{"product_id":"15-esthetic-angulated-abutment","title":"15° Angulated Esthetic Abutments","description":"\u003cp data-start=\"146\" data-end=\"461\"\u003eThe \u003cstrong\u003e15° Esthetic Angulated Abutment\u003c\/strong\u003e is designed to correct implant angulation while maintaining ideal prosthetic alignment and natural emergence profile. Engineered for SP internal hex systems, it allows clinicians to restore cases with slight implant divergence without compromising esthetics or load distribution.\u003c\/p\u003e\n\u003cp data-start=\"463\" data-end=\"773\"\u003eIts anatomical contour supports soft-tissue adaptation and enhances gingival architecture, making it an excellent solution for anterior restorations and esthetic zones. Manufactured from high-strength medical-grade titanium, it ensures precise fit, mechanical durability, and long-term restorative reliability.\u003c\/p\u003e\n\u003chr data-start=\"775\" data-end=\"778\"\u003e\n\u003ch2 data-start=\"780\" data-end=\"811\"\u003e\u003cstrong data-start=\"783\" data-end=\"811\"\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-start=\"813\" data-end=\"1180\"\u003e\n\u003cli data-start=\"813\" data-end=\"853\"\u003e\n\u003cp data-start=\"815\" data-end=\"853\"\u003e\u003cstrong data-start=\"815\" data-end=\"828\"\u003eMaterial:\u003c\/strong\u003e Medical-grade Titanium\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"854\" data-end=\"877\"\u003e\n\u003cp data-start=\"856\" data-end=\"877\"\u003e\u003cstrong data-start=\"856\" data-end=\"871\"\u003eAngulation:\u003c\/strong\u003e 15°\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"878\" data-end=\"921\"\u003e\n\u003cp data-start=\"880\" data-end=\"921\"\u003e\u003cstrong data-start=\"880\" data-end=\"907\"\u003ePlatform Compatibility:\u003c\/strong\u003e SP Platform\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"922\" data-end=\"959\"\u003e\n\u003cp data-start=\"924\" data-end=\"959\"\u003e\u003cstrong data-start=\"924\" data-end=\"944\"\u003eConnection Type:\u003c\/strong\u003e Internal Hex\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"960\" data-end=\"985\"\u003e\n\u003cp data-start=\"962\" data-end=\"985\"\u003e\u003cstrong data-start=\"962\" data-end=\"975\"\u003eHex Size:\u003c\/strong\u003e 2.42 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"986\" data-end=\"1014\"\u003e\n\u003cp data-start=\"988\" data-end=\"1014\"\u003e\u003cstrong data-start=\"988\" data-end=\"1008\"\u003eInterface Angle:\u003c\/strong\u003e 45°\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1015\" data-end=\"1088\"\u003e\n\u003cp data-start=\"1017\" data-end=\"1052\"\u003e\u003cstrong data-start=\"1017\" data-end=\"1050\"\u003eAvailable Prosthetic Heights:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1055\" data-end=\"1088\"\u003e\n\u003cli data-start=\"1055\" data-end=\"1064\"\u003e\n\u003cp data-start=\"1057\" data-end=\"1064\"\u003e10 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1067\" data-end=\"1076\"\u003e\n\u003cp data-start=\"1069\" data-end=\"1076\"\u003e11 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1079\" data-end=\"1088\"\u003e\n\u003cp data-start=\"1081\" data-end=\"1088\"\u003e12 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1089\" data-end=\"1145\"\u003e\n\u003cp data-start=\"1091\" data-end=\"1112\"\u003e\u003cstrong data-start=\"1091\" data-end=\"1110\"\u003eCollar Heights:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1115\" data-end=\"1145\"\u003e\n\u003cli data-start=\"1115\" data-end=\"1123\"\u003e\n\u003cp data-start=\"1117\" data-end=\"1123\"\u003e1 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1126\" data-end=\"1134\"\u003e\n\u003cp data-start=\"1128\" data-end=\"1134\"\u003e2 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1137\" data-end=\"1145\"\u003e\n\u003cp data-start=\"1139\" data-end=\"1145\"\u003e3 