstrong data-start=\"1602\" data-end=\"1609\"\u003eFAQ\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"1611\" data-end=\"1748\"\u003e\u003cstrong data-start=\"1611\" data-end=\"1649\"\u003eQ: What is this transfer used for?\u003c\/strong\u003e\u003cbr data-start=\"1649\" data-end=\"1652\"\u003eA: It transfers the intraoral implant position to the dental model during impression procedures.\u003c\/p\u003e\n\u003cp data-start=\"1750\" data-end=\"1856\"\u003e\u003cstrong data-start=\"1750\" data-end=\"1798\"\u003eQ: Can it be tightened with a torque wrench?\u003c\/strong\u003e\u003cbr data-start=\"1798\" data-end=\"1801\"\u003eA: No. It should be tightened manually only (5–10 Ncm).\u003c\/p\u003e\n\u003cp data-start=\"1858\" data-end=\"1961\"\u003e\u003cstrong data-start=\"1858\" data-end=\"1901\"\u003eQ: Which systems is it compatible with?\u003c\/strong\u003e\u003cbr data-start=\"1901\" data-end=\"1904\"\u003eA: All Alfa Gate Narrow Platform conical implant systems.\u003c\/p\u003e\n\u003cp data-start=\"1963\" data-end=\"2026\"\u003e\u003cstrong data-start=\"1963\" data-end=\"1994\"\u003eQ: What driver is required?\u003c\/strong\u003e\u003cbr data-start=\"1994\" data-end=\"1997\"\u003eA: A 1.25 mm hex hand driver.\u003c\/p\u003e","brand":"Alfa Gate","offers":[{"title":"Close Tray implant transfer \/ NARROW CONICAL PLATFORM \/ TRANSFERS","offer_id":43731440992508,"sku":"ITK-NP","price":30.0,"currency_code":"USD","in_stock":true},{"title":"Open tray implant transfer \/ NARROW CONICAL PLATFORM \/ TRANSFERS","offer_id":43731441025276,"sku":"ITC-NP","price":30.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0657\/2788\/9660\/products\/ITC-NP.png?v=1663140693"},{"product_id":"implant-transfer-rp","title":"Implant transfer RP","description":"\u003cp data-start=\"108\" data-end=\"435\"\u003eThe \u003cstrong data-start=\"112\" data-end=\"145\"\u003eAlfa Gate Implant Transfer RP\u003c\/strong\u003e is a precision impression coping designed for accurate implant position transfer in conventional impression workflows. Compatible with the \u003cstrong data-start=\"285\" data-end=\"318\"\u003eConical Regular Platform (RP)\u003c\/strong\u003e, it ensures reliable replication of implant orientation and depth from the clinical setting to the laboratory model.\u003c\/p\u003e\n\u003cp data-start=\"437\" data-end=\"540\"\u003eAvailable in \u003cstrong data-start=\"450\" data-end=\"465\"\u003eClosed Tray\u003c\/strong\u003e and \u003cstrong data-start=\"470\" data-end=\"483\"\u003eOpen Tray\u003c\/strong\u003e configurations to support different clinical techniques.\u003c\/p\u003e\n\u003chr data-start=\"542\" data-end=\"545\"\u003e\n\u003ch2 data-start=\"547\" data-end=\"574\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul data-start=\"576\" data-end=\"1013\"\u003e\n\u003cli data-start=\"576\" data-end=\"617\"\u003e\n\u003cp data-start=\"578\" data-end=\"617\"\u003e\u003cstrong data-start=\"578\" data-end=\"595\"\u003eProduct Name:\u003c\/strong\u003e Implant Transfer RP\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"618\" data-end=\"637\"\u003e\n\u003cp data-start=\"620\" data-end=\"637\"\u003e\u003cstrong data-start=\"620\" data-end=\"628\"\u003eSKU:\u003c\/strong\u003e ITK-RP \/ \u003cspan\u003eITC-RP\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"831\" data-end=\"862\"\u003e\n\u003cp data-start=\"833\" data-end=\"862\"\u003e\u003cstrong data-start=\"833\" data-end=\"852\"\u003eInterface size:\u003c\/strong\u003e 2.65 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"863\" data-end=\"881\"\u003e\n\u003cp data-start=\"865\" data-end=\"881\"\u003e\u003cstrong data-start=\"865\" data-end=\"875\"\u003eAngle:\u003c\/strong\u003e 22°\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"882\" data-end=\"964\"\u003e\n\u003cp data-start=\"884\" data-end=\"910\"\u003e\u003cstrong data-start=\"884\" data-end=\"908\"\u003eCompatible families:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"913\" data-end=\"964\"\u003e\n\u003cli data-start=\"913\" data-end=\"922\"\u003e\n\u003cp data-start=\"915\" data-end=\"922\"\u003eM+ RP\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"925\" data-end=\"964\"\u003e\n\u003cp data-start=\"927\" data-end=\"964\"\u003eOther RP conical systems (non-TRIO)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"700\" data-end=\"732\"\u003e\n\u003cp data-start=\"702\" data-end=\"732\"\u003e\u003cstrong data-start=\"702\" data-end=\"722\"\u003eConnection Type:\u003c\/strong\u003e Conical\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"733\" data-end=\"766\"\u003e\n\u003cp data-start=\"735\" data-end=\"766\"\u003e\u003cstrong data-start=\"735\" data-end=\"748\"\u003eMaterial:\u003c\/strong\u003e Stainless Steel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"767\" data-end=\"860\"\u003e\n\u003cp data-start=\"769\" data-end=\"792\"\u003e\u003cstrong data-start=\"769\" data-end=\"790\"\u003eAvailable Styles:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"795\" data-end=\"860\"\u003e\n\u003cli data-start=\"795\" data-end=\"827\"\u003e\n\u003cp data-start=\"797\" data-end=\"827\"\u003eClosed Tray Implant Transfer\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"830\" data-end=\"860\"\u003e\n\u003cp data-start=\"832\" data-end=\"860\"\u003eOpen Tray Implant Transfer\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"861\" data-end=\"896\"\u003e\n\u003cp data-start=\"863\" data-end=\"896\"\u003e\u003cstrong data-start=\"863\" data-end=\"874\"\u003eDriver:\u003c\/strong\u003e 1.25 mm Hand Driver\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"897\" data-end=\"968\"\u003e\n\u003cp data-start=\"899\" data-end=\"968\"\u003e\u003cstrong data-start=\"899\" data-end=\"922\"\u003eRecommended Torque:\u003c\/strong\u003e Manual only — light finger-tight (5–10 Ncm)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"969\" data-end=\"1013\"\u003e\n\u003cp data-start=\"971\" data-end=\"1013\"\u003e\u003cstrong data-start=\"971\" data-end=\"980\"\u003eType:\u003c\/strong\u003e Transfers \/ Impression Copings\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1015\" data-end=\"1018\"\u003e\n\u003ch2 data-start=\"1020\" data-end=\"1046\"\u003eKey Features \u0026amp; Benefits\u003c\/h2\u003e\n\u003cul data-start=\"1048\" data-end=\"1536\"\u003e\n\u003cli data-start=\"1048\" data-end=\"1143\"\u003e\n\u003cp data-start=\"1050\" data-end=\"1143\"\u003e\u003cstrong data-start=\"1050\" data-end=\"1087\"\u003eAccurate Implant Position Capture\u003c\/strong\u003e — Ensures precise transfer of 3D implant orientation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1144\" data-end=\"1234\"\u003e\n\u003cp data-start=\"1146\" data-end=\"1234\"\u003e\u003cstrong data-start=\"1146\" data-end=\"1182\"\u003eConical Connection Compatibility\u003c\/strong\u003e — Designed specifically for RP conical interface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1235\" data-end=\"1349\"\u003e\n\u003cp data-start=\"1237\" data-end=\"1349\"\u003e\u003cstrong data-start=\"1237\" data-end=\"1267\"\u003eHigh Dimensional Stability\u003c\/strong\u003e — Stainless steel construction resists distortion during impression procedures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1350\" data-end=\"1459\"\u003e\n\u003cp data-start=\"1352\" data-end=\"1459\"\u003e\u003cstrong data-start=\"1352\" data-end=\"1377\"\u003eTechnique Versatility\u003c\/strong\u003e — Supports both closed-tray (repositioning) and open-tray (pick-up) techniques.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1460\" data-end=\"1536\"\u003e\n\u003cp data-start=\"1462\" data-end=\"1536\"\u003e\u003cstrong data-start=\"1462\" data-end=\"1480\"\u003eSecure Seating\u003c\/strong\u003e — Stable engagement reduces risk of rotational error.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1538\" data-end=\"1541\"\u003e\n\u003ch2 data-start=\"1543\" data-end=\"1566\"\u003eClinical Indications\u003c\/h2\u003e\n\u003cul data-start=\"1568\" data-end=\"1729\"\u003e\n\u003cli data-start=\"1568\" data-end=\"1596\"\u003e\n\u003cp data-start=\"1570\" data-end=\"1596\"\u003eSingle-unit restorations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1597\" data-end=\"1631\"\u003e\n\u003cp data-start=\"1599\" data-end=\"1631\"\u003eMulti-unit prosthetic planning\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1632\" data-end=\"1664\"\u003e\n\u003cp data-start=\"1634\" data-end=\"1664\"\u003eCrown and bridge fabrication\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1665\" data-end=\"1696\"\u003e\n\u003cp data-start=\"1667\" data-end=\"1696\"\u003eAnalog impression workflows\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1697\" data-end=\"1729\"\u003e\n\u003cp data-start=\"1699\" data-end=\"1729\"\u003eLaboratory model fabrication\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1731\" data-end=\"1734\"\u003e\n\u003ch2 data-start=\"1736\" data-end=\"1763\"\u003eClosed Tray vs Open Tray\u003c\/h2\u003e\n\u003cp data-start=\"1765\" data-end=\"1789\"\u003e\u003cstrong data-start=\"1765\" data-end=\"1789\"\u003eClosed Tray Transfer\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1790\" data-end=\"1919\"\u003e\n\u003cli data-start=\"1790\" data-end=\"1822\"\u003e\n\u003cp data-start=\"1792\" data-end=\"1822\"\u003eSuitable for single implants\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1823\" data-end=\"1879\"\u003e\n\u003cp data-start=\"1825\" data-end=\"1879\"\u003eRequires repositioning into impression after removal\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1880\" data-end=\"1919\"\u003e\n\u003cp data-start=\"1882\" data-end=\"1919\"\u003eEfficient for straightforward cases\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1921\" data-end=\"1943\"\u003e\u003cstrong data-start=\"1921\" data-end=\"1943\"\u003eOpen Tray Transfer\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1944\" data-end=\"2089\"\u003e\n\u003cli data-start=\"1944\" data-end=\"1981\"\u003e\n\u003cp data-start=\"1946\" data-end=\"1981\"\u003eRecommended for multiple implants\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1982\" data-end=\"2034\"\u003e\n\u003cp data-start=\"1984\" data-end=\"2034\"\u003ePick-up technique for higher positional accuracy\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2035\" data-end=\"2089\"\u003e\n\u003cp data-start=\"2037\" data-end=\"2089\"\u003eIdeal for full-arch or parallelism-sensitive cases\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2091\" data-end=\"2094\"\u003e\n\u003ch2 data-start=\"2096\" data-end=\"2102\"\u003eFAQ\u003c\/h2\u003e\n\u003cp data-start=\"2104\" data-end=\"2229\"\u003e\u003cstrong data-start=\"2104\" data-end=\"2151\"\u003eQ: Can this transfer be torqued clinically?\u003c\/strong\u003e\u003cbr data-start=\"2151\" data-end=\"2154\"\u003eNo. It should be tightened manually (5–10 Ncm) using a 1.25 mm hand driver.\u003c\/p\u003e\n\u003cp data-start=\"2231\" data-end=\"2346\"\u003e\u003cstrong data-start=\"2231\" data-end=\"2272\"\u003eQ: Is it compatible with NP implants?\u003c\/strong\u003e\u003cbr data-start=\"2272\" data-end=\"2275\"\u003eNo. This version is specifically for the Conical Regular Platform (RP).\u003c\/p\u003e\n\u003cp data-start=\"2348\" data-end=\"2450\"\u003e\u003cstrong data-start=\"2348\" data-end=\"2377\"\u003eQ: What material is used?\u003c\/strong\u003e\u003cbr data-start=\"2377\" data-end=\"2380\"\u003eHigh-quality stainless steel for dimensional stability and durability.\u003c\/p\u003e","brand":"Alfa Gate","offers":[{"title":"CLOSE TRAY implant transfer \/ REGULAR CONICAL PLATFORM \/ TRANSFERS","offer_id":43731444465916,"sku":"ITK-RP","price":30.0,"currency_code":"USD","in_stock":true},{"title":"Open tray implant transfer \/ REGULAR CONICAL PLATFORM \/ TRANSFERS","offer_id":43731444498684,"sku":"ITC-RP","price":23.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0657\/2788\/9660\/products\/ITC-RP.png?v=1663141025"},{"product_id":"low-profile-connector-transfer-open-tray","title":"Low Profile Connector Transfer (Open Tray)","description":"\u003cp data-start=\"142\" data-end=\"610\"\u003eThe \u003cstrong data-start=\"146\" data-end=\"192\"\u003eLow Profile Connector Transfer (Open Tray)\u003c\/strong\u003e is a precision impression component designed for accurate implant position transfer using the open-tray impression technique. Manufactured from high-quality titanium, it ensures stable seating, precise indexing, and reliable impression capture, allowing clinicians and laboratories to achieve highly accurate prosthetic outcomes. Its extended height improves visibility and accessibility during impression procedures.