{"product_id":"plastic-abutment-with-hex-np","title":"Plastic Abutment (With Hex) (NP)","description":"\u003cp data-start=\"339\" data-end=\"687\"\u003eThe Alfa Gate Plastic Abutment (With Hex) for \u003cstrong data-start=\"385\" data-end=\"415\"\u003eM+ Conical Narrow Platform\u003c\/strong\u003e is a \u003cstrong data-start=\"421\" data-end=\"452\"\u003etemporary engaging abutment\u003c\/strong\u003e designed for provisional restorations on Alfa Gate’s \u003cstrong data-start=\"506\" data-end=\"540\"\u003eM+ conical connection implants\u003c\/strong\u003e. The engaging hex provides anti-rotational stability, making it suitable for controlled provisional restorations, especially in single-unit cases.\u003c\/p\u003e\n\u003chr data-start=\"689\" data-end=\"692\"\u003e\n\u003ch3 data-start=\"694\" data-end=\"724\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul data-start=\"725\" data-end=\"1320\"\u003e\n\u003cli data-start=\"725\" data-end=\"789\"\u003e\n\u003cp data-start=\"727\" data-end=\"789\"\u003e\u003cstrong data-start=\"727\" data-end=\"744\"\u003eProduct type:\u003c\/strong\u003e Plastic abutment (temporary \/ provisional)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"790\" data-end=\"835\"\u003e\n\u003cp data-start=\"792\" data-end=\"835\"\u003e\u003cstrong data-start=\"792\" data-end=\"811\"\u003eImplant system:\u003c\/strong\u003e M+ Conical Narrow Platform \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"836\" data-end=\"869\"\u003e\n\u003cp data-start=\"838\" data-end=\"869\"\u003e\u003cstrong data-start=\"838\" data-end=\"851\"\u003ePlatform:\u003c\/strong\u003e Narrow Platform\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"870\" data-end=\"931\"\u003e\n\u003cp data-start=\"872\" data-end=\"931\"\u003e\u003cstrong data-start=\"872\" data-end=\"892\"\u003eConnection type:\u003c\/strong\u003e Conical connection with engaging hex\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"932\" data-end=\"970\"\u003e\n\u003cp data-start=\"934\" data-end=\"970\"\u003e\u003cstrong data-start=\"934\" data-end=\"952\"\u003eConical angle:\u003c\/strong\u003e 11° Morse taper\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"971\" data-end=\"1024\"\u003e\n\u003cp data-start=\"973\" data-end=\"1024\"\u003e\u003cstrong data-start=\"973\" data-end=\"992\"\u003eInterface size:\u003c\/strong\u003e 2.5 mm (RC conical interface)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1025\" data-end=\"1050\"\u003e\n\u003cp data-start=\"1027\" data-end=\"1050\"\u003e\u003cstrong data-start=\"1027\" data-end=\"1040\"\u003eMaterial:\u003c\/strong\u003e Plastic\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1051\" data-end=\"1089\"\u003e\n\u003cp data-start=\"1053\" data-end=\"1089\"\u003e\u003cstrong data-start=\"1053\" data-end=\"1072\"\u003eRetention type:\u003c\/strong\u003e Screw-retained\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1090\" data-end=\"1124\"\u003e\n\u003cp data-start=\"1092\" data-end=\"1124\"\u003e\u003cstrong data-start=\"1092\" data-end=\"1115\"\u003eRecommended torque:\u003c\/strong\u003e 25 Ncm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1125\" data-end=\"1175\"\u003e\n\u003cp data-start=\"1127\" data-end=\"1175\"\u003e\u003cstrong data-start=\"1127\" data-end=\"1145\"\u003eSupplied with:\u003c\/strong\u003e Prosthetic screw AGM-202-RP\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1176\" data-end=\"1239\"\u003e\n\u003cp data-start=\"1178\" data-end=\"1239\"\u003e\u003cstrong data-start=\"1178\" data-end=\"1193\"\u003eIndication:\u003c\/strong\u003e Temporary restorations \/ provisional crowns\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1240\" data-end=\"1320\"\u003e\n\u003cp data-start=\"1242\" data-end=\"1320\"\u003e\u003cstrong data-start=\"1242\" data-end=\"1267\"\u003eSystem compatibility:\u003c\/strong\u003e Alfa Gate M+ conical narrow platform implants only\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1322\" data-end=\"1325\"\u003e\n\u003ch3 