{"product_id":"copy-of-s-line-transfer-for-open-tray-impression","title":"CLOSE TRAY IMPRESSION SCREW CONNECTION","description":"\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003ciframe title=\"Implant impression taking- open tray | Alfa Gate\" src=\"https:\/\/www.youtube.com\/embed\/ZjrKAG0hzWU\" height=\"720\" width=\"1280\"\u003e\u003c\/iframe\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp data-start=\"356\" data-end=\"689\"\u003eThe \u003cstrong data-start=\"360\" data-end=\"402\"\u003eClose Tray Impression Screw Connection\u003c\/strong\u003e is designed for accurate and efficient \u003cstrong data-start=\"442\" data-end=\"479\"\u003eclosed-tray impression procedures\u003c\/strong\u003e on \u003cstrong data-start=\"483\" data-end=\"509\"\u003e3.0 mm S-Line implants\u003c\/strong\u003e.\u003cbr data-start=\"510\" data-end=\"513\"\u003eIt ensures stable positioning during impression taking while allowing easy removal after tray separation, supporting predictable transfer of implant position to the laboratory.\u003c\/p\u003e\n\u003chr data-start=\"691\" data-end=\"694\"\u003e\n\u003ch2 data-start=\"696\" data-end=\"726\"\u003e Technical Specifications\u003c\/h2\u003e\n\u003cul data-start=\"728\" data-end=\"1119\"\u003e\n\u003cli data-start=\"728\" data-end=\"772\"\u003e\n\u003cp data-start=\"730\" data-end=\"772\"\u003e\u003cstrong data-start=\"730\" data-end=\"743\"\u003ePlatform:\u003c\/strong\u003e S-Line (3.0 mm internal hex)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"773\" data-end=\"837\"\u003e\n\u003cp data-start=\"775\" data-end=\"837\"\u003e\u003cstrong data-start=\"775\" data-end=\"795\"\u003eConnection Type:\u003c\/strong\u003e Internal hex (S-Line straight connection)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"838\" data-end=\"869\"\u003e\n\u003cp data-start=\"840\" data-end=\"869\"\u003e\u003cstrong data-start=\"840\" data-end=\"853\"\u003eMaterial:\u003c\/strong\u003e Stainless steel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"870\" data-end=\"929\"\u003e\n\u003cp data-start=\"872\" data-end=\"929\"\u003e\u003cstrong data-start=\"872\" data-end=\"897\"\u003eImpression Technique:\u003c\/strong\u003e Close tray (indirect technique)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"930\" data-end=\"1016\"\u003e\n\u003cp data-start=\"932\" data-end=\"1016\"\u003e\u003cstrong data-start=\"932\" data-end=\"955\"\u003eRecommended Torque:\u003c\/strong\u003e\u003cbr data-start=\"955\" data-end=\"958\"\u003eManual tightening only — light finger-tight \u003cstrong data-start=\"1004\" data-end=\"1016\"\u003e5–10 Ncm\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1017\" data-end=\"1063\"\u003e\n\u003cp data-start=\"1019\" data-end=\"1063\"\u003e\u003cstrong data-start=\"1019\" data-end=\"1044\"\u003eDriver Compatibility:\u003c\/strong\u003e Hex driver 1.25 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1064\" data-end=\"1097\"\u003e\n\u003cp data-start=\"1066\" data-end=\"1097\"\u003e\u003cstrong data-start=\"1066\" data-end=\"1084\"\u003eSterilization:\u003c\/strong\u003e Autoclavable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1098\" data-end=\"1119\"\u003e\n\u003cp data-start=\"1100\" data-end=\"1119\"\u003e\u003cstrong data-start=\"1100\" data-end=\"1108\"\u003eSKU:\u003c\/strong\u003e AGM-303-SL\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1121\" data-end=\"1124\"\u003e\n\u003ch2 data-start=\"1126\" data-end=\"1164\"\u003eKey Features \u0026amp; Clinical Benefits\u003c\/h2\u003e\n\u003cul data-start=\"1166\" data-end=\"1791\"\u003e\n\u003cli data-start=\"1166\" data-end=\"1289\"\u003e\n\u003cp data-start=\"1168\" data-end=\"1289\"\u003e\u003cstrong data-start=\"1168\" data-end=\"1212\"\u003eAccurate Closed-Tray Impression Transfer\u003c\/strong\u003e\u003cbr data-start=\"1212\" data-end=\"1215\"\u003eDesigned to maintain precise implant position during impression removal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1291\" data-end=\"1448\"\u003e\n\u003cp