\u003c\/p\u003e\n\u003chr data-start=\"612\" data-end=\"615\"\u003e\n\u003ch2 data-start=\"617\" data-end=\"644\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul data-start=\"645\" data-end=\"936\"\u003e\n\u003cli data-start=\"645\" data-end=\"666\"\u003e\n\u003cp data-start=\"647\" data-end=\"666\"\u003eHeight: \u003cstrong data-start=\"655\" data-end=\"664\"\u003e22 mm\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"645\" data-end=\"666\"\u003ePlatform:\u003cstrong data-start=\"655\" data-end=\"664\"\u003e SP \u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"667\" data-end=\"693\"\u003e\n\u003cp data-start=\"669\" data-end=\"693\"\u003eMaterial: \u003cstrong data-start=\"679\" data-end=\"691\"\u003eTitanium\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"694\" data-end=\"733\"\u003e\n\u003cp data-start=\"696\" data-end=\"733\"\u003eTechnique: \u003cstrong data-start=\"707\" data-end=\"731\"\u003eOpen tray impression\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"734\" data-end=\"783\"\u003e\n\u003cp data-start=\"736\" data-end=\"783\"\u003eDriver compatibility: \u003cstrong data-start=\"758\" data-end=\"781\"\u003e1.25 mm hand driver\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"784\" data-end=\"852\"\u003e\n\u003cp data-start=\"786\" data-end=\"852\"\u003eRecommended torque: \u003cstrong data-start=\"806\" data-end=\"850\"\u003eManual finger tightening only (5–10 Ncm)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"853\" data-end=\"892\"\u003e\n\u003cp data-start=\"855\" data-end=\"892\"\u003eComponent type: Impression transfer\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"893\" data-end=\"936\"\u003e\n\u003cp data-start=\"895\" data-end=\"936\"\u003eDesign: Low profile connector interface\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"938\" data-end=\"941\"\u003e\n\u003ch2 data-start=\"943\" data-end=\"969\"\u003eKey Features \u0026amp; Benefits\u003c\/h2\u003e\n\u003cul data-start=\"970\" data-end=\"1266\"\u003e\n\u003cli data-start=\"970\" data-end=\"1030\"\u003e\n\u003cp data-start=\"972\" data-end=\"1030\"\u003ePrecise implant position transfer to impression material\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1031\" data-end=\"1095\"\u003e\n\u003cp data-start=\"1033\" data-end=\"1095\"\u003eHigh-strength titanium construction for dimensional accuracy\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1096\" data-end=\"1150\"\u003e\n\u003cp data-start=\"1098\" data-end=\"1150\"\u003eExtended body for improved handling and visibility\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1151\" data-end=\"1216\"\u003e\n\u003cp data-start=\"1153\" data-end=\"1216\"\u003eStable seating minimizes distortion during impression removal\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1217\" data-end=\"1266\"\u003e\n\u003cp data-start=\"1219\" data-end=\"1266\"\u003eDesigned for predictable prosthetic workflows\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1268\" data-end=\"1271\"\u003e\n\u003ch2 data-start=\"1273\" data-end=\"1302\"\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp data-start=\"1304\" data-end=\"1429\"\u003e\u003cstrong data-start=\"1304\" data-end=\"1352\"\u003eQ: What technique is this transfer used for?\u003c\/strong\u003e\u003cbr data-start=\"1352\" data-end=\"1355\"\u003eA: It is designed specifically for the \u003cstrong data-start=\"1394\" data-end=\"1428\"\u003eopen tray impression technique\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"1431\" data-end=\"1575\"\u003e\u003cstrong data-start=\"1431\" data-end=\"1469\"\u003eQ: Why choose open tray transfers?\u003c\/strong\u003e\u003cbr data-start=\"1469\" data-end=\"1472\"\u003eA: They provide highly accurate implant position recording, especially for multiple or angled implants.\u003c\/p\u003e\n\u003cp data-start=\"1577\" data-end=\"1671\"\u003e\u003cstrong data-start=\"1577\" data-end=\"1615\"\u003eQ: How tight should it be secured?\u003c\/strong\u003e\u003cbr data-start=\"1615\" data-end=\"1618\"\u003eA: Only light manual tightening between \u003cstrong data-start=\"1658\" data-end=\"1670\"\u003e5–10 Ncm\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"1673\" data-end=\"1737\"\u003e\u003cstrong data-start=\"1673\" data-end=\"1705\"\u003eQ: Which driver is required?\u003c\/strong\u003e\u003cbr data-start=\"1705\" data-end=\"1708\"\u003eA: A \u003cstrong data-start=\"1713\" data-end=\"1736\"\u003e1.25 mm hand driver\u003c\/strong\u003e.\u003c\/p\u003e","brand":"Alfa Gate","offers":[{"title":"SP PLATFORM \/ TRANSFERS","offer_id":43754013491452,"sku":"AGM-301-F","price":18.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0657\/2788\/9660\/products\/AGM-301-F.png?v=1663155515"},{"product_id":"single-unit-transfer-open-tray","title":"Single unit Transfer (Open Tray)","description":"\u003cp data-start=\"148\" data-end=\"544\"\u003eThe \u003cstrong data-start=\"152\" data-end=\"188\"\u003eSingle Unit Transfer (Open Tray)\u003c\/strong\u003e is a precision impression component designed to accurately transfer implant position from the oral cavity to the working model. Manufactured from high-quality stainless steel, it ensures stable fixation during open-tray impression procedures, allowing clinicians and technicians to achieve precise prosthetic positioning and reliable restorative outcomes.\u003c\/p\u003e\n\u003ch3 data-start=\"546\" data-end=\"574\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul data-start=\"575\" data-end=\"778\"\u003e\n\u003cli data-start=\"575\" data-end=\"614\"\u003e\n\u003cp data-start=\"577\" data-end=\"614\"\u003eType: Open-tray impression transfer\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"615\" data-end=\"632\"\u003e\n\u003cp data-start=\"617\" data-end=\"632\"\u003eHeight: 22 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"633\" data-end=\"676\"\u003e\n\u003cp data-start=\"635\" data-end=\"676\"\u003eMaterial: Medical-grade stainless steel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"677\" data-end=\"722\"\u003e\n\u003cp data-start=\"679\" data-end=\"722\"\u003eDriver compatibility: 1.25 mm hand driver\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"723\" data-end=\"778\"\u003e\n\u003cp data-start=\"725\" data-end=\"778\"\u003eRecommended torque: Manual tightening only (5–10 Ncm)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"780\" data-end=\"807\"\u003eKey Features \u0026amp; Benefits\u003c\/h3\u003e\n\u003cul data-start=\"808\" data-end=\"1112\"\u003e\n\u003cli data-start=\"808\" data-end=\"870\"\u003e\n\u003cp data-start=\"810\" data-end=\"870\"\u003eAccurate implant position transfer for precise impressions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"871\" data-end=\"918\"\u003e\n\u003cp data-start=\"873\" data-end=\"918\"\u003eStable retention within impression material\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"919\" data-end=\"973\"\u003e\n\u003cp data-start=\"921\" data-end=\"973\"\u003eHigh mechanical strength and dimensional stability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"974\" data-end=\"1011\"\u003e\n\u003cp data-start=\"976\" data-end=\"1011\"\u003eEasy manual placement and removal\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1012\" data-end=\"1061\"\u003e\n\u003cp data-start=\"1014\" data-end=\"1061\"\u003eDesigned for predictable prosthetic workflows\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1062\" data-end=\"1112\"\u003e\n\u003cp data-start=\"1064\" data-end=\"1112\"\u003eSupports reliable laboratory model fabrication\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1114\" data-end=\"1144\"\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp data-start=\"1146\" data-end=\"1313\"\u003e\u003cstrong data-start=\"1146\" data-end=\"1192\"\u003eQ: What is an open tray transfer used for?\u003c\/strong\u003e\u003cbr data-start=\"1192\" data-end=\"1195\"\u003eA: It captures the exact implant position during impression taking, allowing accurate replication in the dental model.\u003c\/p\u003e\n\u003cp data-start=\"1315\" data-end=\"1433\"\u003e\u003cstrong data-start=\"1315\" data-end=\"1363\"\u003eQ: Should torque be applied when tightening?\u003c\/strong\u003e\u003cbr data-start=\"1363\" data-end=\"1366\"\u003eA: Only light manual tightening is required to secure the transfer.\u003c\/p\u003e\n\u003cp data-start=\"1435\" data-end=\"1549\"\u003e\u003cstrong data-start=\"1435\" data-end=\"1479\"\u003eQ: Is it compatible with torque drivers?\u003c\/strong\u003e\u003cbr data-start=\"1479\" data-end=\"1482\"\u003eA: It is intended for manual placement using a 1.25 mm hand driver.\u003c\/p\u003e","brand":"Alfa Gate","offers":[{"title":"SP PLATFORM \/ Single Unit \/ ANALOGS","offer_id":43754102358268,"sku":"AGM-301-H","price":18.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0657\/2788\/9660\/products\/AGM-301-H.png?v=1663157152"},{"product_id":"multi-unit-transfer-open-tray","title":"Multi-Unit Transfer open tray","description":"\u003cp data-start=\"268\" data-end=\"466\"\u003eThe\u003cstrong\u003e Alfa Gate Multi-Unit Transfer Open Tray \u003c\/strong\u003eis designed for highly accurate implant-level impressions, enabling precise transfer of multi-unit abutment positions from the mouth to the working model.\u003c\/p\u003e\n\u003chr data-start=\"468\" data-end=\"471\"\u003e\n\u003ch3 data-start=\"473\" data-end=\"503\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul data-start=\"505\" data-end=\"939\"\u003e\n\u003cli data-start=\"505\" data-end=\"561\"\u003e\n\u003cp data-start=\"507\" data-end=\"561\"\u003e\u003cstrong data-start=\"507\" data-end=\"516\"\u003eType:\u003c\/strong\u003e Multi-Unit Impression Transfer (Open Tray)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"562\" data-end=\"583\"\u003e\n\u003cp data-start=\"564\" data-end=\"583\"\u003e\u003cstrong data-start=\"564\" data-end=\"575\"\u003eHeight:\u003c\/strong\u003e 22 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"584\" data-end=\"631\"\u003e\n\u003cp data-start=\"586\" data-end=\"631\"\u003e\u003cstrong data-start=\"586\" data-end=\"599\"\u003eMaterial:\u003c\/strong\u003e Medical-grade Stainless Steel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"632\" data-end=\"766\"\u003e\n\u003cp data-start=\"634\" data-end=\"661\"\u003e\u003cstrong data-start=\"634\" data-end=\"659\"\u003eCompatible Platforms:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"664\" data-end=\"766\"\u003e\n\u003cli data-start=\"664\" data-end=\"706\"\u003e\n\u003cp data-start=\"666\" data-end=\"706\"\u003e\u003cstrong data-start=\"666\" data-end=\"681\"\u003eSP Platform\u003c\/strong\u003e — Internal hex 2.42 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"709\" data-end=\"766\"\u003e\n\u003cp data-start=\"711\" data-end=\"766\"\u003e\u003cstrong data-start=\"711\" data-end=\"738\"\u003eRC Platform (TRIO only)\u003c\/strong\u003e — Morse taper 11°, 2.5 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"767\" data-end=\"803\"\u003e\n\u003cp data-start=\"769\" data-end=\"803\"\u003e\u003cstrong data-start=\"769\" data-end=\"795\"\u003eTorque Recommendation:\u003c\/strong\u003e 5 Ncm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"804\" data-end=\"838\"\u003e\n\u003cp data-start=\"806\" data-end=\"838\"\u003e\u003cstrong data-start=\"806\" data-end=\"817\"\u003eDriver:\u003c\/strong\u003e 1.25 mm hex driver\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"839\" data-end=\"888\"\u003e\n\u003cp data-start=\"841\" data-end=\"888\"\u003e\u003cstrong data-start=\"841\" data-end=\"855\"\u003eTechnique:\u003c\/strong\u003e Open tray impression technique\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"889\" data-end=\"939\"\u003e\n\u003cp data-start=\"891\" data-end=\"939\"\u003e\u003cstrong data-start=\"891\" data-end=\"899\"\u003eUse:\u003c\/strong\u003e Multi-unit and full-arch restorations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"941\" data-end=\"944\"\u003e\n\u003ch3 data-start=\"946\" data-end=\"975\"\u003eKey Features \u0026amp; Benefits\u003c\/h3\u003e\n\u003cul data-start=\"977\" data-end=\"1275\"\u003e\n\u003cli data-start=\"977\" data-end=\"1038\"\u003e\n\u003cp data-start=\"979\" data-end=\"1038\"\u003eProvides maximum impression accuracy for multi-unit cases\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1039\" data-end=\"1083\"\u003e\n\u003cp data-start=\"1041\" data-end=\"1083\"\u003eDesigned for open tray pick-up technique\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1084\" data-end=\"1135\"\u003e\n\u003cp data-start=\"1086\" data-end=\"1135\"\u003eEnsures stable seating during impression taking\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1136\" data-end=\"1182\"\u003e\n\u003cp data-start=\"1138\" data-end=\"1182\"\u003eHigh-strength stainless steel construction\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1183\" data-end=\"1218\"\u003e\n\u003cp data-start=\"1185\" data-end=\"1218\"\u003eMinimizes positional distortion\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1219\" data-end=\"1275\"\u003e\n\u003cp data-start=\"1221\" data-end=\"1275\"\u003eIdeal for full-arch and complex prosthetic workflows\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1277\" data-end=\"1280\"\u003e\n\u003ch3 data-start=\"1282\" data-end=\"1314\"\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp data-start=\"1316\" data-end=\"1453\"\u003e\u003cstrong data-start=\"1316\" data-end=\"1364\"\u003eQ1: When should I use an open tray transfer?\u003c\/strong\u003e\u003cbr data-start=\"1364\" data-end=\"1367\"\u003eWhen maximum accuracy is required, especially in multi-unit or full-arch restorations.\u003c\/p\u003e\n\u003cp data-start=\"1455\" data-end=\"1523\"\u003e\u003cstrong data-start=\"1455\" data-end=\"1487\"\u003eQ2: What torque is required?\u003c\/strong\u003e\u003cbr data-start=\"1487\" data-end=\"1490\"\u003e5 Ncm using a 1.25 mm hex driver.\u003c\/p\u003e\n\u003cp data-start=\"1525\" data-end=\"1666\"\u003e\u003cstrong data-start=\"1525\" data-end=\"1582\"\u003eQ3: What is the advantage over closed tray transfers?\u003c\/strong\u003e\u003cbr data-start=\"1582\" data-end=\"1585\"\u003eOpen tray transfers reduce repositioning errors and improve impression precision.\u003c\/p\u003e\n\u003cp data-start=\"1668\" data-end=\"1769\"\u003e\u003cstrong data-start=\"1668\" data-end=\"1714\"\u003eQ4: Which platforms is it compatible with?\u003c\/strong\u003e\u003cbr data-start=\"1714\" data-end=\"1717\"\u003eSP internal hex systems and TRIO RC conical systems.\u003c\/p\u003e","brand":"Alfa Gate","offers":[{"title":"SP PLATFORM \/ MULTI-UNIT","offer_id":43754027942140,"sku":"AGM-508","price":18.0,"currency_code":"USD","in_stock":true},{"title":"RC PLATFORM \/ MULTI-UNIT","offer_id":46423803101436,"sku":"AGM-508","price":18.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0657\/2788\/9660\/products\/AGM-508.png?v=1663160154"},{"product_id":"copy-of-multi-unit-transfer-open-trayhg","title":"Multi-Unit analog","description":"\u003cp\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003eThe \u003cstrong\u003eAlfa Gate Multi-Unit Analog \u003c\/strong\u003eis designed for precise laboratory model fabrication, accurately replicating the position and orientation of multi-unit abutments within the working cast.