{"product_id":"implant-transfer-rp","title":"Implant transfer RP","description":"\u003cp data-start=\"108\" data-end=\"435\"\u003eThe \u003cstrong data-start=\"112\" data-end=\"145\"\u003eAlfa Gate Implant Transfer RP\u003c\/strong\u003e is a precision impression coping designed for accurate implant position transfer in conventional impression workflows. Compatible with the \u003cstrong data-start=\"285\" data-end=\"318\"\u003eConical Regular Platform (RP)\u003c\/strong\u003e, it ensures reliable replication of implant orientation and depth from the clinical setting to the laboratory model.\u003c\/p\u003e\n\u003cp data-start=\"437\" data-end=\"540\"\u003eAvailable in \u003cstrong data-start=\"450\" data-end=\"465\"\u003eClosed Tray\u003c\/strong\u003e and \u003cstrong data-start=\"470\" data-end=\"483\"\u003eOpen Tray\u003c\/strong\u003e configurations to support different clinical techniques.\u003c\/p\u003e\n\u003chr data-start=\"542\" data-end=\"545\"\u003e\n\u003ch2 data-start=\"547\" data-end=\"574\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul data-start=\"576\" data-end=\"1013\"\u003e\n\u003cli data-start=\"576\" data-end=\"617\"\u003e\n\u003cp data-start=\"578\" data-end=\"617\"\u003e\u003cstrong data-start=\"578\" data-end=\"595\"\u003eProduct Name:\u003c\/strong\u003e Implant Transfer RP\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"618\" data-end=\"637\"\u003e\n\u003cp data-start=\"620\" data-end=\"637\"\u003e\u003cstrong data-start=\"620\" data-end=\"628\"\u003eSKU:\u003c\/strong\u003e ITK-RP \/ \u003cspan\u003eITC-RP\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"831\" data-end=\"862\"\u003e\n\u003cp data-start=\"833\" data-end=\"862\"\u003e\u003cstrong data-start=\"833\" data-end=\"852\"\u003eInterface size:\u003c\/strong\u003e 2.65 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"863\" data-end=\"881\"\u003e\n\u003cp data-start=\"865\" data-end=\"881\"\u003e\u003cstrong data-start=\"865\" data-end=\"875\"\u003eAngle:\u003c\/strong\u003e 22°\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"882\" data-end=\"964\"\u003e\n\u003cp data-start=\"884\" data-end=\"910\"\u003e\u003cstrong data-start=\"884\" data-end=\"908\"\u003eCompatible families:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"913\" data-end=\"964\"\u003e\n\u003cli data-start=\"913\" data-end=\"922\"\u003e\n\u003cp data-start=\"915\" data-end=\"922\"\u003eM+ RP\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"925\" data-end=\"964\"\u003e\n\u003cp data-start=\"927\" data-end=\"964\"\u003eOther RP conical systems (non-TRIO)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"700\" data-end=\"732\"\u003e\n\u003cp data-start=\"702\" data-end=\"732\"\u003e\u003cstrong data-start=\"702\" data-end=\"722\"\u003eConnection Type:\u003c\/strong\u003e Conical\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"733\" data-end=\"766\"\u003e\n\u003cp data-start=\"735\" data-end=\"766\"\u003e\u003cstrong data-start=\"735\" data-end=\"748\"\u003eMaterial:\u003c\/strong\u003e Stainless Steel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"767\" data-end=\"860\"\u003e\n\u003cp data-start=\"769\" data-end=\"792\"\u003e\u003cstrong data-start=\"769\" data-end=\"790\"\u003eAvailable Styles:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"795\" data-end=\"860\"\u003e\n\u003cli data-start=\"795\" data-end=\"827\"\u003e\n\u003cp data-start=\"797\" data-end=\"827\"\u003eClosed Tray Implant Transfer\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"830\" data-end=\"860\"\u003e\n\u003cp data-start=\"832\" data-end=\"860\"\u003eOpen Tray Implant Transfer\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"861\" data-end=\"896\"\u003e\n\u003cp data-start=\"863\" data-end=\"896\"\u003e\u003cstrong data-start=\"863\" data-end=\"874\"\u003eDriver:\u003c\/strong\u003e 1.25 mm Hand Driver\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"897\" data-end=\"968\"\u003e\n\u003cp data-start=\"899\" data-end=\"968\"\u003e\u003cstrong data-start=\"899\" data-end=\"922\"\u003eRecommended Torque:\u003c\/strong\u003e Manual only — light finger-tight (5–10 Ncm)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"969\" data-end=\"1013\"\u003e\n\u003cp data-start=\"971\" data-end=\"1013\"\u003e\u003cstrong data-start=\"971\" data-end=\"980\"\u003eType:\u003c\/strong\u003e Transfers \/ Impression Copings\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1015\" data-end=\"1018\"\u003e\n\u003ch2 data-start=\"1020\" data-end=\"1046\"\u003eKey Features \u0026amp; Benefits\u003c\/h2\u003e\n\u003cul data-start=\"1048\" data-end=\"1536\"\u003e\n\u003cli data-start=\"1048\" data-end=\"1143\"\u003e\n\u003cp data-start=\"1050\" data-end=\"1143\"\u003e\u003cstrong data-start=\"1050\" data-end=\"1087\"\u003eAccurate Implant Position Capture\u003c\/strong\u003e — Ensures precise transfer of 3D implant orientation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1144\" data-end=\"1234\"\u003e\n\u003cp data-start=\"1146\" data-end=\"1234\"\u003e\u003cstrong data-start=\"1146\" data-end=\"1182\"\u003eConical Connection Compatibility\u003c\/strong\u003e — Designed specifically for RP conical interface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1235\" data-end=\"1349\"\u003e\n\u003cp data-start=\"1237\" data-end=\"1349\"\u003e\u003cstrong data-start=\"1237\" data-end=\"1267\"\u003eHigh Dimensional Stability\u003c\/strong\u003e — Stainless steel construction resists distortion during impression procedures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1350\" data-end=\"1459\"\u003e\n\u003cp data-start=\"1352\" data-end=\"1459\"\u003e\u003cstrong data-start=\"1352\" data-end=\"1377\"\u003eTechnique Versatility\u003c\/strong\u003e — Supports both closed-tray (repositioning) and open-tray (pick-up) techniques.