{"product_id":"s-line-ball-attachment-o3-7-mm","title":"S-Line Ball attachment Ø3.7 mm","description":"\u003cp data-start=\"63\" data-end=\"556\"\u003eThe \u003cstrong data-start=\"67\" data-end=\"111\"\u003eAlfa Gate S-Line Ball Attachment Ø3.7 mm\u003c\/strong\u003e is a precision overdenture retention component designed for use with \u003cstrong data-start=\"181\" data-end=\"207\"\u003e3.0 mm S-Line implants\u003c\/strong\u003e. Manufactured from high-strength \u003cstrong data-start=\"241\" data-end=\"283\"\u003eGrade 5 titanium alloy (Ti-6Al-4V ELI)\u003c\/strong\u003e, it provides reliable retention, long-term mechanical stability, and smooth prosthetic function for removable restorations. Its optimized spherical geometry ensures consistent engagement with attachment housings while maintaining patient comfort and prosthetic durability.\u003c\/p\u003e\n\u003chr data-start=\"558\" data-end=\"561\"\u003e\n\u003ch2 data-start=\"563\" data-end=\"594\"\u003e\u003cstrong data-start=\"566\" data-end=\"594\"\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-start=\"595\" data-end=\"1047\"\u003e\n\u003cli data-start=\"595\" data-end=\"647\"\u003e\n\u003cp data-start=\"597\" data-end=\"647\"\u003e\u003cstrong data-start=\"597\" data-end=\"614\"\u003eProduct Name:\u003c\/strong\u003e S-Line Ball Attachment Ø3.7 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"673\" data-end=\"718\"\u003e\n\u003cp data-start=\"675\" data-end=\"718\"\u003e\u003cstrong data-start=\"675\" data-end=\"702\"\u003ePlatform Compatibility:\u003c\/strong\u003e S-Line 3.0 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"719\" data-end=\"776\"\u003e\n\u003cp data-start=\"721\" data-end=\"776\"\u003e\u003cstrong data-start=\"721\" data-end=\"741\"\u003eConnection Type:\u003c\/strong\u003e Internal Hex – 2.0 mm (Straight)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"777\" data-end=\"812\"\u003e\n\u003cp data-start=\"779\" data-end=\"812\"\u003e\u003cstrong data-start=\"779\" data-end=\"792\"\u003eDiameter:\u003c\/strong\u003e Ø3.7 mm ball head\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"813\" data-end=\"869\"\u003e\n\u003cp data-start=\"815\" data-end=\"869\"\u003e\u003cstrong data-start=\"815\" data-end=\"828\"\u003eMaterial:\u003c\/strong\u003e Titanium Grade 5 Alloy (Ti-6Al-4V ELI)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"870\" data-end=\"925\"\u003e\n\u003cp data-start=\"872\" data-end=\"925\"\u003e\u003cstrong data-start=\"872\" data-end=\"894\"\u003eAvailable Heights:\u003c\/strong\u003e 1 mm, 2 mm, 3 mm, 4 mm, 5 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"926\" data-end=\"960\"\u003e\n\u003cp data-start=\"928\" data-end=\"960\"\u003e\u003cstrong data-start=\"928\" data-end=\"951\"\u003eRecommended Torque:\u003c\/strong\u003e 20 Ncm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"961\" data-end=\"995\"\u003e\n\u003cp data-start=\"963\" data-end=\"995\"\u003e\u003cstrong data-start=\"963\" data-end=\"974\"\u003eDriver:\u003c\/strong\u003e 1.25 mm hex driver\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"996\" data-end=\"1047\"\u003e\n\u003cp data-start=\"998\" data-end=\"1047\"\u003e\u003cstrong data-start=\"998\" data-end=\"1007\"\u003eType:\u003c\/strong\u003e Ball attachment overdenture connector\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1049\" data-end=\"1052\"\u003e\n\u003ch2 data-start=\"1054\" data-end=\"1084\"\u003e\u003cstrong data-start=\"1057\" data-end=\"1084\"\u003eKey Features \u0026amp; Benefits\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-start=\"1085\" data-end=\"1563\"\u003e\n\u003cli data-start=\"1085\" data-end=\"1186\"\u003e\n\u003cp data-start=\"1087\" data-end=\"1186\"\u003e\u003cstrong data-start=\"1087\" data-end=\"1107\"\u003eStable Retention\u003c\/strong\u003e — Provides secure overdenture fixation with consistent snap-fit performance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1187\" data-end=\"1294\"\u003e\n\u003cp data-start=\"1189\" data-end=\"1294\"\u003e\u003cstrong data-start=\"1189\" data-end=\"1212\"\u003eHigh Strength Alloy\u003c\/strong\u003e — Grade 5 titanium delivers excellent fatigue resistance and long service life.