\u003c\/span\u003e\u003c\/p\u003e\n\u003chr data-start=\"443\" data-end=\"446\"\u003e\n\u003ch3 data-start=\"448\" data-end=\"478\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul data-start=\"480\" data-end=\"863\"\u003e\n\u003cli data-start=\"480\" data-end=\"522\"\u003e\n\u003cp data-start=\"482\" data-end=\"522\"\u003e\u003cstrong data-start=\"482\" data-end=\"491\"\u003eType:\u003c\/strong\u003e Multi-Unit Laboratory Analog\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"523\" data-end=\"544\"\u003e\n\u003cp data-start=\"525\" data-end=\"544\"\u003e\u003cstrong data-start=\"525\" data-end=\"536\"\u003eHeight:\u003c\/strong\u003e 12 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"545\" data-end=\"592\"\u003e\n\u003cp data-start=\"547\" data-end=\"592\"\u003e\u003cstrong data-start=\"547\" data-end=\"560\"\u003eMaterial:\u003c\/strong\u003e Medical-grade Stainless Steel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"593\" data-end=\"727\"\u003e\n\u003cp data-start=\"595\" data-end=\"622\"\u003e\u003cstrong data-start=\"595\" data-end=\"620\"\u003eCompatible Platforms:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"625\" data-end=\"727\"\u003e\n\u003cli data-start=\"625\" data-end=\"667\"\u003e\n\u003cp data-start=\"627\" data-end=\"667\"\u003e\u003cstrong data-start=\"627\" data-end=\"642\"\u003eSP Platform\u003c\/strong\u003e — Internal hex 2.42 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"670\" data-end=\"727\"\u003e\n\u003cp data-start=\"672\" data-end=\"727\"\u003e\u003cstrong data-start=\"672\" data-end=\"699\"\u003eRC Platform (TRIO ONLY)\u003c\/strong\u003e — Morse taper 11°, 2.5 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"728\" data-end=\"761\"\u003e\n\u003cp data-start=\"730\" data-end=\"761\"\u003e\u003cstrong data-start=\"730\" data-end=\"753\"\u003eRecommended Torque:\u003c\/strong\u003e 5 Ncm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"762\" data-end=\"796\"\u003e\n\u003cp data-start=\"764\" data-end=\"796\"\u003e\u003cstrong data-start=\"764\" data-end=\"775\"\u003eDriver:\u003c\/strong\u003e 1.25 mm hex driver\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"797\" data-end=\"863\"\u003e\n\u003cp data-start=\"799\" data-end=\"863\"\u003e\u003cstrong data-start=\"799\" data-end=\"815\"\u003eApplication:\u003c\/strong\u003e Model fabrication for multi-unit restorations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"865\" data-end=\"868\"\u003e\n\u003ch3 data-start=\"870\" data-end=\"899\"\u003eKey Features \u0026amp; Benefits\u003c\/h3\u003e\n\u003cul data-start=\"901\" data-end=\"1239\"\u003e\n\u003cli data-start=\"901\" data-end=\"966\"\u003e\n\u003cp data-start=\"903\" data-end=\"966\"\u003eEnsures precise reproduction of intraoral multi-unit position\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"967\" data-end=\"1025\"\u003e\n\u003cp data-start=\"969\" data-end=\"1025\"\u003eHigh dimensional accuracy for passive-fit restorations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1026\" data-end=\"1060\"\u003e\n\u003cp data-start=\"1028\" data-end=\"1060\"\u003eStable seating in stone models\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1061\" data-end=\"1122\"\u003e\n\u003cp data-start=\"1063\" data-end=\"1122\"\u003eDurable stainless steel construction for repeated lab use\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1123\" data-end=\"1176\"\u003e\n\u003cp data-start=\"1125\" data-end=\"1176\"\u003eCompatible with SP and TRIO RC multi-unit systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1177\" data-end=\"1239\"\u003e\n\u003cp data-start=\"1179\" data-end=\"1239\"\u003eEssential component for full-arch and multi-unit workflows\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1241\" data-end=\"1244\"\u003e\n\u003ch3 data-start=\"1246\" data-end=\"1278\"\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp data-start=\"1280\" data-end=\"1404\"\u003e\u003cstrong data-start=\"1280\" data-end=\"1332\"\u003eQ1: What is the function of a multi-unit analog?\u003c\/strong\u003e\u003cbr data-start=\"1332\" data-end=\"1335\"\u003eIt replicates the multi-unit abutment position in a laboratory model.\u003c\/p\u003e\n\u003cp data-start=\"1406\" data-end=\"1510\"\u003e\u003cstrong data-start=\"1406\" data-end=\"1430\"\u003eQ2: When is it used?\u003c\/strong\u003e\u003cbr data-start=\"1430\" data-end=\"1433\"\u003eDuring impression pouring and digital or conventional prosthetic fabrication.\u003c\/p\u003e\n\u003cp data-start=\"1512\" data-end=\"1580\"\u003e\u003cstrong data-start=\"1512\" data-end=\"1544\"\u003eQ3: What torque is required?\u003c\/strong\u003e\u003cbr data-start=\"1544\" data-end=\"1547\"\u003e5 Ncm using a 1.25 mm hex driver.\u003c\/p\u003e\n\u003cp data-start=\"1582\" data-end=\"1700\"\u003e\u003cstrong data-start=\"1582\" data-end=\"1636\"\u003eQ4: Is it compatible with all Alfa Gate platforms?\u003c\/strong\u003e\u003cbr data-start=\"1636\" data-end=\"1639\"\u003eIt is compatible with SP and TRIO RC multi-unit systems only.\u003c\/p\u003e","brand":"Alfa Gate","offers":[{"title":"SP PLATFORM \/ MULTI-UNIT","offer_id":43754018504956,"sku":"AGM-507","price":19.9,"currency_code":"USD","in_stock":true},{"title":"RC PLATFORM \/ MULTI-UNIT","offer_id":46423803265276,"sku":"AGM-507","price":19.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0657\/2788\/9660\/products\/AGM-507.png?v=1663160224"},{"product_id":"transfer-with-click-connection-close-tray","title":"Transfer with Click Connection (Close Tray)","description":"\u003cp data-start=\"72\" data-end=\"257\"\u003eThe \u003cstrong data-start=\"76\" data-end=\"134\"\u003eAlfa Gate Transfer with Click Connection (Closed Tray)\u003c\/strong\u003e is engineered for indirect impression procedures where secure implant engagement and accurate repositioning are essential.\u003c\/p\u003e\n\u003cp data-start=\"259\" data-end=\"522\"\u003eThe click connection mechanism ensures stable seating on the implant, minimizing rotational movement during impression taking. Manufactured from \u003cstrong data-start=\"404\" data-end=\"423\"\u003estainless steel\u003c\/strong\u003e, this component offers high dimensional stability and durability for reliable laboratory outcomes.\u003c\/p\u003e\n\u003chr data-start=\"524\" data-end=\"527\"\u003e\n\u003ch3 data-start=\"529\" data-end=\"559\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul data-start=\"560\" data-end=\"820\"\u003e\n\u003cli data-start=\"560\" data-end=\"601\"\u003e\n\u003cp data-start=\"562\" data-end=\"601\"\u003e\u003cstrong data-start=\"562\" data-end=\"576\"\u003eTechnique:\u003c\/strong\u003e Closed tray (indirect)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"602\" data-end=\"643\"\u003e\n\u003cp data-start=\"604\" data-end=\"643\"\u003e\u003cstrong data-start=\"604\" data-end=\"624\"\u003eConnection type:\u003c\/strong\u003e Click connection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"644\" data-end=\"665\"\u003e\n\u003cp data-start=\"646\" data-end=\"665\"\u003e\u003cstrong data-start=\"646\" data-end=\"657\"\u003eHeight:\u003c\/strong\u003e 11 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"666\" data-end=\"699\"\u003e\n\u003cp data-start=\"668\" data-end=\"699\"\u003e\u003cstrong data-start=\"668\" data-end=\"681\"\u003eMaterial:\u003c\/strong\u003e Stainless Steel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"700\" data-end=\"770\"\u003e\n\u003cp data-start=\"702\" data-end=\"770\"\u003e\u003cstrong data-start=\"702\" data-end=\"725\"\u003eRecommended torque:\u003c\/strong\u003e 5–10 Ncm (manual, light finger-tight only)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"771\" data-end=\"820\"\u003e\n\u003cp data-start=\"773\" data-end=\"820\"\u003e\u003cstrong data-start=\"773\" data-end=\"798\"\u003eDriver compatibility:\u003c\/strong\u003e 1.25 mm hand driver\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"822\" data-end=\"825\"\u003e\n\u003ch3 data-start=\"827\" data-end=\"865\"\u003eKey Features \u0026amp; Clinical Benefits\u003c\/h3\u003e\n\u003cul data-start=\"866\" data-end=\"1140\"\u003e\n\u003cli data-start=\"866\" data-end=\"916\"\u003e\n\u003cp data-start=\"868\" data-end=\"916\"\u003eClick connection for secure implant engagement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"917\" data-end=\"967\"\u003e\n\u003cp data-start=\"919\" data-end=\"967\"\u003eStable positioning during impression procedure\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"968\" data-end=\"1029\"\u003e\n\u003cp data-start=\"970\" data-end=\"1029\"\u003eStainless steel construction for precision and durability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1030\" data-end=\"1078\"\u003e\n\u003cp data-start=\"1032\" data-end=\"1078\"\u003eControlled manual torque protocol (5–10 Ncm)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1079\" data-end=\"1140\"\u003e\n\u003cp data-start=\"1081\" data-end=\"1140\"\u003eAccurate transfer of implant position to the master model\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1142\" data-end=\"1145\"\u003e\n\u003ch3 data-start=\"1147\" data-end=\"1170\"\u003eClinical Workflow\u003c\/h3\u003e\n\u003col data-start=\"1171\" data-end=\"1458\"\u003e\n\u003cli data-start=\"1171\" data-end=\"1245\"\u003e\n\u003cp data-start=\"1174\" data-end=\"1245\"\u003eSeat the transfer onto the implant until the click mechanism engages.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1246\" data-end=\"1312\"\u003e\n\u003cp data-start=\"1249\" data-end=\"1312\"\u003eTighten manually using a 1.25 mm hand driver (5–10 Ncm only).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1313\" data-end=\"1350\"\u003e\n\u003cp data-start=\"1316\" data-end=\"1350\"\u003eTake the closed tray impression.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1351\" data-end=\"1458\"\u003e\n\u003cp data-start=\"1354\" data-end=\"1458\"\u003eAfter removal, detach the transfer and reposition it into the impression before laboratory processing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003chr data-start=\"1460\" data-end=\"1463\"\u003e\n\u003ch3 data-start=\"1465\" data-end=\"1474\"\u003eFAQ\u003c\/h3\u003e\n\u003cp data-start=\"1476\" data-end=\"1569\"\u003e\u003cstrong data-start=\"1476\" data-end=\"1522\"\u003eWhich technique is this transfer used for?\u003c\/strong\u003e\u003cbr data-start=\"1522\" data-end=\"1525\"\u003eClosed tray (indirect) impression technique.\u003c\/p\u003e\n\u003cp data-start=\"1571\" data-end=\"1641\"\u003e\u003cstrong data-start=\"1571\" data-end=\"1605\"\u003eWhat torque should be applied?\u003c\/strong\u003e\u003cbr data-start=\"1605\" data-end=\"1608\"\u003eManual tightening only, 5–10 Ncm.\u003c\/p\u003e\n\u003cp data-start=\"1643\" data-end=\"1695\"\u003e\u003cstrong data-start=\"1643\" data-end=\"1672\"\u003eWhich driver is required?\u003c\/strong\u003e\u003cbr data-start=\"1672\" data-end=\"1675\"\u003e1.25 mm hand driver.\u003c\/p\u003e\n\u003cp data-start=\"1697\" data-end=\"1748\"\u003e\u003cstrong data-start=\"1697\" data-end=\"1729\"\u003eWhat material is it made of?\u003c\/strong\u003e\u003cbr data-start=\"1729\" data-end=\"1732\"\u003eStainless steel.\u003c\/p\u003e","brand":"Alfa Gate","offers":[{"title":"SP PLATFORM \/ TRANSFERS","offer_id":43754185982204,"sku":"AGM-302","price":30.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0657\/2788\/9660\/products\/AGM-302.png?v=1663162653"},{"product_id":"transfer-concave-with-click-connection-close-tray","title":"Transfer Concave with Click Connection (Close Tray)","description":"\u003cp data-start=\"80\" data-end=\"267\"\u003eThe \u003cstrong data-start=\"84\" data-end=\"150\"\u003eAlfa Gate Transfer Concave with Click Connection (Closed Tray)\u003c\/strong\u003e is designed for indirect (closed tray) impression procedures requiring enhanced retention and precise repositioning.\u003c\/p\u003e\n\u003cp data-start=\"269\" data-end=\"460\"\u003eThe concave body geometry improves mechanical interlocking with impression material, while the click connection ensures stable and secure seating on the implant during the impression process.\u003c\/p\u003e\n\u003cp data-start=\"462\" data-end=\"608\"\u003eManufactured from \u003cstrong data-start=\"480\" data-end=\"499\"\u003estainless steel\u003c\/strong\u003e, this transfer provides dimensional stability and long-term durability in clinical and laboratory workflows.\u003c\/p\u003e\n\u003chr data-start=\"610\" data-end=\"613\"\u003e\n\u003ch3 data-start=\"615\" data-end=\"645\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul data-start=\"646\" data-end=\"906\"\u003e\n\u003cli data-start=\"646\" data-end=\"687\"\u003e\n\u003cp data-start=\"648\" data-end=\"687\"\u003e\u003cstrong data-start=\"648\" data-end=\"662\"\u003eTechnique:\u003c\/strong\u003e Closed tray (indirect)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"646\" data-end=\"687\"\u003e\n\u003cstrong\u003ePlatform:\u003c\/strong\u003e SP Platform \u003c\/li\u003e\n\u003cli data-start=\"688\" data-end=\"729\"\u003e\n\u003cp data-start=\"690\" data-end=\"729\"\u003e\u003cstrong data-start=\"690\" data-end=\"710\"\u003eConnection type:\u003c\/strong\u003e Click connection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"730\" data-end=\"751\"\u003e\n\u003cp data-start=\"732\" data-end=\"751\"\u003e\u003cstrong data-start=\"732\" data-end=\"743\"\u003eHeight:\u003c\/strong\u003e 11 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"752\" data-end=\"785\"\u003e\n\u003cp data-start=\"754\" data-end=\"785\"\u003e\u003cstrong data-start=\"754\" data-end=\"767\"\u003eMaterial:\u003c\/strong\u003e Stainless Steel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"786\" data-end=\"856\"\u003e\n\u003cp data-start=\"788\" data-end=\"856\"\u003e\u003cstrong data-start=\"788\" data-end=\"811\"\u003eRecommended torque:\u003c\/strong\u003e 5–10 Ncm (manual, light finger-tight only)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"857\" data-end=\"906\"\u003e\n\u003cp data-start=\"859\" data-end=\"906\"\u003e\u003cstrong data-start=\"859\" data-end=\"884\"\u003eDriver compatibility:\u003c\/strong\u003e 1.25 mm hand driver\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"908\" data-end=\"911\"\u003e\n\u003ch3 data-start=\"913\" data-end=\"951\"\u003eKey Features \u0026amp; Clinical Benefits\u003c\/h3\u003e\n\u003cul data-start=\"952\" data-end=\"1241\"\u003e\n\u003cli data-start=\"952\" data-end=\"1002\"\u003e\n\u003cp data-start=\"954\" data-end=\"1002\"\u003eClick connection for stable implant engagement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1003\" data-end=\"1069\"\u003e\n\u003cp data-start=\"1005\" data-end=\"1069\"\u003eConcave body design for improved impression material retention\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1070\" data-end=\"1131\"\u003e\n\u003cp data-start=\"1072\" data-end=\"1131\"\u003eStainless steel construction for precision and durability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1132\" data-end=\"1180\"\u003e\n\u003cp data-start=\"1134\" data-end=\"1180\"\u003eControlled manual torque protocol (5–10 Ncm)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1181\" data-end=\"1241\"\u003e\n\u003cp data-start=\"1183\" data-end=\"1241\"\u003eAccurate transfer of implant position to the master cast\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1243\" data-end=\"1246\"\u003e\n\u003ch3 data-start=\"1248\" data-end=\"1271\"\u003eClinical Workflow\u003c\/h3\u003e\n\u003col data-start=\"1272\" data-end=\"1571\"\u003e\n\u003cli data-start=\"1272\" data-end=\"1347\"\u003e\n\u003cp data-start=\"1275\" data-end=\"1347\"\u003eSeat the transfer onto the implant until the click connection engages.