{"product_id":"multi-unit-analog-temporary-peek-cylinder","title":"Multi-Unit Temporary PEEK cylinder","description":"\u003cp data-start=\"347\" data-end=\"715\"\u003eThe \u003cstrong data-start=\"351\" data-end=\"389\"\u003eMulti-Unit Temporary PEEK Cylinder\u003c\/strong\u003e is a prosthetic component designed for the fabrication of \u003cstrong data-start=\"448\" data-end=\"485\"\u003etemporary multi-unit restorations\u003c\/strong\u003e on implant-supported cases.\u003cbr data-start=\"513\" data-end=\"516\"\u003eManufactured from high-performance \u003cstrong data-start=\"551\" data-end=\"559\"\u003ePEEK\u003c\/strong\u003e, it provides excellent machinability, stability, and resistance during provisionalization phases, making it ideal for immediate or short-term restorations.\u003c\/p\u003e\n\u003cp data-start=\"717\" data-end=\"873\"\u003eThis cylinder supports \u003cstrong data-start=\"740\" data-end=\"775\"\u003emulti-unit prosthetic workflows\u003c\/strong\u003e and is compatible with \u003cstrong data-start=\"799\" data-end=\"838\"\u003eSP Platform and RC Platform systems\u003c\/strong\u003e, depending on the selected option.\u003c\/p\u003e\n\u003chr data-start=\"875\" data-end=\"878\"\u003e\n\u003ch2 data-start=\"880\" data-end=\"911\"\u003e\u003cstrong data-start=\"883\" data-end=\"911\"\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-start=\"913\" data-end=\"1330\"\u003e\n\u003cli data-start=\"913\" data-end=\"964\"\u003e\n\u003cp data-start=\"915\" data-end=\"964\"\u003e\u003cstrong data-start=\"915\" data-end=\"932\"\u003eProduct Type:\u003c\/strong\u003e Multi-Unit Temporary Cylinder\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"965\" data-end=\"986\"\u003e\n\u003cp data-start=\"967\" data-end=\"986\"\u003e\u003cstrong data-start=\"967\" data-end=\"978\"\u003eHeight:\u003c\/strong\u003e 12 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"987\" data-end=\"1034\"\u003e\n\u003cp data-start=\"989\" data-end=\"1034\"\u003e\u003cstrong data-start=\"989\" data-end=\"1002\"\u003eMaterial:\u003c\/strong\u003e PEEK (Polyether Ether Ketone)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1035\" data-end=\"1083\"\u003e\n\u003cp data-start=\"1037\" data-end=\"1083\"\u003e\u003cstrong data-start=\"1037\" data-end=\"1057\"\u003eProsthetic Type:\u003c\/strong\u003e Temporary \/ Provisional\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1084\" data-end=\"1198\"\u003e\n\u003cp data-start=\"1086\" data-end=\"1112\"\u003e\u003cstrong data-start=\"1086\" data-end=\"1110\"\u003ePlatforms Available:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1115\" data-end=\"1198\"\u003e\n\u003cli data-start=\"1115\" data-end=\"1155\"\u003e\n\u003cp data-start=\"1117\" data-end=\"1155\"\u003eSP Platform (Internal Hex – 2.42 mm)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1158\" data-end=\"1198\"\u003e\n\u003cp data-start=\"1160\" data-end=\"1198\"\u003eRC Platform (TRIO Morse Taper – 11°)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1199\" data-end=\"1295\"\u003e\n\u003cp data-start=\"1201\" data-end=\"1226\"\u003e\u003cstrong data-start=\"1201\" data-end=\"1224\"\u003eRecommended Torque:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1229\" data-end=\"1295\"\u003e\n\u003cli data-start=\"1229\" data-end=\"1263\"\u003e\n\u003cp data-start=\"1231\" data-end=\"1263\"\u003ePlastic tightening: \u003cstrong data-start=\"1251\" data-end=\"1261\"\u003e15 Ncm\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1266\" data-end=\"1295\"\u003e\n\u003cp data-start=\"1268\" data-end=\"1295\"\u003eTemporary use: \u003cstrong data-start=\"1283\" data-end=\"1293\"\u003e20 Ncm\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1296\" data-end=\"1330\"\u003e\n\u003cp data-start=\"1298\" data-end=\"1330\"\u003e\u003cstrong data-start=\"1298\" data-end=\"1309\"\u003eDriver:\u003c\/strong\u003e Hex driver 1.25 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1332\" data-end=\"1335\"\u003e\n\u003ch2 data-start=\"1337\" data-end=\"1367\"\u003e\u003cstrong data-start=\"1340\" data-end=\"1367\"\u003eKey Features \u0026amp; Benefits\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-start=\"1369\" data-end=\"1981\"\u003e\n\u003cli data-start=\"1369\" data-end=\"1494\"\u003e\n\u003cp data-start=\"1371\" data-end=\"1494\"\u003e\u003cstrong data-start=\"1371\" data-end=\"1423\"\u003eDesigned for multi-unit provisional restorations\u003c\/strong\u003e\u003cbr data-start=\"1423\" data-end=\"1426\"\u003eIdeal for temporary bridges and full-arch provisional prosthetics.