data-start=\"1293\" data-end=\"1448\"\u003e\u003cstrong data-start=\"1293\" data-end=\"1341\"\u003eOptimized for S-Line Internal Hex Connection\u003c\/strong\u003e\u003cbr data-start=\"1341\" data-end=\"1344\"\u003eFully compatible with \u003cstrong data-start=\"1368\" data-end=\"1407\"\u003eS-Line 2.0 mm internal hex geometry\u003c\/strong\u003e, ensuring correct seating and stability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1450\" data-end=\"1561\"\u003e\n\u003cp data-start=\"1452\" data-end=\"1561\"\u003e\u003cstrong data-start=\"1452\" data-end=\"1484\"\u003eControlled Manual Tightening\u003c\/strong\u003e\u003cbr data-start=\"1484\" data-end=\"1487\"\u003eLight finger-tight protocol prevents thread damage and over-compression.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1563\" data-end=\"1680\"\u003e\n\u003cp data-start=\"1565\" data-end=\"1680\"\u003e\u003cstrong data-start=\"1565\" data-end=\"1605\"\u003eDurable Stainless Steel Construction\u003c\/strong\u003e\u003cbr data-start=\"1605\" data-end=\"1608\"\u003eProvides dimensional stability and repeated sterilization reliability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1682\" data-end=\"1791\"\u003e\n\u003cp data-start=\"1684\" data-end=\"1791\"\u003e\u003cstrong data-start=\"1684\" data-end=\"1711\"\u003eEasy Handling \u0026amp; Removal\u003c\/strong\u003e\u003cbr data-start=\"1711\" data-end=\"1714\"\u003eFacilitates smooth impression procedures with minimal chairside complexity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1793\" data-end=\"1796\"\u003e\n\u003ch2 data-start=\"1798\" data-end=\"1836\"\u003eFrequently Asked Questions (FAQ)\u003c\/h2\u003e\n\u003cp data-start=\"1838\" data-end=\"2026\"\u003e\u003cstrong data-start=\"1838\" data-end=\"1901\"\u003eQ: Which implants is this impression screw compatible with?\u003c\/strong\u003e\u003cbr data-start=\"1901\" data-end=\"1904\"\u003eA: It is compatible exclusively with \u003cstrong data-start=\"1941\" data-end=\"1988\"\u003eAlfa Gate S-Line implants (3.0 mm platform)\u003c\/strong\u003e featuring an internal hex connection.\u003c\/p\u003e\n\u003cp data-start=\"2028\" data-end=\"2175\"\u003e\u003cstrong data-start=\"2028\" data-end=\"2089\"\u003eQ: Is this used for open-tray or closed-tray impressions?\u003c\/strong\u003e\u003cbr data-start=\"2089\" data-end=\"2092\"\u003eA: This component is designed for \u003cstrong data-start=\"2126\" data-end=\"2174\"\u003eclosed-tray (indirect) impression techniques\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"2177\" data-end=\"2305\"\u003e\u003cstrong data-start=\"2177\" data-end=\"2229\"\u003eQ: Can I torque this screw with a torque wrench?\u003c\/strong\u003e\u003cbr data-start=\"2229\" data-end=\"2232\"\u003eA: No. Only \u003cstrong data-start=\"2244\" data-end=\"2289\"\u003emanual finger-tight tightening (5–10 Ncm)\u003c\/strong\u003e is recommended.\u003c\/p\u003e\n\u003cp data-start=\"2307\" data-end=\"2378\"\u003e\u003cstrong data-start=\"2307\" data-end=\"2342\"\u003eQ: Which driver should be used?\u003c\/strong\u003e\u003cbr data-start=\"2342\" data-end=\"2345\"\u003eA: A \u003cstrong data-start=\"2350\" data-end=\"2377\"\u003e1.25 mm hex hand driver\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"2380\" data-end=\"2487\"\u003e\u003cstrong data-start=\"2380\" data-end=\"2416\"\u003eQ: Can this component be reused?\u003c\/strong\u003e\u003cbr data-start=\"2416\" data-end=\"2419\"\u003eA: Yes. It is made of stainless steel and is \u003cstrong data-start=\"2464\" data-end=\"2486\"\u003efully autoclavable\u003c\/strong\u003e.\u003c\/p\u003e","brand":"Alfa Gate","offers":[{"title":"11mm \/ S-LINE PLATFORM \/ TRANSFERS","offer_id":44693805465852,"sku":"AGM-303-SL","price":18.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0657\/2788\/9660\/files\/AGM-303-SLforclosetrayimpressionscrewconnection_e82c9bdc-964f-4c5f-8948-ff3ca96de8d8.png?v=1697715670","url":"https:\/\/alfa-gate.ps\/products\/copy-of-s-line-transfer-for-open-tray-impression","provider":"alfa-gate","version":"1.0","type":"link"}