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1348\" data-end=\"1414\"\u003e\n\u003cp data-start=\"1351\" data-end=\"1414\"\u003eTighten manually using a 1.25 mm hand driver (5–10 Ncm only).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1415\" data-end=\"1452\"\u003e\n\u003cp data-start=\"1418\" data-end=\"1452\"\u003eTake the closed tray impression.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1453\" data-end=\"1571\"\u003e\n\u003cp data-start=\"1456\" data-end=\"1571\"\u003eAfter impression removal, detach the transfer and reposition it into the impression before laboratory processing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003chr data-start=\"1573\" data-end=\"1576\"\u003e\n\u003ch3 data-start=\"1578\" data-end=\"1587\"\u003eFAQ\u003c\/h3\u003e\n\u003cp data-start=\"1589\" data-end=\"1673\"\u003e\u003cstrong data-start=\"1589\" data-end=\"1637\"\u003eWhich impression technique is this used for?\u003c\/strong\u003e\u003cbr data-start=\"1637\" data-end=\"1640\"\u003eClosed tray (indirect) technique.\u003c\/p\u003e\n\u003cp data-start=\"1675\" data-end=\"1745\"\u003e\u003cstrong data-start=\"1675\" data-end=\"1709\"\u003eWhat torque should be applied?\u003c\/strong\u003e\u003cbr data-start=\"1709\" data-end=\"1712\"\u003eManual tightening only, 5–10 Ncm.\u003c\/p\u003e\n\u003cp data-start=\"1747\" data-end=\"1799\"\u003e\u003cstrong data-start=\"1747\" data-end=\"1776\"\u003eWhich driver is required?\u003c\/strong\u003e\u003cbr data-start=\"1776\" data-end=\"1779\"\u003e1.25 mm hand driver.\u003c\/p\u003e\n\u003cp data-start=\"1801\" data-end=\"1845\"\u003e\u003cstrong data-start=\"1801\" data-end=\"1826\"\u003eWhat is the material?\u003c\/strong\u003e\u003cbr data-start=\"1826\" data-end=\"1829\"\u003eStainless steel.\u003c\/p\u003e","brand":"Alfa Gate","offers":[{"title":"SP PLATFORM \/ TRANSFERS","offer_id":43754183819516,"sku":"AGM-302-C","price":30.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0657\/2788\/9660\/products\/AGM-302-C.png?v=1663162777"},{"product_id":"transfer-with-screw-connection-close-tray","title":"Transfer with Screw Connection (Closed Tray)","description":"\u003cp data-start=\"74\" data-end=\"229\"\u003eThe \u003cstrong data-start=\"78\" data-end=\"136\"\u003eAlfa Gate Transfer with Screw Connection (Closed Tray)\u003c\/strong\u003e is designed for accurate indirect impression procedures using a screw-retained connection.\u003c\/p\u003e\n\u003cp data-start=\"231\" data-end=\"454\"\u003eManufactured from \u003cstrong data-start=\"249\" data-end=\"268\"\u003estainless steel\u003c\/strong\u003e, this transfer ensures secure seating on the implant and stable positioning during impression taking, allowing precise reproduction of the implant’s 3D orientation in the working model.\u003c\/p\u003e\n\u003chr data-start=\"456\" data-end=\"459\"\u003e\n\u003ch3 data-start=\"461\" data-end=\"491\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul data-start=\"492\" data-end=\"758\"\u003e\n\u003cli data-start=\"492\" data-end=\"533\"\u003e\n\u003cp data-start=\"494\" data-end=\"533\"\u003e\u003cstrong data-start=\"494\" data-end=\"508\"\u003eTechnique:\u003c\/strong\u003e Closed tray (indirect)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"534\" data-end=\"582\"\u003e\n\u003cp data-start=\"536\" data-end=\"582\"\u003e\u003cstrong data-start=\"536\" data-end=\"556\"\u003eConnection type:\u003c\/strong\u003e Screw-retained transfer\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"583\" data-end=\"603\"\u003e\n\u003cp data-start=\"585\" data-end=\"603\"\u003e\u003cstrong data-start=\"585\" data-end=\"596\"\u003eHeight:\u003c\/strong\u003e 8 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"604\" data-end=\"637\"\u003e\n\u003cp data-start=\"606\" data-end=\"637\"\u003e\u003cstrong data-start=\"606\" data-end=\"619\"\u003eMaterial:\u003c\/strong\u003e Stainless Steel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"638\" data-end=\"708\"\u003e\n\u003cp data-start=\"640\" data-end=\"708\"\u003e\u003cstrong data-start=\"640\" data-end=\"663\"\u003eRecommended torque:\u003c\/strong\u003e 5–10 Ncm (manual, light finger-tight only)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"709\" data-end=\"758\"\u003e\n\u003cp data-start=\"711\" data-end=\"758\"\u003e\u003cstrong data-start=\"711\" data-end=\"736\"\u003eDriver compatibility:\u003c\/strong\u003e 1.25 mm hand driver\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"760\" data-end=\"763\"\u003e\n\u003ch3 data-start=\"765\" data-end=\"803\"\u003eKey Features \u0026amp; Clinical Benefits\u003c\/h3\u003e\n\u003cul data-start=\"804\" data-end=\"1107\"\u003e\n\u003cli data-start=\"804\" data-end=\"850\"\u003e\n\u003cp data-start=\"806\" data-end=\"850\"\u003eSecure screw connection for stable seating\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"851\" data-end=\"911\"\u003e\n\u003cp data-start=\"853\" data-end=\"911\"\u003eDesigned for predictable closed tray impression workflow\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"912\" data-end=\"984\"\u003e\n\u003cp data-start=\"914\" data-end=\"984\"\u003eStainless steel construction for durability and dimensional accuracy\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"985\" data-end=\"1045\"\u003e\n\u003cp data-start=\"987\" data-end=\"1045\"\u003eManual torque protocol minimizes risk of over-tightening\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1046\" data-end=\"1107\"\u003e\n\u003cp data-start=\"1048\" data-end=\"1107\"\u003eAccurate transfer of implant position to laboratory model\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1109\" data-end=\"1112\"\u003e\n\u003ch3 data-start=\"1114\" data-end=\"1137\"\u003eClinical Protocol\u003c\/h3\u003e\n\u003col data-start=\"1138\" data-end=\"1399\"\u003e\n\u003cli data-start=\"1138\" data-end=\"1178\"\u003e\n\u003cp data-start=\"1141\" data-end=\"1178\"\u003eSeat the transfer onto the implant.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1179\" data-end=\"1240\"\u003e\n\u003cp data-start=\"1182\" data-end=\"1240\"\u003eTighten manually (5–10 Ncm) using a 1.25 mm hand driver.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1241\" data-end=\"1278\"\u003e\n\u003cp data-start=\"1244\" data-end=\"1278\"\u003eTake the closed tray impression.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1279\" data-end=\"1399\"\u003e\n\u003cp data-start=\"1282\" data-end=\"1399\"\u003eAfter impression removal, detach the transfer and reposition it into the impression prior to laboratory processing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003chr data-start=\"1401\" data-end=\"1404\"\u003e\n\u003ch3 data-start=\"1406\" data-end=\"1415\"\u003eFAQ\u003c\/h3\u003e\n\u003cp data-start=\"1417\" data-end=\"1515\"\u003e\u003cstrong data-start=\"1417\" data-end=\"1468\"\u003e1. Which impression technique is this used for?\u003c\/strong\u003e\u003cbr data-start=\"1468\" data-end=\"1471\"\u003eClosed tray (indirect) impression technique.\u003c\/p\u003e\n\u003cp data-start=\"1517\" data-end=\"1590\"\u003e\u003cstrong data-start=\"1517\" data-end=\"1554\"\u003e2. What torque should be applied?\u003c\/strong\u003e\u003cbr data-start=\"1554\" data-end=\"1557\"\u003eManual tightening only, 5–10 Ncm.\u003c\/p\u003e\n\u003cp data-start=\"1592\" data-end=\"1647\"\u003e\u003cstrong data-start=\"1592\" data-end=\"1624\"\u003e3. Which driver is required?\u003c\/strong\u003e\u003cbr data-start=\"1624\" data-end=\"1627\"\u003e1.25 mm hand driver.\u003c\/p\u003e\n\u003cp data-start=\"1649\" data-end=\"1713\"\u003e\u003cstrong data-start=\"1649\" data-end=\"1694\"\u003e4. What material is the transfer made of?\u003c\/strong\u003e\u003cbr data-start=\"1694\" data-end=\"1697\"\u003eStainless steel.\u003c\/p\u003e","brand":"Alfa Gate","offers":[{"title":"SP PLATFORM \/ TRANSFERS","offer_id":43754198499580,"sku":"AGM-305","price":16.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0657\/2788\/9660\/products\/AGM-305.png?v=1663162867"},{"product_id":"transfer-with-plastic-sleeve-close-tray","title":"Transfer with Plastic Sleeve (Close Tray)","description":"\u003cp data-start=\"72\" data-end=\"240\"\u003eThe \u003cstrong data-start=\"76\" data-end=\"132\"\u003eAlfa Gate Transfer with Plastic Sleeve (Closed Tray)\u003c\/strong\u003e is designed for accurate implant position transfer using the indirect (closed tray) impression technique.\u003c\/p\u003e\n\u003cp data-start=\"242\" data-end=\"471\"\u003eManufactured from \u003cstrong data-start=\"260\" data-end=\"279\"\u003estainless steel\u003c\/strong\u003e and supplied with a plastic sleeve, it ensures stable seating, secure retention within the impression material, and precise repositioning onto the implant analog during laboratory procedures.\u003c\/p\u003e\n\u003chr data-start=\"473\" data-end=\"476\"\u003e\n\u003ch3 data-start=\"478\" data-end=\"508\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul data-start=\"509\" data-end=\"756\"\u003e\n\u003cli data-start=\"509\" data-end=\"550\"\u003e\n\u003cp data-start=\"511\" data-end=\"550\"\u003e\u003cstrong data-start=\"511\" data-end=\"525\"\u003eTechnique:\u003c\/strong\u003e Closed tray (indirect)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"509\" data-end=\"550\"\u003e\n\u003cstrong\u003ePlatform:\u003c\/strong\u003e SP Platform \u003c\/li\u003e\n\u003cli data-start=\"551\" data-end=\"573\"\u003e\n\u003cp data-start=\"553\" data-end=\"573\"\u003e\u003cstrong data-start=\"553\" data-end=\"564\"\u003eHeight:\u003c\/strong\u003e 8.5 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"574\" data-end=\"635\"\u003e\n\u003cp data-start=\"576\" data-end=\"635\"\u003e\u003cstrong data-start=\"576\" data-end=\"589\"\u003eMaterial:\u003c\/strong\u003e Stainless Steel (transfer) + Plastic sleeve\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"636\" data-end=\"706\"\u003e\n\u003cp data-start=\"638\" data-end=\"706\"\u003e\u003cstrong data-start=\"638\" data-end=\"661\"\u003eRecommended torque:\u003c\/strong\u003e 5–10 Ncm (manual, light finger-tight only)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"707\" data-end=\"756\"\u003e\n\u003cp data-start=\"709\" data-end=\"756\"\u003e\u003cstrong data-start=\"709\" data-end=\"734\"\u003eDriver compatibility:\u003c\/strong\u003e 1.25 mm hand driver\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"758\" data-end=\"761\"\u003e\n\u003ch3 data-start=\"763\" data-end=\"801\"\u003eKey Features \u0026amp; Clinical Benefits\u003c\/h3\u003e\n\u003cul data-start=\"802\" data-end=\"1103\"\u003e\n\u003cli data-start=\"802\" data-end=\"866\"\u003e\n\u003cp data-start=\"804\" data-end=\"866\"\u003eDesigned for predictable \u003cstrong data-start=\"829\" data-end=\"864\"\u003eclosed tray impression workflow\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"867\" data-end=\"931\"\u003e\n\u003cp data-start=\"869\" data-end=\"931\"\u003eStainless steel body for durability and dimensional accuracy\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"932\" data-end=\"989\"\u003e\n\u003cp data-start=\"934\" data-end=\"989\"\u003ePlastic sleeve enhances impression material retention\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"990\" data-end=\"1041\"\u003e\n\u003cp data-start=\"992\" data-end=\"1041\"\u003eManual torque protocol prevents over-tightening\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1042\" data-end=\"1103\"\u003e\n\u003cp data-start=\"1044\" data-end=\"1103\"\u003eReliable transfer of implant 3D position to working model\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1105\" data-end=\"1108\"\u003e\n\u003ch3 data-start=\"1110\" data-end=\"1133\"\u003eClinical Protocol\u003c\/h3\u003e\n\u003col data-start=\"1134\" data-end=\"1382\"\u003e\n\u003cli data-start=\"1134\" data-end=\"1174\"\u003e\n\u003cp data-start=\"1137\" data-end=\"1174\"\u003eSeat the transfer onto the implant.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1175\" data-end=\"1236\"\u003e\n\u003cp data-start=\"1178\" data-end=\"1236\"\u003eTighten manually (5–10 Ncm) using a 1.25 mm hand driver.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1237\" data-end=\"1274\"\u003e\n\u003cp data-start=\"1240\" data-end=\"1274\"\u003eTake the closed tray impression.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1275\" data-end=\"1382\"\u003e\n\u003cp data-start=\"1278\" data-end=\"1382\"\u003eAfter impression removal, detach transfer and reposition into impression before laboratory processing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003chr data-start=\"1384\" data-end=\"1387\"\u003e\n\u003ch3 data-start=\"1389\" data-end=\"1398\"\u003eFAQ\u003c\/h3\u003e\n\u003cp data-start=\"1400\" data-end=\"1487\"\u003e\u003cstrong data-start=\"1400\" data-end=\"1440\"\u003e1. Which technique is this used for?\u003c\/strong\u003e\u003cbr data-start=\"1440\" data-end=\"1443\"\u003eClosed tray (indirect) impression technique.