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1460\" data-end=\"1536\"\u003e\n\u003cp data-start=\"1462\" data-end=\"1536\"\u003e\u003cstrong data-start=\"1462\" data-end=\"1480\"\u003eSecure Seating\u003c\/strong\u003e — Stable engagement reduces risk of rotational error.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1538\" data-end=\"1541\"\u003e\n\u003ch2 data-start=\"1543\" data-end=\"1566\"\u003eClinical Indications\u003c\/h2\u003e\n\u003cul data-start=\"1568\" data-end=\"1729\"\u003e\n\u003cli data-start=\"1568\" data-end=\"1596\"\u003e\n\u003cp data-start=\"1570\" data-end=\"1596\"\u003eSingle-unit restorations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1597\" data-end=\"1631\"\u003e\n\u003cp data-start=\"1599\" data-end=\"1631\"\u003eMulti-unit prosthetic planning\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1632\" data-end=\"1664\"\u003e\n\u003cp data-start=\"1634\" data-end=\"1664\"\u003eCrown and bridge fabrication\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1665\" data-end=\"1696\"\u003e\n\u003cp data-start=\"1667\" data-end=\"1696\"\u003eAnalog impression workflows\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1697\" data-end=\"1729\"\u003e\n\u003cp data-start=\"1699\" data-end=\"1729\"\u003eLaboratory model fabrication\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1731\" data-end=\"1734\"\u003e\n\u003ch2 data-start=\"1736\" data-end=\"1763\"\u003eClosed Tray vs Open Tray\u003c\/h2\u003e\n\u003cp data-start=\"1765\" data-end=\"1789\"\u003e\u003cstrong data-start=\"1765\" data-end=\"1789\"\u003eClosed Tray Transfer\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1790\" data-end=\"1919\"\u003e\n\u003cli data-start=\"1790\" data-end=\"1822\"\u003e\n\u003cp data-start=\"1792\" data-end=\"1822\"\u003eSuitable for single implants\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1823\" data-end=\"1879\"\u003e\n\u003cp data-start=\"1825\" data-end=\"1879\"\u003eRequires repositioning into impression after removal\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1880\" data-end=\"1919\"\u003e\n\u003cp data-start=\"1882\" data-end=\"1919\"\u003eEfficient for straightforward cases\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1921\" data-end=\"1943\"\u003e\u003cstrong data-start=\"1921\" data-end=\"1943\"\u003eOpen Tray Transfer\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1944\" data-end=\"2089\"\u003e\n\u003cli data-start=\"1944\" data-end=\"1981\"\u003e\n\u003cp data-start=\"1946\" data-end=\"1981\"\u003eRecommended for multiple implants\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1982\" data-end=\"2034\"\u003e\n\u003cp data-start=\"1984\" data-end=\"2034\"\u003ePick-up technique for higher positional accuracy\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2035\" data-end=\"2089\"\u003e\n\u003cp data-start=\"2037\" data-end=\"2089\"\u003eIdeal for full-arch or parallelism-sensitive cases\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2091\" data-end=\"2094\"\u003e\n\u003ch2 data-start=\"2096\" data-end=\"2102\"\u003eFAQ\u003c\/h2\u003e\n\u003cp data-start=\"2104\" data-end=\"2229\"\u003e\u003cstrong data-start=\"2104\" data-end=\"2151\"\u003eQ: Can this transfer be torqued clinically?\u003c\/strong\u003e\u003cbr data-start=\"2151\" data-end=\"2154\"\u003eNo. It should be tightened manually (5–10 Ncm) using a 1.25 mm hand driver.\u003c\/p\u003e\n\u003cp data-start=\"2231\" data-end=\"2346\"\u003e\u003cstrong data-start=\"2231\" data-end=\"2272\"\u003eQ: Is it compatible with NP implants?\u003c\/strong\u003e\u003cbr data-start=\"2272\" data-end=\"2275\"\u003eNo. This version is specifically for the Conical Regular Platform (RP).\u003c\/p\u003e\n\u003cp data-start=\"2348\" data-end=\"2450\"\u003e\u003cstrong data-start=\"2348\" data-end=\"2377\"\u003eQ: What material is used?\u003c\/strong\u003e\u003cbr data-start=\"2377\" data-end=\"2380\"\u003eHigh-quality stainless steel for dimensional stability and durability.\u003c\/p\u003e","brand":"Alfa Gate","offers":[{"title":"CLOSE TRAY implant transfer \/ REGULAR CONICAL PLATFORM \/ TRANSFERS","offer_id":43731444465916,"sku":"ITK-RP","price":30.0,"currency_code":"USD","in_stock":true},{"title":"Open tray implant transfer \/ REGULAR CONICAL PLATFORM \/ TRANSFERS","offer_id":43731444498684,"sku":"ITC-RP","price":23.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0657\/2788\/9660\/products\/ITC-RP.png?v=1663141025","url":"https:\/\/alfa-gate.ps\/products\/implant-transfer-rp","provider":"alfa-gate","version":"1.0","type":"link"}