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1146\" data-end=\"1180\"\u003e\n\u003cp data-start=\"1148\" data-end=\"1180\"\u003e\u003cstrong data-start=\"1148\" data-end=\"1171\"\u003eRecommended Torque:\u003c\/strong\u003e 25 Ncm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1182\" data-end=\"1185\"\u003e\n\u003ch2 data-start=\"1187\" data-end=\"1217\"\u003e\u003cstrong data-start=\"1190\" data-end=\"1217\"\u003eKey Features \u0026amp; Benefits\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-start=\"1219\" data-end=\"1523\"\u003e\n\u003cli data-start=\"1219\" data-end=\"1283\"\u003e\n\u003cp data-start=\"1221\" data-end=\"1283\"\u003eCorrects mild implant angulation for optimal prosthetic axis\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1284\" data-end=\"1322\"\u003e\n\u003cp data-start=\"1286\" data-end=\"1322\"\u003eSupports natural emergence profile\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1323\" data-end=\"1371\"\u003e\n\u003cp data-start=\"1325\" data-end=\"1371\"\u003eIdeal for anterior and esthetic restorations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1372\" data-end=\"1423\"\u003e\n\u003cp data-start=\"1374\" data-end=\"1423\"\u003ePrecision internal hex connection for stability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1424\" data-end=\"1477\"\u003e\n\u003cp data-start=\"1426\" data-end=\"1477\"\u003eTitanium construction ensures mechanical strength\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1478\" data-end=\"1523\"\u003e\n\u003cp data-start=\"1480\" data-end=\"1523\"\u003ePromotes predictable restorative outcomes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1525\" data-end=\"1528\"\u003e\n\u003ch2 data-start=\"1530\" data-end=\"1563\"\u003e\u003cstrong data-start=\"1533\" data-end=\"1563\"\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"1565\" data-end=\"1742\"\u003e\u003cstrong data-start=\"1565\" data-end=\"1606\"\u003eQ: When should this abutment be used?\u003c\/strong\u003e\u003cbr data-start=\"1606\" data-end=\"1609\"\u003eA: It is indicated when implant placement results in slight angulation that must be corrected to align the prosthetic crown properly.\u003c\/p\u003e\n\u003cp data-start=\"1744\" data-end=\"1844\"\u003e\u003cstrong data-start=\"1744\" data-end=\"1779\"\u003eQ: What platform is compatible?\u003c\/strong\u003e\u003cbr data-start=\"1779\" data-end=\"1782\"\u003eA: This abutment is compatible with SP platform implants only.\u003c\/p\u003e\n\u003cp data-start=\"1846\" data-end=\"2047\"\u003e\u003cstrong data-start=\"1846\" data-end=\"1920\"\u003eQ: What is the difference between collar height and prosthetic height?\u003c\/strong\u003e\u003cbr data-start=\"1920\" data-end=\"1923\"\u003eA: Collar height relates to soft-tissue thickness; prosthetic height refers to vertical restorative space above the implant.\u003c\/p\u003e\n\u003cp data-start=\"2049\" data-end=\"2144\"\u003e\u003cstrong data-start=\"2049\" data-end=\"2097\"\u003eQ: What torque is recommended for placement?\u003c\/strong\u003e\u003cbr data-start=\"2097\" data-end=\"2100\"\u003eA: Tighten the abutment screw to \u003cstrong data-start=\"2133\" data-end=\"2143\"\u003e25 Ncm\u003c\/strong\u003e.\u003c\/p\u003e","brand":"Alfa Gate","offers":[{"title":"10mm \/ SP PLATFORM \/ ANGULATED ABUTMENTS","offer_id":43731762348284,"sku":"AGM-102-E1","price":28.0,"currency_code":"USD","in_stock":true},{"title":"11mm \/ SP PLATFORM \/ ANGULATED ABUTMENTS","offer_id":43731762381052,"sku":"AGM-102-E2","price":28.0,"currency_code":"USD","in_stock":true},{"title":"12mm \/ SP PLATFORM \/ ANGULATED ABUTMENTS","offer_id":43731771982076,"sku":"AGM-102-E3","price":28.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0657\/2788\/9660\/products\/AGM-102-E1.png?v=1663148653","url":"https:\/\/alfa-gate.ps\/products\/15-esthetic-angulated-abutment","provider":"alfa-gate","version":"1.0","type":"link"}