\u003c\/p\u003e\n\u003cp data-start=\"1489\" data-end=\"1562\"\u003e\u003cstrong data-start=\"1489\" data-end=\"1526\"\u003e2. What torque should be applied?\u003c\/strong\u003e\u003cbr data-start=\"1526\" data-end=\"1529\"\u003eManual tightening only, 5–10 Ncm.\u003c\/p\u003e\n\u003cp data-start=\"1564\" data-end=\"1619\"\u003e\u003cstrong data-start=\"1564\" data-end=\"1596\"\u003e3. Which driver is required?\u003c\/strong\u003e\u003cbr data-start=\"1596\" data-end=\"1599\"\u003e1.25 mm hand driver.\u003c\/p\u003e\n\u003cp data-start=\"1621\" data-end=\"1717\"\u003e\u003cstrong data-start=\"1621\" data-end=\"1666\"\u003e4. What material is the transfer made of?\u003c\/strong\u003e\u003cbr data-start=\"1666\" data-end=\"1669\"\u003eStainless steel with a plastic sleeve component.\u003c\/p\u003e","brand":"Alfa Gate","offers":[{"title":"SP PLATFORM \/ TRANSFERS","offer_id":43754186965244,"sku":"AGM-304","price":23.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0657\/2788\/9660\/products\/AGM-304.png?v=1663162955"},{"product_id":"plastic-sleeve-for-transfer-4-pieces","title":"Plastic Sleeve for Transfer 4 Pieces (closed tray)","description":"\u003cp data-start=\"80\" data-end=\"349\"\u003eThe \u003cstrong data-start=\"84\" data-end=\"139\"\u003eAlfa Gate Plastic Sleeve for Transfer (Closed Tray)\u003c\/strong\u003e is designed for use with closed tray impression transfers.\u003cbr data-start=\"198\" data-end=\"201\"\u003eIts retentive geometry ensures secure engagement within the impression material, enabling accurate implant position replication in the master model.\u003c\/p\u003e\n\u003cp data-start=\"351\" data-end=\"460\"\u003eSupplied as a \u003cstrong data-start=\"365\" data-end=\"380\"\u003e4-piece set\u003c\/strong\u003e, it supports efficient clinical workflow during indirect impression procedures.\u003c\/p\u003e\n\u003chr data-start=\"462\" data-end=\"465\"\u003e\n\u003ch3 data-start=\"467\" data-end=\"497\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul data-start=\"498\" data-end=\"755\"\u003e\n\u003cli data-start=\"498\" data-end=\"559\"\u003e\n\u003cp data-start=\"500\" data-end=\"559\"\u003e\u003cstrong data-start=\"500\" data-end=\"517\"\u003eProduct type:\u003c\/strong\u003e Plastic sleeve for closed tray transfer\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"498\" data-end=\"559\"\u003e\n\u003cstrong\u003ePlatform:\u003c\/strong\u003e SP platform \u003c\/li\u003e\n\u003cli data-start=\"560\" data-end=\"586\"\u003e\n\u003cp data-start=\"562\" data-end=\"586\"\u003e\u003cstrong data-start=\"562\" data-end=\"575\"\u003eQuantity:\u003c\/strong\u003e 4 pieces\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"587\" data-end=\"608\"\u003e\n\u003cp data-start=\"589\" data-end=\"608\"\u003e\u003cstrong data-start=\"589\" data-end=\"600\"\u003eHeight:\u003c\/strong\u003e 11 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"609\" data-end=\"634\"\u003e\n\u003cp data-start=\"611\" data-end=\"634\"\u003e\u003cstrong data-start=\"611\" data-end=\"624\"\u003eMaterial:\u003c\/strong\u003e Plastic\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"635\" data-end=\"705\"\u003e\n\u003cp data-start=\"637\" data-end=\"705\"\u003e\u003cstrong data-start=\"637\" data-end=\"660\"\u003eRecommended torque:\u003c\/strong\u003e 5–10 Ncm (manual, light finger-tight only)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"706\" data-end=\"755\"\u003e\n\u003cp data-start=\"708\" data-end=\"755\"\u003e\u003cstrong data-start=\"708\" data-end=\"733\"\u003eDriver compatibility:\u003c\/strong\u003e 1.25 mm hand driver\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"757\" data-end=\"760\"\u003e\n\u003ch3 data-start=\"762\" data-end=\"800\"\u003eKey Features \u0026amp; Clinical Benefits\u003c\/h3\u003e\n\u003cul data-start=\"801\" data-end=\"1131\"\u003e\n\u003cli data-start=\"801\" data-end=\"865\"\u003e\n\u003cp data-start=\"803\" data-end=\"865\"\u003eDesigned for \u003cstrong data-start=\"816\" data-end=\"863\"\u003eclosed tray (indirect) impression technique\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"866\" data-end=\"931\"\u003e\n\u003cp data-start=\"868\" data-end=\"931\"\u003eRetentive macro-design for stable impression material locking\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"932\" data-end=\"996\"\u003e\n\u003cp data-start=\"934\" data-end=\"996\"\u003eLightweight plastic construction for easy intraoral handling\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"997\" data-end=\"1061\"\u003e\n\u003cp data-start=\"999\" data-end=\"1061\"\u003eManual torque protocol (5–10 Ncm) to prevent over-tightening\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1062\" data-end=\"1131\"\u003e\n\u003cp data-start=\"1064\" data-end=\"1131\"\u003eEnsures precise transfer of implant position to laboratory analog\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1133\" data-end=\"1136\"\u003e\n\u003ch3 data-start=\"1138\" data-end=\"1161\"\u003eClinical Protocol\u003c\/h3\u003e\n\u003col data-start=\"1162\" data-end=\"1395\"\u003e\n\u003cli data-start=\"1162\" data-end=\"1213\"\u003e\n\u003cp data-start=\"1165\" data-end=\"1213\"\u003eSeat the transfer and sleeve onto the implant.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1214\" data-end=\"1275\"\u003e\n\u003cp data-start=\"1217\" data-end=\"1275\"\u003eTighten manually (5–10 Ncm) using a 1.25 mm hand driver.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1276\" data-end=\"1316\"\u003e\n\u003cp data-start=\"1279\" data-end=\"1316\"\u003ePerform the closed tray impression.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1317\" data-end=\"1395\"\u003e\n\u003cp data-start=\"1320\" data-end=\"1395\"\u003eRemove impression and reposition components before laboratory processing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003chr data-start=\"1397\" data-end=\"1400\"\u003e\n\u003ch3 data-start=\"1402\" data-end=\"1411\"\u003eFAQ\u003c\/h3\u003e\n\u003cp data-start=\"1413\" data-end=\"1507\"\u003e\u003cstrong data-start=\"1413\" data-end=\"1460\"\u003e1. Which technique is this sleeve used for?\u003c\/strong\u003e\u003cbr data-start=\"1460\" data-end=\"1463\"\u003eClosed tray (indirect) impression technique.\u003c\/p\u003e\n\u003cp data-start=\"1509\" data-end=\"1582\"\u003e\u003cstrong data-start=\"1509\" data-end=\"1546\"\u003e2. What torque should be applied?\u003c\/strong\u003e\u003cbr data-start=\"1546\" data-end=\"1549\"\u003eManual tightening only, 5–10 Ncm.\u003c\/p\u003e\n\u003cp data-start=\"1584\" data-end=\"1639\"\u003e\u003cstrong data-start=\"1584\" data-end=\"1616\"\u003e3. Which driver is required?\u003c\/strong\u003e\u003cbr data-start=\"1616\" data-end=\"1619\"\u003e1.25 mm hand driver.\u003c\/p\u003e\n\u003cp data-start=\"1641\" data-end=\"1710\"\u003e\u003cstrong data-start=\"1641\" data-end=\"1677\"\u003e4. How many pieces are included?\u003c\/strong\u003e\u003cbr data-start=\"1677\" data-end=\"1680\"\u003e4 plastic sleeves per package.\u003c\/p\u003e","brand":"Alfa Gate","offers":[{"title":"SP PLATFORM \/ TRANSFERS","offer_id":43754047373564,"sku":"AGM-304-P","price":14.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0657\/2788\/9660\/products\/AGM-304-P.png?v=1663163043"},{"product_id":"impression-transfer-open-tray","title":"Open Tray Impression Transfer","description":"\u003cp data-start=\"57\" data-end=\"347\"\u003eThe \u003cstrong data-start=\"61\" data-end=\"104\"\u003eAlfa Gate Open Tray Impression Transfer\u003c\/strong\u003e is designed for precise implant-level impressions using the open tray technique.\u003cbr data-start=\"185\" data-end=\"188\"\u003eIts retentive macro-geometry ensures stable integration within the impression material, allowing accurate transfer of implant position to the laboratory model.\u003c\/p\u003e\n\u003chr data-start=\"349\" data-end=\"352\"\u003e\n\u003ch3 data-start=\"354\" data-end=\"384\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul data-start=\"385\" data-end=\"605\"\u003e\n\u003cli data-start=\"385\" data-end=\"436\"\u003e\n\u003cp data-start=\"387\" data-end=\"436\"\u003e\u003cstrong data-start=\"387\" data-end=\"404\"\u003eProduct type:\u003c\/strong\u003e Open tray impression transfer\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"385\" data-end=\"436\"\u003e\n\u003cstrong\u003ePlatform:\u003c\/strong\u003e SP Platform \u003c\/li\u003e\n\u003cli data-start=\"437\" data-end=\"458\"\u003e\n\u003cp data-start=\"439\" data-end=\"458\"\u003e\u003cstrong data-start=\"439\" data-end=\"450\"\u003eHeight:\u003c\/strong\u003e 14 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"459\" data-end=\"484\"\u003e\n\u003cp data-start=\"461\" data-end=\"484\"\u003e\u003cstrong data-start=\"461\" data-end=\"474\"\u003eMaterial:\u003c\/strong\u003e Plastic\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"485\" data-end=\"555\"\u003e\n\u003cp data-start=\"487\" data-end=\"555\"\u003e\u003cstrong data-start=\"487\" data-end=\"510\"\u003eRecommended torque:\u003c\/strong\u003e 5–10 Ncm (manual, light finger-tight only)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"556\" data-end=\"605\"\u003e\n\u003cp data-start=\"558\" data-end=\"605\"\u003e\u003cstrong data-start=\"558\" data-end=\"583\"\u003eDriver compatibility:\u003c\/strong\u003e 1.25 mm hand driver\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"607\" data-end=\"610\"\u003e\n\u003ch3 data-start=\"612\" data-end=\"650\"\u003eKey Features \u0026amp; Clinical Benefits\u003c\/h3\u003e\n\u003cul data-start=\"651\" data-end=\"969\"\u003e\n\u003cli data-start=\"651\" data-end=\"719\"\u003e\n\u003cp data-start=\"653\" data-end=\"719\"\u003eDesigned specifically for the \u003cstrong data-start=\"683\" data-end=\"717\"\u003eopen tray impression technique\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"720\" data-end=\"787\"\u003e\n\u003cp data-start=\"722\" data-end=\"787\"\u003eRetentive body design for secure impression material engagement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"788\" data-end=\"852\"\u003e\n\u003cp data-start=\"790\" data-end=\"852\"\u003eLightweight plastic construction for easy intraoral handling\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"853\" data-end=\"917\"\u003e\n\u003cp data-start=\"855\" data-end=\"917\"\u003eManual tightening protocol (5–10 Ncm) to prevent overloading\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"918\" data-end=\"969\"\u003e\n\u003cp data-start=\"920\" data-end=\"969\"\u003eSupports accurate laboratory analog positioning\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"971\" data-end=\"974\"\u003e\n\u003ch3 data-start=\"976\" data-end=\"999\"\u003eClinical Protocol\u003c\/h3\u003e\n\u003col data-start=\"1000\" data-end=\"1206\"\u003e\n\u003cli data-start=\"1000\" data-end=\"1040\"\u003e\n\u003cp data-start=\"1003\" data-end=\"1040\"\u003eSeat the transfer onto the implant.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1041\" data-end=\"1102\"\u003e\n\u003cp data-start=\"1044\" data-end=\"1102\"\u003eTighten manually (5–10 Ncm) using a 1.25 mm hand driver.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1103\" data-end=\"1137\"\u003e\n\u003cp data-start=\"1106\" data-end=\"1137\"\u003ePerform open tray impression.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1138\" data-end=\"1206\"\u003e\n\u003cp data-start=\"1141\" data-end=\"1206\"\u003eUnscrew through the tray access before removing the impression.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003chr data-start=\"1208\" data-end=\"1211\"\u003e\n\u003ch3 data-start=\"1213\" data-end=\"1222\"\u003eFAQ\u003c\/h3\u003e\n\u003cp data-start=\"1224\" data-end=\"1336\"\u003e\u003cstrong data-start=\"1224\" data-end=\"1289\"\u003e1. Which impression technique is this component intended for?\u003c\/strong\u003e\u003cbr data-start=\"1289\" data-end=\"1292\"\u003eThe open tray (direct) impression technique.\u003c\/p\u003e\n\u003cp data-start=\"1338\" data-end=\"1411\"\u003e\u003cstrong data-start=\"1338\" data-end=\"1375\"\u003e2. What torque should be applied?\u003c\/strong\u003e\u003cbr data-start=\"1375\" data-end=\"1378\"\u003eManual tightening only, 5–10 Ncm.\u003c\/p\u003e\n\u003cp data-start=\"1413\" data-end=\"1468\"\u003e\u003cstrong data-start=\"1413\" data-end=\"1445\"\u003e3. Which driver is required?\u003c\/strong\u003e\u003cbr data-start=\"1445\" data-end=\"1448\"\u003e1.25 mm hand driver.\u003c\/p\u003e\n\u003cp data-start=\"1470\" data-end=\"1559\"\u003e\u003cstrong data-start=\"1470\" data-end=\"1499\"\u003e4. What material is used?\u003c\/strong\u003e\u003cbr data-start=\"1499\" data-end=\"1502\"\u003eHigh-quality plastic optimized for impression procedures.\u003c\/p\u003e","brand":"Alfa Gate","offers":[{"title":"SP PLATFORM \/ TRANSFERS","offer_id":43753985966332,"sku":"AGM-301","price":20.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0657\/2788\/9660\/products\/AGM-301.png?v=1663163236"},{"product_id":"concave-transfer-open-tay","title":"Concave open tray transfer","description":"\u003cp data-start=\"54\" data-end=\"340\"\u003eThe \u003cstrong data-start=\"58\" data-end=\"98\"\u003eAlfa Gate Concave Open Tray Transfer\u003c\/strong\u003e is designed for accurate implant-level impressions using the open tray technique.\u003cbr data-start=\"180\" data-end=\"183\"\u003eIts concave retention geometry enhances mechanical interlocking with impression material, ensuring stable positioning during removal and laboratory transfer.