{"product_id":"angulated-abutment-15","title":"15° Angulated Abutments (NP-RP)","description":"\u003cp data-start=\"128\" data-end=\"650\"\u003eThe \u003cstrong data-start=\"132\" data-end=\"168\"\u003eAlfa Gate 15° Angulated Abutment\u003c\/strong\u003e is designed to correct implant angulation and optimize prosthetic positioning in cases where implant axis alignment is not ideal. Manufactured from high-strength medical-grade titanium and compatible with both \u003cstrong data-start=\"379\" data-end=\"419\"\u003eNarrow and Regular Conical Platforms\u003c\/strong\u003e, it enables precise restoration seating while reducing prosthetic stress and improving aesthetic outcomes. The 15° correction angle allows clinicians to achieve ideal prosthetic emergence without compromising mechanical stability.\u003c\/p\u003e\n\u003chr data-start=\"652\" data-end=\"655\"\u003e\n\u003ch2 data-start=\"657\" data-end=\"688\"\u003e\u003cstrong data-start=\"660\" data-end=\"688\"\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-start=\"689\" data-end=\"1065\"\u003e\n\u003cli data-start=\"689\" data-end=\"733\"\u003e\n\u003cp data-start=\"691\" data-end=\"733\"\u003e\u003cstrong data-start=\"691\" data-end=\"708\"\u003eProduct Name:\u003c\/strong\u003e 15° Angulated Abutment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"759\" data-end=\"893\"\u003e\n\u003cp data-start=\"761\" data-end=\"790\"\u003e\u003cstrong data-start=\"761\" data-end=\"788\"\u003ePlatform Compatibility:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"793\" data-end=\"893\"\u003e\n\u003cli data-start=\"793\" data-end=\"841\"\u003e\n\u003cp data-start=\"795\" data-end=\"841\"\u003eNarrow Conical Platform (NP) — 2.23 mm \/ 22°\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"844\" data-end=\"893\"\u003e\n\u003cp data-start=\"846\" data-end=\"893\"\u003eRegular Conical Platform (RP) — 2.65 mm \/ 22°\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"894\" data-end=\"917\"\u003e\n\u003cp data-start=\"896\" data-end=\"917\"\u003e\u003cstrong data-start=\"896\" data-end=\"911\"\u003eAngulation:\u003c\/strong\u003e 15°\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"918\" data-end=\"956\"\u003e\n\u003cp data-start=\"920\" data-end=\"956\"\u003e\u003cstrong data-start=\"920\" data-end=\"942\"\u003eAvailable Heights:\u003c\/strong\u003e 9 mm, 12 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"957\" data-end=\"997\"\u003e\n\u003cp data-start=\"959\" data-end=\"997\"\u003e\u003cstrong data-start=\"959\" data-end=\"972\"\u003eMaterial:\u003c\/strong\u003e Medical-grade Titanium\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"998\" data-end=\"1030\"\u003e\n\u003cp data-start=\"1000\" data-end=\"1030\"\u003e\u003cstrong data-start=\"1000\" data-end=\"1009\"\u003eType:\u003c\/strong\u003e Angulated Abutment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1031\" data-end=\"1065\"\u003e\n\u003cp data-start=\"1033\" data-end=\"1065\"\u003e\u003cstrong data-start=\"1033\" data-end=\"1056\"\u003eRecommended Torque:\u003c\/strong\u003e 25 Ncm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1067\" data-end=\"1070\"\u003e\n\u003ch2 data-start=\"1072\" data-end=\"1091\"\u003e\u003cstrong data-start=\"1075\" data-end=\"1091\"\u003eKey Features\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-start=\"1092\" data-end=\"1461\"\u003e\n\u003cli data-start=\"1092\" data-end=\"1160\"\u003e\n\u003cp data-start=\"1094\" data-end=\"1160\"\u003e\u003cstrong data-start=\"1094\" data-end=\"1118\"\u003e15° Angle Correction\u003c\/strong\u003e — Compensates for implant misalignment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1161\" data-end=\"1237\"\u003e\n\u003cp data-start=\"1163\" data-end=\"1237\"\u003e\u003cstrong data-start=\"1163\" data-end=\"1192\"\u003eStable Conical Connection\u003c\/strong\u003e — Enhances mechanical locking and sealing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1238\" data-end=\"1328\"\u003e\n\u003cp data-start=\"1240\" data-end=\"1328\"\u003e\u003cstrong data-start=\"1240\" data-end=\"1265\"\u003eTitanium Construction\u003c\/strong\u003e — High strength, corrosion resistance, long-term durability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1329\" data-end=\"1395\"\u003e\n\u003cp data-start=\"1331\" data-end=\"1395\"\u003e\u003cstrong data-start=\"1331\" data-end=\"1359\"\u003eImproved Prosthetic Axis\u003c\/strong\u003e — Allows ideal crown positioning.