data-start=\"1327\" data-end=\"1356\"\u003eKey Features \u0026amp; Benefits\u003c\/h3\u003e\n\u003cul data-start=\"1357\" data-end=\"1749\"\u003e\n\u003cli data-start=\"1357\" data-end=\"1425\"\u003e\n\u003cp data-start=\"1359\" data-end=\"1425\"\u003eEngaging hex provides \u003cstrong data-start=\"1381\" data-end=\"1423\"\u003eanti-rotation and positional stability\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1426\" data-end=\"1495\"\u003e\n\u003cp data-start=\"1428\" data-end=\"1495\"\u003eDesigned specifically for \u003cstrong data-start=\"1454\" data-end=\"1493\"\u003eM+ conical narrow platform implants\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1496\" data-end=\"1553\"\u003e\n\u003cp data-start=\"1498\" data-end=\"1553\"\u003eSuitable for \u003cstrong data-start=\"1511\" data-end=\"1551\"\u003esingle-unit provisional restorations\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1554\" data-end=\"1623\"\u003e\n\u003cp data-start=\"1556\" data-end=\"1623\"\u003ePlastic material allows easy chairside or laboratory modification\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1624\" data-end=\"1685\"\u003e\n\u003cp data-start=\"1626\" data-end=\"1685\"\u003eSecure fit through \u003cstrong data-start=\"1645\" data-end=\"1683\"\u003e11° Morse taper conical connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1686\" data-end=\"1749\"\u003e\n\u003cp data-start=\"1688\" data-end=\"1749\"\u003eSupplied with compatible prosthetic screw for immediate use\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1751\" data-end=\"1754\"\u003e\n\u003ch3 data-start=\"1756\" data-end=\"1792\"\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp data-start=\"1794\" data-end=\"1954\"\u003e\u003cstrong data-start=\"1794\" data-end=\"1859\"\u003eQ: Is this abutment compatible with internal-hex NP implants?\u003c\/strong\u003e\u003cbr data-start=\"1859\" data-end=\"1862\"\u003eNo. This abutment is compatible \u003cstrong data-start=\"1894\" data-end=\"1953\"\u003eonly with Alfa Gate M+ conical narrow platform implants\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"1956\" data-end=\"2083\"\u003e\u003cstrong data-start=\"1956\" data-end=\"2005\"\u003eQ: What does “with hex” mean in this product?\u003c\/strong\u003e\u003cbr data-start=\"2005\" data-end=\"2008\"\u003eIt means the abutment is \u003cstrong data-start=\"2033\" data-end=\"2045\"\u003eengaging\u003c\/strong\u003e, providing anti-rotational stability.\u003c\/p\u003e\n\u003cp data-start=\"2085\" data-end=\"2193\"\u003e\u003cstrong data-start=\"2085\" data-end=\"2121\"\u003eQ: Is this a permanent abutment?\u003c\/strong\u003e\u003cbr data-start=\"2121\" data-end=\"2124\"\u003eNo. It is intended for \u003cstrong data-start=\"2147\" data-end=\"2192\"\u003etemporary \/ provisional restorations only\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"2195\" data-end=\"2294\"\u003e\u003cstrong data-start=\"2195\" data-end=\"2243\"\u003eQ: What tightening torque should be applied?\u003c\/strong\u003e\u003cbr data-start=\"2243\" data-end=\"2246\"\u003eThe recommended tightening torque is \u003cstrong data-start=\"2283\" data-end=\"2293\"\u003e25 Ncm\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"2296\" data-end=\"2406\"\u003e\u003cstrong data-start=\"2296\" data-end=\"2336\"\u003eQ: Is the prosthetic screw included?\u003c\/strong\u003e\u003cbr data-start=\"2336\" data-end=\"2339\"\u003eYes. The abutment is supplied with \u003cstrong data-start=\"2374\" data-end=\"2405\"\u003eprosthetic screw AGM-202-RP\u003c\/strong\u003e.\u003c\/p\u003e","brand":"Alfa Gate","offers":[{"title":"NARROW CONICAL PLATFORM \/ SCREW RETAINED ABUTMENTS","offer_id":44998001819900,"sku":"AGM-P3-NP","price":15.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0657\/2788\/9660\/files\/Plasticabutmentsfor-castingHEx_846f2379-622e-48f8-b747-16977799bc6c.png?v=1706016373","url":"https:\/\/alfa-gate.ps\/products\/plastic-abutment-with-hex-np","provider":"alfa-gate","version":"1.0","type":"link"}