\u003c\/p\u003e\n\u003chr data-start=\"342\" data-end=\"345\"\u003e\n\u003ch3 data-start=\"347\" data-end=\"377\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul data-start=\"378\" data-end=\"650\"\u003e\n\u003cli data-start=\"378\" data-end=\"429\"\u003e\n\u003cp data-start=\"380\" data-end=\"429\"\u003e\u003cstrong data-start=\"380\" data-end=\"397\"\u003eProduct type:\u003c\/strong\u003e Open tray impression transfer\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"430\" data-end=\"481\"\u003e\n\u003cp data-start=\"432\" data-end=\"481\"\u003e\u003cstrong data-start=\"432\" data-end=\"443\"\u003eDesign:\u003c\/strong\u003e Concave body for enhanced retention\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"482\" data-end=\"503\"\u003e\n\u003cp data-start=\"484\" data-end=\"503\"\u003e\u003cstrong data-start=\"484\" data-end=\"495\"\u003eHeight:\u003c\/strong\u003e 14 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"504\" data-end=\"529\"\u003e\n\u003cp data-start=\"506\" data-end=\"529\"\u003e\u003cstrong data-start=\"506\" data-end=\"519\"\u003eMaterial:\u003c\/strong\u003e Plastic\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"530\" data-end=\"600\"\u003e\n\u003cp data-start=\"532\" data-end=\"600\"\u003e\u003cstrong data-start=\"532\" data-end=\"555\"\u003eRecommended torque:\u003c\/strong\u003e 5–10 Ncm (manual, light finger-tight only)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"601\" data-end=\"650\"\u003e\n\u003cp data-start=\"603\" data-end=\"650\"\u003e\u003cstrong data-start=\"603\" data-end=\"628\"\u003eDriver compatibility:\u003c\/strong\u003e 1.25 mm hand driver\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"652\" data-end=\"655\"\u003e\n\u003ch3 data-start=\"657\" data-end=\"695\"\u003eKey Features \u0026amp; Clinical Benefits\u003c\/h3\u003e\n\u003cul data-start=\"696\" data-end=\"998\"\u003e\n\u003cli data-start=\"696\" data-end=\"772\"\u003e\n\u003cp data-start=\"698\" data-end=\"772\"\u003e\u003cstrong data-start=\"698\" data-end=\"732\"\u003eConcave macro-retention design\u003c\/strong\u003e for improved impression material grip\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"773\" data-end=\"814\"\u003e\n\u003cp data-start=\"775\" data-end=\"814\"\u003e\u003cstrong data-start=\"775\" data-end=\"812\"\u003eOptimized for open tray technique\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"815\" data-end=\"873\"\u003e\n\u003cp data-start=\"817\" data-end=\"873\"\u003e\u003cstrong data-start=\"817\" data-end=\"853\"\u003eLightweight plastic construction\u003c\/strong\u003e for easy handling\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"874\" data-end=\"928\"\u003e\n\u003cp data-start=\"876\" data-end=\"928\"\u003e\u003cstrong data-start=\"876\" data-end=\"926\"\u003eDesigned for manual tightening only (5–10 Ncm)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"929\" data-end=\"998\"\u003e\n\u003cp data-start=\"931\" data-end=\"998\"\u003e\u003cstrong data-start=\"931\" data-end=\"998\"\u003eSupports precise implant position transfer to laboratory models\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1000\" data-end=\"1003\"\u003e\n\u003ch3 data-start=\"1005\" data-end=\"1023\"\u003eClinical Use\u003c\/h3\u003e\n\u003col data-start=\"1024\" data-end=\"1227\"\u003e\n\u003cli data-start=\"1024\" data-end=\"1064\"\u003e\n\u003cp data-start=\"1027\" data-end=\"1064\"\u003eSeat the transfer onto the implant.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1065\" data-end=\"1126\"\u003e\n\u003cp data-start=\"1068\" data-end=\"1126\"\u003eTighten manually (5–10 Ncm) using a 1.25 mm hand driver.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1127\" data-end=\"1167\"\u003e\n\u003cp data-start=\"1130\" data-end=\"1167\"\u003eUse open tray impression technique.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1168\" data-end=\"1227\"\u003e\n\u003cp data-start=\"1171\" data-end=\"1227\"\u003eUnscrew through tray access before impression removal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003chr data-start=\"1229\" data-end=\"1232\"\u003e\n\u003ch3 data-start=\"1234\" data-end=\"1243\"\u003eFAQ\u003c\/h3\u003e\n\u003cp data-start=\"1245\" data-end=\"1367\"\u003e\u003cstrong data-start=\"1245\" data-end=\"1293\"\u003e1. What technique is this transfer used for?\u003c\/strong\u003e\u003cbr data-start=\"1293\" data-end=\"1296\"\u003eIt is designed specifically for the \u003cstrong data-start=\"1332\" data-end=\"1366\"\u003eopen tray impression technique\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"1369\" data-end=\"1486\"\u003e\u003cstrong data-start=\"1369\" data-end=\"1400\"\u003e2. Why is the body concave?\u003c\/strong\u003e\u003cbr data-start=\"1400\" data-end=\"1403\"\u003eThe concave geometry increases mechanical retention within the impression material.\u003c\/p\u003e\n\u003cp data-start=\"1488\" data-end=\"1597\"\u003e\u003cstrong data-start=\"1488\" data-end=\"1525\"\u003e3. What torque should be applied?\u003c\/strong\u003e\u003cbr data-start=\"1525\" data-end=\"1528\"\u003eManual tightening only, \u003cstrong data-start=\"1552\" data-end=\"1564\"\u003e5–10 Ncm\u003c\/strong\u003e using a \u003cstrong data-start=\"1573\" data-end=\"1596\"\u003e1.25 mm hand driver\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"1599\" data-end=\"1701\"\u003e\u003cstrong data-start=\"1599\" data-end=\"1636\"\u003e4. What material is it made from?\u003c\/strong\u003e\u003cbr data-start=\"1636\" data-end=\"1639\"\u003eHigh-quality \u003cstrong data-start=\"1652\" data-end=\"1663\"\u003eplastic\u003c\/strong\u003e, optimized for impression procedures.\u003c\/p\u003e","brand":"Alfa Gate","offers":[{"title":"SP PLATFORM \/ TRANSFERS","offer_id":43743946014972,"sku":"AGM-301-C","price":20.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0657\/2788\/9660\/products\/AGM-301-C.png?v=1663163289"},{"product_id":"transfer-for-patro-implant-one-piece","title":"Transfer for Patro Implant (One Piece)","description":"\u003cp\u003e\u003cspan\u003e\u003c\/span\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003eThe \u003c\/span\u003e\u003cstrong data-start=\"71\" data-end=\"123\" style=\"font-size: 0.875rem;\"\u003eAlfa Gate Transfer for Patro Implant (One Piece)\u003c\/strong\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003e is designed for \u003c\/span\u003e\u003cstrong data-start=\"140\" data-end=\"170\" style=\"font-size: 0.875rem;\"\u003eaccurate impression taking\u003c\/strong\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003e with the Patro one-piece implant system.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"67\" data-end=\"353\"\u003eManufactured from \u003cstrong data-start=\"232\" data-end=\"251\"\u003edurable plastic\u003c\/strong\u003e, it allows precise transfer of the implant position from the clinical situation to the working model.\u003c\/p\u003e\n\u003chr data-start=\"355\" data-end=\"358\"\u003e\n\u003ch3 data-start=\"360\" data-end=\"388\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul data-start=\"389\" data-end=\"547\"\u003e\n\u003cli data-start=\"389\" data-end=\"448\"\u003e\n\u003cp data-start=\"391\" data-end=\"448\"\u003e\u003cstrong data-start=\"391\" data-end=\"408\"\u003eProduct type:\u003c\/strong\u003e Transfer coping for one-piece implant\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"449\" data-end=\"499\"\u003e\n\u003cp data-start=\"451\" data-end=\"499\"\u003e\u003cstrong data-start=\"451\" data-end=\"473\"\u003eCompatible system:\u003c\/strong\u003e Patro one-piece implant\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"500\" data-end=\"521\"\u003e\n\u003cp data-start=\"502\" data-end=\"521\"\u003e\u003cstrong data-start=\"502\" data-end=\"513\"\u003eHeight:\u003c\/strong\u003e 11 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"522\" data-end=\"547\"\u003e\n\u003cp data-start=\"524\" data-end=\"547\"\u003e\u003cstrong data-start=\"524\" data-end=\"537\"\u003eMaterial:\u003c\/strong\u003e Plastic\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"549\" data-end=\"552\"\u003e\n\u003ch3 data-start=\"554\" data-end=\"583\"\u003eKey Features and Benefits\u003c\/h3\u003e\n\u003cul data-start=\"584\" data-end=\"827\"\u003e\n\u003cli data-start=\"584\" data-end=\"655\"\u003e\n\u003cp data-start=\"586\" data-end=\"655\"\u003e\u003cstrong data-start=\"586\" data-end=\"624\"\u003eAccurate implant position transfer\u003c\/strong\u003e during impression procedures\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"656\" data-end=\"716\"\u003e\n\u003cp data-start=\"658\" data-end=\"716\"\u003e\u003cstrong data-start=\"658\" data-end=\"714\"\u003eDesigned specifically for the Patro one-piece system\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"717\" data-end=\"775\"\u003e\n\u003cp data-start=\"719\" data-end=\"775\"\u003e\u003cstrong data-start=\"719\" data-end=\"755\"\u003eLightweight plastic construction\u003c\/strong\u003e for easy handling\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"776\" data-end=\"827\"\u003e\n\u003cp data-start=\"778\" data-end=\"827\"\u003e\u003cstrong data-start=\"778\" data-end=\"827\"\u003eSupports precise laboratory model fabrication\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"829\" data-end=\"832\"\u003e\n\u003ch3 data-start=\"834\" data-end=\"841\"\u003eFAQ\u003c\/h3\u003e\n\u003cp data-start=\"843\" data-end=\"1024\"\u003e\u003cstrong data-start=\"843\" data-end=\"887\"\u003e1. What is the purpose of this transfer?\u003c\/strong\u003e\u003cbr data-start=\"887\" data-end=\"890\"\u003eIt is used during the \u003cstrong data-start=\"912\" data-end=\"932\"\u003eimpression stage\u003c\/strong\u003e to accurately transfer the position of the Patro one-piece implant to the laboratory model.\u003c\/p\u003e\n\u003cp data-start=\"1026\" data-end=\"1153\"\u003e\u003cstrong data-start=\"1026\" data-end=\"1076\"\u003e2. Which implant system is it compatible with?\u003c\/strong\u003e\u003cbr data-start=\"1076\" data-end=\"1079\"\u003eIt is designed specifically for the \u003cstrong data-start=\"1115\" data-end=\"1152\"\u003eAlfa Gate Patro one-piece implant\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"1155\" data-end=\"1274\"\u003e\u003cstrong data-start=\"1155\" data-end=\"1192\"\u003e3. What material is it made from?\u003c\/strong\u003e\u003cbr data-start=\"1192\" data-end=\"1195\"\u003eIt is manufactured from \u003cstrong data-start=\"1219\" data-end=\"1238\"\u003edurable plastic\u003c\/strong\u003e for reliable impression procedures.\u003c\/p\u003e\n\u003cp data-start=\"1276\" data-end=\"1354\"\u003e\u003cstrong data-start=\"1276\" data-end=\"1318\"\u003e4. What is the height of the transfer?\u003c\/strong\u003e\u003cbr data-start=\"1318\" data-end=\"1321\"\u003eThe transfer height is \u003cstrong data-start=\"1344\" data-end=\"1353\"\u003e11 mm\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Alfa Gate","offers":[{"title":"ONE-PIECE \/ TRANSFERS","offer_id":43754184835324,"sku":"AGM-306","price":12.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0657\/2788\/9660\/products\/AGM-306.png?v=1663163604"},{"product_id":"copy-of-s-line-transfer-for-open-tray-impression","title":"CLOSE TRAY IMPRESSION SCREW CONNECTION","description":"\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003ciframe title=\"Implant impression taking- open tray | Alfa Gate\" src=\"https:\/\/www.youtube.com\/embed\/ZjrKAG0hzWU\" height=\"720\" width=\"1280\"\u003e\u003c\/iframe\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp data-start=\"356\" data-end=\"689\"\u003eThe \u003cstrong data-start=\"360\" data-end=\"402\"\u003eClose Tray Impression Screw Connection\u003c\/strong\u003e is designed for accurate and efficient \u003cstrong data-start=\"442\" data-end=\"479\"\u003eclosed-tray impression procedures\u003c\/strong\u003e on \u003cstrong data-start=\"483\" data-end=\"509\"\u003e3.0 mm S-Line implants\u003c\/strong\u003e.\u003cbr data-start=\"510\" data-end=\"513\"\u003eIt ensures stable positioning during impression taking while allowing easy removal after tray separation, supporting predictable transfer of implant position to the laboratory.\u003c\/p\u003e\n\u003chr data-start=\"691\" data-end=\"694\"\u003e\n\u003ch2 data-start=\"696\" data-end=\"726\"\u003e Technical Specifications\u003c\/h2\u003e\n\u003cul data-start=\"728\" data-end=\"1119\"\u003e\n\u003cli data-start=\"728\" data-end=\"772\"\u003e\n\u003cp data-start=\"730\" data-end=\"772\"\u003e\u003cstrong data-start=\"730\" data-end=\"743\"\u003ePlatform:\u003c\/strong\u003e S-Line (3.0 mm internal hex)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"773\" data-end=\"837\"\u003e\n\u003cp data-start=\"775\" data-end=\"837\"\u003e\u003cstrong data-start=\"775\" data-end=\"795\"\u003eConnection Type:\u003c\/strong\u003e Internal hex (S-Line straight connection)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"838\" data-end=\"869\"\u003e\n\u003cp data-start=\"840\" data-end=\"869\"\u003e\u003cstrong data-start=\"840\" data-end=\"853\"\u003eMaterial:\u003c\/strong\u003e Stainless steel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"870\" data-end=\"929\"\u003e\n\u003cp data-start=\"872\" data-end=\"929\"\u003e\u003cstrong data-start=\"872\" data-end=\"897\"\u003eImpression Technique:\u003c\/strong\u003e Close tray (indirect technique)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"930\" data-end=\"1016\"\u003e\n\u003cp data-start=\"932\" data-end=\"1016\"\u003e\u003cstrong data-start=\"932\" data-end=\"955\"\u003eRecommended Torque:\u003c\/strong\u003e\u003cbr data-start=\"955\" data-end=\"958\"\u003eManual tightening only — light finger-tight \u003cstrong data-start=\"1004\" data-end=\"1016\"\u003e5–10 Ncm\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1017\" data-end=\"1063\"\u003e\n\u003cp data-start=\"1019\" data-end=\"1063\"\u003e\u003cstrong data-start=\"1019\" data-end=\"1044\"\u003eDriver Compatibility:\u003c\/strong\u003e Hex driver 1.25 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1064\" data-end=\"1097\"\u003e\n\u003cp data-start=\"1066\" data-end=\"1097\"\u003e\u003cstrong data-start=\"1066\" data-end=\"1084\"\u003eSterilization:\u003c\/strong\u003e Autoclavable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1098\" data-end=\"1119\"\u003e\n\u003cp data-start=\"1100\" data-end=\"1119\"\u003e\u003cstrong data-start=\"1100\" data-end=\"1108\"\u003eSKU:\u003c\/strong\u003e AGM-303-SL\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1121\" data-end=\"1124\"\u003e\n\u003ch2 data-start=\"1126\" data-end=\"1164\"\u003eKey Features \u0026amp; Clinical Benefits\u003c\/h2\u003e\n\u003cul data-start=\"1166\" data-end=\"1791\"\u003e\n\u003cli data-start=\"1166\" data-end=\"1289\"\u003e\n\u003cp data-start=\"1168\" data-end=\"1289\"\u003e\u003cstrong data-start=\"1168\" data-end=\"1212\"\u003eAccurate Closed-Tray Impression Transfer\u003c\/strong\u003e\u003cbr data-start=\"1212\" data-end=\"1215\"\u003eDesigned to maintain precise implant position during impression removal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1291\" data-end=\"1448\"\u003e\n\u003cp data-start=\"1293\" data-end=\"1448\"\u003e\u003cstrong data-start=\"1293\" data-end=\"1341\"\u003eOptimized for S-Line Internal Hex Connection\u003c\/strong\u003e\u003cbr data-start=\"1341\" data-end=\"1344\"\u003eFully compatible with \u003cstrong data-start=\"1368\" data-end=\"1407\"\u003eS-Line 2.0 mm internal hex geometry\u003c\/strong\u003e, ensuring correct seating and stability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1450\" data-end=\"1561\"\u003e\n\u003cp data-start=\"1452\" data-end=\"1561\"\u003e\u003cstrong data-start=\"1452\" data-end=\"1484\"\u003eControlled Manual Tightening\u003c\/strong\u003e\u003cbr data-start=\"1484\" data-end=\"1487\"\u003eLight finger-tight protocol prevents thread damage and over-compression.