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1295\" data-end=\"1391\"\u003e\n\u003cp data-start=\"1297\" data-end=\"1391\"\u003e\u003cstrong data-start=\"1297\" data-end=\"1319\"\u003ePlatform Precision\u003c\/strong\u003e — Engineered specifically for S-Line internal hex interface accuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1392\" data-end=\"1477\"\u003e\n\u003cp data-start=\"1394\" data-end=\"1477\"\u003e\u003cstrong data-start=\"1394\" data-end=\"1414\"\u003eMultiple Heights\u003c\/strong\u003e — Enables soft-tissue compensation and prosthetic alignment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1478\" data-end=\"1563\"\u003e\n\u003cp data-start=\"1480\" data-end=\"1563\"\u003e\u003cstrong data-start=\"1480\" data-end=\"1499\"\u003eWear Resistance\u003c\/strong\u003e — Smooth spherical head reduces friction and attachment wear.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1565\" data-end=\"1568\"\u003e\n\u003ch2 data-start=\"1570\" data-end=\"1597\"\u003e\u003cstrong data-start=\"1573\" data-end=\"1597\"\u003eClinical Indications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-start=\"1598\" data-end=\"1753\"\u003e\n\u003cli data-start=\"1598\" data-end=\"1631\"\u003e\n\u003cp data-start=\"1600\" data-end=\"1631\"\u003eImplant-retained overdentures\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1632\" data-end=\"1670\"\u003e\n\u003cp data-start=\"1634\" data-end=\"1670\"\u003eRemovable prosthetic stabilization\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1671\" data-end=\"1708\"\u003e\n\u003cp data-start=\"1673\" data-end=\"1708\"\u003eNarrow-ridge S-Line implant cases\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1709\" data-end=\"1753\"\u003e\n\u003cp data-start=\"1711\" data-end=\"1753\"\u003eSituations requiring resilient retention\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1755\" data-end=\"1758\"\u003e\n\u003ch2 data-start=\"1760\" data-end=\"1770\"\u003e\u003cstrong data-start=\"1763\" data-end=\"1770\"\u003eFAQ\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"1772\" data-end=\"1884\"\u003e\u003cstrong data-start=\"1772\" data-end=\"1819\"\u003eIs this compatible with NP or RP platforms?\u003c\/strong\u003e\u003cbr data-start=\"1819\" data-end=\"1822\"\u003eNo. It is designed exclusively for \u003cstrong data-start=\"1857\" data-end=\"1883\"\u003eS-Line 3.0 mm implants\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"1886\" data-end=\"1976\"\u003e\u003cstrong data-start=\"1886\" data-end=\"1920\"\u003eWhat torque should be applied?\u003c\/strong\u003e\u003cbr data-start=\"1920\" data-end=\"1923\"\u003eTighten to \u003cstrong data-start=\"1934\" data-end=\"1944\"\u003e20 Ncm\u003c\/strong\u003e using a \u003cstrong data-start=\"1953\" data-end=\"1975\"\u003e1.25 mm hex driver\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"1978\" data-end=\"2171\"\u003e\u003cstrong data-start=\"1978\" data-end=\"2044\"\u003eWhy choose a ball attachment instead of a locator-type system?\u003c\/strong\u003e\u003cbr data-start=\"2044\" data-end=\"2047\"\u003eBall attachments provide resilient retention, simplified maintenance, and reliable long-term function for overdenture cases.\u003c\/p\u003e\n\u003cp data-start=\"2173\" data-end=\"2294\"\u003e\u003cstrong data-start=\"2173\" data-end=\"2208\"\u003eAre replacement caps available?\u003c\/strong\u003e\u003cbr data-start=\"2208\" data-end=\"2211\"\u003eYes. Standard plastic caps are compatible for maintenance and retention adjustment.\u003c\/p\u003e","brand":"Alfa Gate","offers":[{"title":"1 mm \/ S-LINE PLATFORM \/ BALL ATTACHMENT","offer_id":43719104528636,"sku":"AGM-105-1S","price":23.0,"currency_code":"USD","in_stock":true},{"title":"2 mm \/ S-LINE PLATFORM \/ BALL ATTACHMENT","offer_id":43719104561404,"sku":"AGM-105-2S","price":23.0,"currency_code":"USD","in_stock":true},{"title":"3 mm \/ S-LINE PLATFORM \/ BALL ATTACHMENT","offer_id":43719104594172,"sku":"AGM-105-3S","price":23.0,"currency_code":"USD","in_stock":true},{"title":"4 mm \/ S-LINE PLATFORM \/ BALL ATTACHMENT","offer_id":43719104626940,"sku":"AGM-105-4S","price":23.0,"currency_code":"USD","in_stock":true},{"title":"5 mm \/ S-LINE PLATFORM \/ BALL ATTACHMENT","offer_id":43719104659708,"sku":"AGM-105-5S","price":23.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0657\/2788\/9660\/products\/AGM-105-2S.png?v=1662882360","url":"https:\/\/alfa-gate.ps\/products\/s-line-ball-attachment-o3-7-mm","provider":"alfa-gate","version":"1.0","type":"link"}