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1396\" data-end=\"1461\"\u003e\n\u003cp data-start=\"1398\" data-end=\"1461\"\u003e\u003cstrong data-start=\"1398\" data-end=\"1424\"\u003eVersatile Platform Fit\u003c\/strong\u003e — Compatible with NP and RP systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1463\" data-end=\"1466\"\u003e\n\u003ch2 data-start=\"1468\" data-end=\"1494\"\u003e\u003cstrong data-start=\"1471\" data-end=\"1494\"\u003eClinical Advantages\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-start=\"1495\" data-end=\"1763\"\u003e\n\u003cli data-start=\"1495\" data-end=\"1551\"\u003e\n\u003cp data-start=\"1497\" data-end=\"1551\"\u003eFacilitates restoration in angled implant placements\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1552\" data-end=\"1606\"\u003e\n\u003cp data-start=\"1554\" data-end=\"1606\"\u003eReduces need for excessive prosthetic compensation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1607\" data-end=\"1659\"\u003e\n\u003cp data-start=\"1609\" data-end=\"1659\"\u003eSupports aesthetic restoration in anterior zones\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1660\" data-end=\"1701\"\u003e\n\u003cp data-start=\"1662\" data-end=\"1701\"\u003eMaintains favorable load distribution\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1702\" data-end=\"1763\"\u003e\n\u003cp data-start=\"1704\" data-end=\"1763\"\u003eImproves restorative access and screw-channel positioning\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1765\" data-end=\"1768\"\u003e\n\u003ch2 data-start=\"1770\" data-end=\"1788\"\u003e\u003cstrong data-start=\"1773\" data-end=\"1788\"\u003eIndications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-start=\"1789\" data-end=\"1968\"\u003e\n\u003cli data-start=\"1789\" data-end=\"1819\"\u003e\n\u003cp data-start=\"1791\" data-end=\"1819\"\u003eNon-parallel implant cases\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1820\" data-end=\"1873\"\u003e\n\u003cp data-start=\"1822\" data-end=\"1873\"\u003eAnatomical limitations requiring angled placement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1874\" data-end=\"1914\"\u003e\n\u003cp data-start=\"1876\" data-end=\"1914\"\u003eFull-arch or multi-unit restorations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1915\" data-end=\"1968\"\u003e\n\u003cp data-start=\"1917\" data-end=\"1968\"\u003eSingle crowns with compromised implant angulation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1970\" data-end=\"1973\"\u003e\n\u003ch2 data-start=\"1975\" data-end=\"1985\"\u003e\u003cstrong data-start=\"1978\" data-end=\"1985\"\u003eFAQ\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"1987\" data-end=\"2164\"\u003e\u003cstrong data-start=\"1987\" data-end=\"2039\"\u003eQ: When should a 15° angulated abutment be used?\u003c\/strong\u003e\u003cbr data-start=\"2039\" data-end=\"2042\"\u003eA: When implant placement deviates from ideal prosthetic axis and correction is required for proper restoration alignment.\u003c\/p\u003e\n\u003cp data-start=\"2166\" data-end=\"2289\"\u003e\u003cstrong data-start=\"2166\" data-end=\"2206\"\u003eQ: Does angulation affect stability?\u003c\/strong\u003e\u003cbr data-start=\"2206\" data-end=\"2209\"\u003eA: No. The conical interface maintains strong mechanical engagement and sealing.\u003c\/p\u003e\n\u003cp data-start=\"2291\" data-end=\"2409\"\u003e\u003cstrong data-start=\"2291\" data-end=\"2343\"\u003eQ: Is it compatible with all Alfa Gate implants?\u003c\/strong\u003e\u003cbr data-start=\"2343\" data-end=\"2346\"\u003eA: It fits Alfa Gate implants using NP or RP conical platforms.\u003c\/p\u003e\n\u003cp data-start=\"2411\" data-end=\"2505\"\u003e\u003cstrong data-start=\"2411\" data-end=\"2445\"\u003eQ: What torque is recommended?\u003c\/strong\u003e\u003cbr data-start=\"2445\" data-end=\"2448\"\u003eA: Tighten to \u003cstrong data-start=\"2462\" data-end=\"2472\"\u003e25 Ncm\u003c\/strong\u003e with a calibrated torque wrench.\u003c\/p\u003e","brand":"Alfa Gate","offers":[{"title":"NARROW CONICAL PLATFORM \/ 9mm \/ ANGULATED ABUTMENTS","offer_id":43722019143932,"sku":"AAC-159-NP","price":28.0,"currency_code":"USD","in_stock":true},{"title":"NARROW CONICAL PLATFORM \/ 12mm \/ ANGULATED ABUTMENTS","offer_id":43722019176700,"sku":"AAC-1512-NP","price":28.0,"currency_code":"USD","in_stock":true},{"title":"REGULAR CONICAL PLATFORM \/ 9mm \/ ANGULATED ABUTMENTS","offer_id":43722019209468,"sku":"AAC-159-RP","price":28.0,"currency_code":"USD","in_stock":true},{"title":"REGULAR CONICAL PLATFORM \/ 12mm \/ ANGULATED ABUTMENTS","offer_id":43722019242236,"sku":"AAC-1512-RP","price":28.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0657\/2788\/9660\/products\/AAC-159-NP.png?v=1662965956","url":"https:\/\/alfa-gate.ps\/products\/angulated-abutment-15","provider":"alfa-gate","version":"1.0","type":"link"}