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1563\" data-end=\"1680\"\u003e\n\u003cp data-start=\"1565\" data-end=\"1680\"\u003e\u003cstrong data-start=\"1565\" data-end=\"1605\"\u003eDurable Stainless Steel Construction\u003c\/strong\u003e\u003cbr data-start=\"1605\" data-end=\"1608\"\u003eProvides dimensional stability and repeated sterilization reliability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1682\" data-end=\"1791\"\u003e\n\u003cp data-start=\"1684\" data-end=\"1791\"\u003e\u003cstrong data-start=\"1684\" data-end=\"1711\"\u003eEasy Handling \u0026amp; Removal\u003c\/strong\u003e\u003cbr data-start=\"1711\" data-end=\"1714\"\u003eFacilitates smooth impression procedures with minimal chairside complexity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1793\" data-end=\"1796\"\u003e\n\u003ch2 data-start=\"1798\" data-end=\"1836\"\u003eFrequently Asked Questions (FAQ)\u003c\/h2\u003e\n\u003cp data-start=\"1838\" data-end=\"2026\"\u003e\u003cstrong data-start=\"1838\" data-end=\"1901\"\u003eQ: Which implants is this impression screw compatible with?\u003c\/strong\u003e\u003cbr data-start=\"1901\" data-end=\"1904\"\u003eA: It is compatible exclusively with \u003cstrong data-start=\"1941\" data-end=\"1988\"\u003eAlfa Gate S-Line implants (3.0 mm platform)\u003c\/strong\u003e featuring an internal hex connection.\u003c\/p\u003e\n\u003cp data-start=\"2028\" data-end=\"2175\"\u003e\u003cstrong data-start=\"2028\" data-end=\"2089\"\u003eQ: Is this used for open-tray or closed-tray impressions?\u003c\/strong\u003e\u003cbr data-start=\"2089\" data-end=\"2092\"\u003eA: This component is designed for \u003cstrong data-start=\"2126\" data-end=\"2174\"\u003eclosed-tray (indirect) impression techniques\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"2177\" data-end=\"2305\"\u003e\u003cstrong data-start=\"2177\" data-end=\"2229\"\u003eQ: Can I torque this screw with a torque wrench?\u003c\/strong\u003e\u003cbr data-start=\"2229\" data-end=\"2232\"\u003eA: No. Only \u003cstrong data-start=\"2244\" data-end=\"2289\"\u003emanual finger-tight tightening (5–10 Ncm)\u003c\/strong\u003e is recommended.\u003c\/p\u003e\n\u003cp data-start=\"2307\" data-end=\"2378\"\u003e\u003cstrong data-start=\"2307\" data-end=\"2342\"\u003eQ: Which driver should be used?\u003c\/strong\u003e\u003cbr data-start=\"2342\" data-end=\"2345\"\u003eA: A \u003cstrong data-start=\"2350\" data-end=\"2377\"\u003e1.25 mm hex hand driver\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"2380\" data-end=\"2487\"\u003e\u003cstrong data-start=\"2380\" data-end=\"2416\"\u003eQ: Can this component be reused?\u003c\/strong\u003e\u003cbr data-start=\"2416\" data-end=\"2419\"\u003eA: Yes. It is made of stainless steel and is \u003cstrong data-start=\"2464\" data-end=\"2486\"\u003efully autoclavable\u003c\/strong\u003e.\u003c\/p\u003e","brand":"Alfa Gate","offers":[{"title":"11mm \/ S-LINE PLATFORM \/ TRANSFERS","offer_id":44693805465852,"sku":"AGM-303-SL","price":18.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0657\/2788\/9660\/files\/AGM-303-SLforclosetrayimpressionscrewconnection_e82c9bdc-964f-4c5f-8948-ff3ca96de8d8.png?v=1697715670"},{"product_id":"transfer-with-screw-connection-closed-tray","title":"Transfer with Screw Connection (Closed Tray)","description":"\u003cp data-path-to-node=\"6\"\u003eThe Alfa Gate \u003cb data-path-to-node=\"6\" data-index-in-node=\"32\"\u003eTransfer with Screw Connection (SKU: AGM-305)\u003c\/b\u003e is a high-precision component designed for \u003cb data-path-to-node=\"6\" data-index-in-node=\"121\"\u003eClosed Tray\u003c\/b\u003e impression techniques. This transfer is compatible with Alfa Gate's standard internal hex platform (2.42mm hex). Fabricated from durable, medical-grade \u003cb data-path-to-node=\"6\" data-index-in-node=\"285\"\u003eStainless Steel\u003c\/b\u003e, it ensures the exact clinical position of the implant is captured and transferred to the laboratory analog with zero margin for error.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"7\"\u003e\u003cb data-path-to-node=\"7\" data-index-in-node=\"0\"\u003eTechnical Specifications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-path-to-node=\"8\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,0,0\"\u003e\u003cb data-path-to-node=\"8,0,0\" data-index-in-node=\"0\"\u003ePlatform Compatibility:\u003c\/b\u003e Standard Platform (SP) – 2.42mm Internal Hex.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,1,0\"\u003e\u003cb data-path-to-node=\"8,1,0\" data-index-in-node=\"0\"\u003eImpression Technique:\u003c\/b\u003e Closed Tray (Screw-retained).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,2,0\"\u003e\u003cb data-path-to-node=\"8,2,0\" data-index-in-node=\"0\"\u003eHeight:\u003c\/b\u003e 10 mm.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,3,0\"\u003e\u003cb data-path-to-node=\"8,3,0\" data-index-in-node=\"0\"\u003eMaterial:\u003c\/b\u003e Medical-grade Stainless Steel.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,4,0\"\u003e\u003cb data-path-to-node=\"8,4,0\" data-index-in-node=\"0\"\u003eDriver Requirement:\u003c\/b\u003e 1.25 mm Hex Driver.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,5,0\"\u003e\u003cb data-path-to-node=\"8,5,0\" data-index-in-node=\"0\"\u003eRecommended Torque:\u003c\/b\u003e Manual only – Light finger tight (\u003cb data-path-to-node=\"8,5,0\" data-index-in-node=\"54\"\u003e5–10 Ncm\u003c\/b\u003e).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,6,0\"\u003e\u003cb data-path-to-node=\"8,6,0\" data-index-in-node=\"0\"\u003eSKU:\u003c\/b\u003e AGM-305.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"9\"\u003e\u003cb data-path-to-node=\"9\" data-index-in-node=\"0\"\u003eKey Features \u0026amp; Benefits:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-path-to-node=\"10\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,0,0\"\u003e\u003cb data-path-to-node=\"10,0,0\" data-index-in-node=\"0\"\u003eClassic Precision:\u003c\/b\u003e Perfectly matched to the standard 2.42mm internal hex to prevent rotational inaccuracies during the impression phase.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,1,0\"\u003e\u003cb data-path-to-node=\"10,1,0\" data-index-in-node=\"0\"\u003eExtended Height:\u003c\/b\u003e The 10mm profile provides clear visibility and easy handling, making it ideal for standard gingival depths.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,2,0\"\u003e\u003cb data-path-to-node=\"10,2,0\" data-index-in-node=\"0\"\u003eSecure Engagement:\u003c\/b\u003e Features a deep internal hex and high-quality screw thread to ensure the transfer remains stable within the impression material.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,3,0\"\u003e\u003cb data-path-to-node=\"10,3,0\" data-index-in-node=\"0\"\u003eReliable Durability:\u003c\/b\u003e Stainless steel construction ensures the component maintains its dimensional integrity over repeated clinical and laboratory uses.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"11\"\u003e\n\u003ch3 data-path-to-node=\"12\"\u003e\u003cb data-path-to-node=\"12\" data-index-in-node=\"0\"\u003e3. Frequently Asked Questions (FAQ)\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-path-to-node=\"13\"\u003e\u003cb data-path-to-node=\"13\" data-index-in-node=\"0\"\u003e1. What is the recommended torque for this transfer?\u003c\/b\u003e This component should be tightened \u003cb data-path-to-node=\"13\" data-index-in-node=\"88\"\u003emanually only\u003c\/b\u003e using a 1.25mm hand driver to a light finger-tightness of \u003cb data-path-to-node=\"13\" data-index-in-node=\"160\"\u003e5–10 Ncm\u003c\/b\u003e. Do not use a mechanical torque wrench.\u003c\/p\u003e\n\u003cp data-path-to-node=\"14\"\u003e\u003cb data-path-to-node=\"14\" data-index-in-node=\"0\"\u003e2. Is this compatible with the RC (Conical) platform?\u003c\/b\u003e No. This transfer is designed for the \u003cb data-path-to-node=\"14\" data-index-in-node=\"92\"\u003eStandard 2.42mm Internal Hex\u003c\/b\u003e platform (SP). For conical connections, please use the \u003cb data-path-to-node=\"14\" data-index-in-node=\"176\"\u003eRC Transfer\u003c\/b\u003e series.\u003c\/p\u003e\n\u003cp data-path-to-node=\"15\"\u003e\u003cb data-path-to-node=\"15\" data-index-in-node=\"0\"\u003e3. Which driver do I need?\u003c\/b\u003e A standard \u003cb data-path-to-node=\"15\" data-index-in-node=\"38\"\u003e1.25mm hex driver\u003c\/b\u003e is required to seat the internal screw.\u003c\/p\u003e","brand":"Alfa Gate","offers":[{"title":"SP PLATFORM \/ TRANSFERS","offer_id":45012725891324,"sku":"AGM-305-A","price":16.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0657\/2788\/9660\/files\/products_AGM-305-A.png?v=1707118194"},{"product_id":"implant-transfer-rc","title":"Implant transfer RC - OPEN-TRAY","description":"\u003cp\u003e\u003cspan data-path-to-node=\"10,2\"\u003e\u003cspan class=\"citation-166\"\u003eThe \u003cstrong\u003eAlfa Gate Open-Tray Transfer RC \u003c\/strong\u003eis a specialized impression component engineered for clinicians who require the highest level of accuracy in implant positioning\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-path-to-node=\"10,3\"\u003e\u003cspan class=\"citation-166 citation-end-166\"\u003e\u003csup data-turn-source-index=\"2\" class=\"superscript\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003csup data-turn-source-index=\"2\" class=\"superscript\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003csup data-turn-source-index=\"2\" class=\"superscript\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003csup data-turn-source-index=\"2\" class=\"superscript\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-path-to-node=\"10,4\"\u003e. Fabricated from high-grade \u003cb data-index-in-node=\"29\" data-path-to-node=\"10,4\"\u003eTitanium\u003c\/b\u003e, this transfer is designed for the \u003cb data-index-in-node=\"73\" data-path-to-node=\"10,4\"\u003eRegular Conical (RC)\u003c\/b\u003e platform, ensuring a rigid and stable connection during the impression-taking process. \u003c\/span\u003e\u003cspan data-path-to-node=\"10,5\"\u003e\u003cspan class=\"citation-165\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-path-to-node=\"10,6\"\u003e\u003cspan class=\"citation-165\"\u003eIts open-tray design allows the clinician to unscrew the transfer directly through the impression tray, minimizing the risk of distortion.\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-path-to-node=\"10,7\"\u003e\u003cspan class=\"citation-165 citation-end-165\"\u003e\u003csup data-turn-source-index=\"3\" class=\"superscript\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003csup data-turn-source-index=\"3\" class=\"superscript\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-path-to-node=\"10,8\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan data-path-to-node=\"10,6\"\u003e\u003cspan class=\"citation-165\"\u003eTechnical Specifications:\u003c\/span\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan data-path-to-node=\"10,6\"\u003e\u003cspan class=\"citation-165\"\u003e\u003cspan data-path-to-node=\"12,0,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"12,0,1,0\"\u003e\u003cspan class=\"citation-164\"\u003ePlatform Compatibility:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-164\"\u003e RC – Regular Conical.\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-path-to-node=\"12,0,1,1\"\u003e\u003cspan class=\"citation-164 citation-end-164\"\u003e\u003csup data-turn-source-index=\"4\" class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan data-path-to-node=\"10,6\"\u003e\u003cspan class=\"citation-165\"\u003e\u003cspan data-path-to-node=\"12,0,1,0\"\u003e\u003cspan class=\"citation-164\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"12,1,0\"\u003eImpression Technique:\u003c\/b\u003e Open-Tray (Pick-up technique).\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan data-path-to-node=\"10,6\"\u003e\u003cspan class=\"citation-165\"\u003e\u003cspan data-path-to-node=\"12,0,1,0\"\u003e\u003cspan class=\"citation-164\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"12,2,1,0\"\u003e\u003cspan class=\"citation-163\"\u003eMaterial:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-163\"\u003e Premium Titanium.\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan data-path-to-node=\"10,6\"\u003e\u003cspan class=\"citation-165\"\u003e\u003cspan data-path-to-node=\"12,0,1,0\"\u003e\u003cspan class=\"citation-164\"\u003e\u003cspan class=\"citation-163\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"12,3,1,0\"\u003e\u003cspan class=\"citation-162\"\u003eDriver Compatibility:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-162\"\u003e 1.25 mm Hex Driver.\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan data-path-to-node=\"10,6\"\u003e\u003cspan class=\"citation-165\"\u003e\u003cspan data-path-to-node=\"12,0,1,0\"\u003e\u003cspan class=\"citation-164\"\u003e\u003cspan class=\"citation-163\"\u003e\u003cspan class=\"citation-162\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"12,4,1,0\"\u003e\u003cspan class=\"citation-161\"\u003eRecommended Torque:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-161\"\u003e Manual only – Light finger tight (\u003c\/span\u003e\u003cb data-index-in-node=\"54\" data-path-to-node=\"12,4,1,0\"\u003e\u003cspan class=\"citation-161\"\u003e5–10 Ncm\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-161\"\u003e).