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1496\" data-end=\"1619\"\u003e\n\u003cp data-start=\"1498\" data-end=\"1619\"\u003e\u003cstrong data-start=\"1498\" data-end=\"1532\"\u003eHigh-performance PEEK material\u003c\/strong\u003e\u003cbr data-start=\"1532\" data-end=\"1535\"\u003eLightweight, biocompatible, and resistant to deformation during temporary loading.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1621\" data-end=\"1713\"\u003e\n\u003cp data-start=\"1623\" data-end=\"1713\"\u003e\u003cstrong data-start=\"1623\" data-end=\"1650\"\u003eExcellent machinability\u003c\/strong\u003e\u003cbr data-start=\"1650\" data-end=\"1653\"\u003eEasy to modify, shape, and adjust chairside or in the lab.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1715\" data-end=\"1822\"\u003e\n\u003cp data-start=\"1717\" data-end=\"1822\"\u003e\u003cstrong data-start=\"1717\" data-end=\"1745\"\u003eControlled torque values\u003c\/strong\u003e\u003cbr data-start=\"1745\" data-end=\"1748\"\u003eOptimized for provisional stability while protecting implant interfaces.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1824\" data-end=\"1981\"\u003e\n\u003cp data-start=\"1826\" data-end=\"1981\"\u003e\u003cstrong data-start=\"1826\" data-end=\"1861\"\u003ePlatform-specific compatibility\u003c\/strong\u003e\u003cbr data-start=\"1861\" data-end=\"1864\"\u003eAvailable for \u003cstrong data-start=\"1880\" data-end=\"1907\"\u003eSP internal hex systems\u003c\/strong\u003e and \u003cstrong data-start=\"1912\" data-end=\"1941\"\u003eRC (TRIO) conical systems\u003c\/strong\u003e, ensuring correct interface engagement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1983\" data-end=\"1986\"\u003e\n\u003ch2 data-start=\"1988\" data-end=\"2027\"\u003e\u003cstrong data-start=\"1991\" data-end=\"2027\"\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"2029\" data-end=\"2175\"\u003e\u003cstrong data-start=\"2029\" data-end=\"2090\"\u003eQ1: Is this cylinder intended for permanent restorations?\u003c\/strong\u003e\u003cbr data-start=\"2090\" data-end=\"2093\"\u003eNo. This component is designed \u003cstrong data-start=\"2124\" data-end=\"2174\"\u003eonly for temporary or provisional restorations\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"2177\" data-end=\"2228\"\u003e\u003cstrong data-start=\"2177\" data-end=\"2226\"\u003eQ2: What torque should be applied during use?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2229\" data-end=\"2306\"\u003e\n\u003cli data-start=\"2229\" data-end=\"2262\"\u003e\n\u003cp data-start=\"2231\" data-end=\"2262\"\u003e15 Ncm for plastic tightening\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2263\" data-end=\"2306\"\u003e\n\u003cp data-start=\"2265\" data-end=\"2306\"\u003eUp to 20 Ncm for temporary prosthetic use\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2308\" data-end=\"2379\"\u003e\u003cstrong data-start=\"2308\" data-end=\"2346\"\u003eQ3: Which platforms are supported?\u003c\/strong\u003e\u003cbr data-start=\"2346\" data-end=\"2349\"\u003eThe cylinder is available for:\u003c\/p\u003e\n\u003cul data-start=\"2380\" data-end=\"2463\"\u003e\n\u003cli data-start=\"2380\" data-end=\"2422\"\u003e\n\u003cp data-start=\"2382\" data-end=\"2422\"\u003e\u003cstrong data-start=\"2382\" data-end=\"2420\"\u003eSP Platform (Internal Hex 2.42 mm)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2423\" data-end=\"2463\"\u003e\n\u003cp data-start=\"2425\" data-end=\"2463\"\u003e\u003cstrong data-start=\"2425\" data-end=\"2463\"\u003eRC Platform (TRIO Morse taper 11°)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2465\" data-end=\"2537\"\u003e\u003cstrong data-start=\"2465\" data-end=\"2497\"\u003eQ4: What driver is required?\u003c\/strong\u003e\u003cbr data-start=\"2497\" data-end=\"2500\"\u003eA \u003cstrong data-start=\"2502\" data-end=\"2524\"\u003e1.25 mm hex driver\u003c\/strong\u003e is required.\u003c\/p\u003e\n\u003cp data-start=\"2539\" data-end=\"2675\"\u003e\u003cstrong data-start=\"2539\" data-end=\"2596\"\u003eQ5: Can this be used for full-arch provisional cases?\u003c\/strong\u003e\u003cbr data-start=\"2596\" data-end=\"2599\"\u003eYes. It is suitable for \u003cstrong data-start=\"2623\" data-end=\"2674\"\u003emulti-unit and full-arch temporary restorations\u003c\/strong\u003e.\u003c\/p\u003e","brand":"Alfa Gate","offers":[{"title":"SP PLATFORM \/ MULTI-UNIT","offer_id":44997421793532,"sku":"AGM-512","price":19.9,"currency_code":"USD","in_stock":true},{"title":"RC PLATFORM \/ MULTI-UNIT","offer_id":46423806443772,"sku":"AGM-512","price":19.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0657\/2788\/9660\/files\/MULTIUNIT-PROSTHETICS.png?v=1706008728","url":"https:\/\/alfa-gate.ps\/products\/multi-unit-analog-temporary-peek-cylinder","provider":"alfa-gate","version":"1.0","type":"link"}