\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan data-path-to-node=\"10,6\"\u003e\u003cspan class=\"citation-165\"\u003e\u003cspan data-path-to-node=\"12,0,1,0\"\u003e\u003cspan class=\"citation-164\"\u003e\u003cspan class=\"citation-163\"\u003e\u003cspan class=\"citation-162\"\u003e\u003cspan class=\"citation-161\"\u003e\u003cspan data-path-to-node=\"12,5,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"12,5,1,0\"\u003e\u003cspan class=\"citation-160\"\u003eConnection Type:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-160\"\u003e 11° Conical Sealing (Morse Taper).\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-path-to-node=\"12,5,1,1\"\u003e\u003cspan class=\"citation-160 citation-end-160\"\u003e\u003csup data-turn-source-index=\"8\" class=\"superscript\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003csup data-turn-source-index=\"8\" class=\"superscript\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-path-to-node=\"12,5,1,2\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan data-path-to-node=\"10,6\"\u003e\u003cspan class=\"citation-165\"\u003e\u003cspan data-path-to-node=\"12,0,1,0\"\u003e\u003cspan class=\"citation-164\"\u003e\u003cspan class=\"citation-163\"\u003e\u003cspan class=\"citation-162\"\u003e\u003cspan class=\"citation-161\"\u003e\u003cspan data-path-to-node=\"12,5,1,0\"\u003e\u003cspan class=\"citation-160\"\u003eKey Features \u0026amp; Benefits:\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan data-path-to-node=\"10,6\"\u003e\u003cspan class=\"citation-165\"\u003e\u003cspan data-path-to-node=\"12,0,1,0\"\u003e\u003cspan class=\"citation-164\"\u003e\u003cspan class=\"citation-163\"\u003e\u003cspan class=\"citation-162\"\u003e\u003cspan class=\"citation-161\"\u003e\u003cspan data-path-to-node=\"12,5,1,0\"\u003e\u003cspan class=\"citation-160\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"14,0,1,0\"\u003e\u003cspan class=\"citation-159\"\u003eTitanium Durability:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-159\"\u003e Unlike stainless steel alternatives, the Titanium construction offers superior longevity and ensures the precise internal hex and conical interface remain intact over repeated uses.\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan data-path-to-node=\"10,6\"\u003e\u003cspan class=\"citation-165\"\u003e\u003cspan data-path-to-node=\"12,0,1,0\"\u003e\u003cspan class=\"citation-164\"\u003e\u003cspan class=\"citation-163\"\u003e\u003cspan class=\"citation-162\"\u003e\u003cspan class=\"citation-161\"\u003e\u003cspan data-path-to-node=\"12,5,1,0\"\u003e\u003cspan class=\"citation-160\"\u003e\u003cspan class=\"citation-159\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"14,1,0\"\u003ePick-up Precision:\u003c\/b\u003e The open-tray architecture ensures the transfer remains embedded in the impression material, providing a direct and error-free representation of the implant’s clinical position.\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan data-path-to-node=\"10,6\"\u003e\u003cspan class=\"citation-165\"\u003e\u003cspan data-path-to-node=\"12,0,1,0\"\u003e\u003cspan class=\"citation-164\"\u003e\u003cspan class=\"citation-163\"\u003e\u003cspan class=\"citation-162\"\u003e\u003cspan class=\"citation-161\"\u003e\u003cspan data-path-to-node=\"12,5,1,0\"\u003e\u003cspan class=\"citation-160\"\u003e\u003cspan class=\"citation-159\"\u003e\u003cspan data-path-to-node=\"14,2,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"14,2,1,0\"\u003e\u003cspan class=\"citation-158\"\u003eSecure Sealing:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-158\"\u003e Specifically matched to the Alfa Gate RC 11° conical connection to provide a stable, non-rotational fit during the impression phase.\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-path-to-node=\"14,2,1,1\"\u003e\u003cspan class=\"citation-158 citation-end-158\"\u003e\u003csup data-turn-source-index=\"10\" class=\"superscript\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003csup data-turn-source-index=\"10\" class=\"superscript\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-path-to-node=\"14,2,1,2\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan data-path-to-node=\"10,6\"\u003e\u003cspan class=\"citation-165\"\u003e\u003cspan data-path-to-node=\"12,0,1,0\"\u003e\u003cspan class=\"citation-164\"\u003e\u003cspan class=\"citation-163\"\u003e\u003cspan class=\"citation-162\"\u003e\u003cspan class=\"citation-161\"\u003e\u003cspan data-path-to-node=\"12,5,1,0\"\u003e\u003cspan class=\"citation-160\"\u003e\u003cspan class=\"citation-159\"\u003e\u003cspan data-path-to-node=\"14,2,1,0\"\u003e\u003cspan class=\"citation-158\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"14,3,1,0\"\u003e\u003cspan class=\"citation-157\"\u003eEasy Handling:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-157\"\u003e Featuring a textured grip for easy manual insertion before final tightening with a 1.25mm hex driver.\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"16\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"16\"\u003e4. Frequently Asked Questions (FAQ)\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-path-to-node=\"17\"\u003e\u003cspan data-path-to-node=\"17,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"17,0\"\u003e1. What is the recommended torque for the Open-Tray RC Transfer?\u003c\/b\u003e \u003c\/span\u003e\u003cspan data-path-to-node=\"17,1\"\u003e\u003cspan class=\"citation-156\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-path-to-node=\"17,2\"\u003e\u003cspan class=\"citation-156\"\u003eTo ensure the component can be easily removed and to protect the internal connection, tighten \u003c\/span\u003e\u003cb data-index-in-node=\"94\" data-path-to-node=\"17,2\"\u003e\u003cspan class=\"citation-156\"\u003emanually only\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-156\"\u003e to a light finger-tightness of \u003c\/span\u003e\u003cb data-index-in-node=\"139\" data-path-to-node=\"17,2\"\u003e\u003cspan class=\"citation-156\"\u003e5–10 Ncm.\u003c\/span\u003e\u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-path-to-node=\"17\"\u003e\u003cspan data-path-to-node=\"17,2\"\u003e\u003cstrong\u003e\u003cspan class=\"citation-156\"\u003e\u003cspan data-path-to-node=\"18,0\"\u003e2. Why choose Titanium over Stainless Steel for transfers?\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cb data-index-in-node=\"139\" data-path-to-node=\"17,2\"\u003e\u003cspan class=\"citation-156\"\u003e\u003cspan data-path-to-node=\"18,0\"\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-156\"\u003e\u003cspan data-path-to-node=\"18,2\"\u003e\u003cspan class=\"citation-155\"\u003eTitanium offers exceptional biocompatibility and a higher resistance to wear at the connection interface, ensuring that the 11° Morse taper remains accurate throughout the life of the component.\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-path-to-node=\"10,6\"\u003e\u003cspan class=\"citation-165\"\u003e\u003cspan data-path-to-node=\"12,0,1,0\"\u003e\u003cspan class=\"citation-164\"\u003e\u003cspan class=\"citation-163\"\u003e\u003cspan class=\"citation-162\"\u003e\u003cspan class=\"citation-161\"\u003e\u003cspan data-path-to-node=\"12,5,1,0\"\u003e\u003cspan class=\"citation-160\"\u003e\u003cspan data-path-to-node=\"19,0\"\u003e\u003cb data-path-to-node=\"19,0\" data-index-in-node=\"0\"\u003e3. Which driver is required for the transfer screw?\u003c\/b\u003e \u003c\/span\u003e\u003cspan data-path-to-node=\"19,1\"\u003e\u003cspan class=\"citation-154\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-path-to-node=\"19,2\"\u003e\u003cspan class=\"citation-154\"\u003eThis component is compatible with a standard \u003c\/span\u003e\u003cb data-path-to-node=\"19,2\" data-index-in-node=\"45\"\u003e\u003cspan class=\"citation-154\"\u003e1.25 mm hex driver.\u003c\/span\u003e\u003c\/b\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Alfa Gate","offers":[{"title":"RC PLATFORM \/ TRANSFERS","offer_id":46422715695356,"sku":"AGM-301-RC","price":20.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0657\/2788\/9660\/files\/AGM-301-RC.png?v=1726466791"},{"product_id":"implant-transfer-closed-tray-rc","title":"Implant transfer (Closed Tray) RC","description":"\u003cp data-path-to-node=\"6\"\u003eThe \u003cstrong\u003eAlfa Gate Implant Transfer\u003c\/strong\u003e (\u003cb data-path-to-node=\"6\" data-index-in-node=\"50\"\u003eSKU: AGM-305-RC\u003c\/b\u003e) is designed for high-accuracy \u003cb data-path-to-node=\"6\" data-index-in-node=\"97\"\u003eClosed Tray\u003c\/b\u003e impressions on the \u003cb data-path-to-node=\"6\" data-index-in-node=\"128\"\u003eRegular Conical (RC)\u003c\/b\u003e platform. This component perfectly mirrors the \u003cb data-path-to-node=\"6\" data-index-in-node=\"196\"\u003e11° Morse taper\u003c\/b\u003e and internal hex of the RC implant, ensuring the clinical position is captured and transferred to the laboratory model with absolute precision.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"7\"\u003e\u003cb data-path-to-node=\"7\" data-index-in-node=\"0\"\u003eTechnical Specifications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-path-to-node=\"8\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,0,0\"\u003e\u003cb data-path-to-node=\"8,0,0\" data-index-in-node=\"0\"\u003ePlatform Compatibility:\u003c\/b\u003e RC – Regular Conical.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,1,0\"\u003e\u003cb data-path-to-node=\"8,1,0\" data-index-in-node=\"0\"\u003eImpression Technique:\u003c\/b\u003e Closed Tray.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,2,0\"\u003e\u003cb data-path-to-node=\"8,2,0\" data-index-in-node=\"0\"\u003eHeight:\u003c\/b\u003e 8 mm.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,3,0\"\u003e\u003cb data-path-to-node=\"8,3,0\" data-index-in-node=\"0\"\u003eMaterial:\u003c\/b\u003e Medical-grade Stainless Steel.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,4,0\"\u003e\u003cb data-path-to-node=\"8,4,0\" data-index-in-node=\"0\"\u003eDriver Requirement:\u003c\/b\u003e 1.25 mm Hex Driver.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,5,0\"\u003e\u003cb data-path-to-node=\"8,5,0\" data-index-in-node=\"0\"\u003eRecommended Torque:\u003c\/b\u003e Manual only (Light finger tight: 5–10 Ncm).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,6,0\"\u003e\u003cb data-path-to-node=\"8,6,0\" data-index-in-node=\"0\"\u003eSKU:\u003c\/b\u003e AGM-305-RC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"9\"\u003e\u003cb data-path-to-node=\"9\" data-index-in-node=\"0\"\u003eKey Features \u0026amp; Benefits:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-path-to-node=\"10\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,0,0\"\u003e\u003cb data-path-to-node=\"10,0,0\" data-index-in-node=\"0\"\u003ePrecision Fit:\u003c\/b\u003e Engineered to integrate seamlessly with the RC platform's conical connection, preventing rotational errors during the impression process.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,1,0\"\u003e\u003cb data-path-to-node=\"10,1,0\" data-index-in-node=\"0\"\u003eDurable Construction:\u003c\/b\u003e Made from high-strength stainless steel to ensure longevity and consistent performance over multiple clinical uses.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,2,0\"\u003e\u003cb data-path-to-node=\"10,2,0\" data-index-in-node=\"0\"\u003eStreamlined Workflow:\u003c\/b\u003e The 8mm height is optimized for posterior and anterior cases where vertical space may be limited, but accuracy is paramount.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,3,0\"\u003e\u003cb data-path-to-node=\"10,3,0\" data-index-in-node=\"0\"\u003eSecure Transfer:\u003c\/b\u003e Features distinct retention grooves to ensure the transfer stays securely positioned within the impression material upon removal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"11\"\u003e\n\u003ch3 data-path-to-node=\"12\"\u003e\u003cb data-path-to-node=\"12\" data-index-in-node=\"0\"\u003e3. Frequently Asked Questions (FAQ)\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-path-to-node=\"13\"\u003e\u003cb data-path-to-node=\"13\" data-index-in-node=\"0\"\u003e1. What is the correct torque for the Closed Tray RC Transfer?\u003c\/b\u003e This component should only be tightened \u003cb data-path-to-node=\"13\" data-index-in-node=\"103\"\u003emanually\u003c\/b\u003e to a light finger-tightness of \u003cb data-path-to-node=\"13\" data-index-in-node=\"143\"\u003e5–10 Ncm\u003c\/b\u003e. Do not use a torque wrench to avoid over-tightening.\u003c\/p\u003e\n\u003cp data-path-to-node=\"14\"\u003e\u003cb data-path-to-node=\"14\" data-index-in-node=\"0\"\u003e2. Which driver should I use with this transfer?\u003c\/b\u003e A standard \u003cb data-path-to-node=\"14\" data-index-in-node=\"60\"\u003e1.25 mm hex driver\u003c\/b\u003e is required for seating the transfer screw.\u003c\/p\u003e\n\u003cp data-path-to-node=\"15\"\u003e\u003cb data-path-to-node=\"15\" data-index-in-node=\"0\"\u003e3. Is this compatible with the Open Tray technique?\u003c\/b\u003e No, this specific component (\u003cb data-path-to-node=\"15\" data-index-in-node=\"81\"\u003eAGM-305-RC\u003c\/b\u003e) is designed for \u003cb data-path-to-node=\"15\" data-index-in-node=\"109\"\u003eClosed Tray\u003c\/b\u003e impressions. For Open Tray procedures, please use the corresponding Open Tray RC Transfer.\u003c\/p\u003e","brand":"Alfa Gate","offers":[{"title":"RC PLATFORM \/ TRANSFERS","offer_id":46422841098492,"sku":"AGM-305-RC","price":16.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0657\/2788\/9660\/files\/AGM-305-RC.png?v=1726466747"}],"url":"https:\/\/alfa-gate.ps\/collections\/all-transfers.oembed","provider":"alfa-gate","version":"1.0","type":"link"}