{"product_id":"s-line-transfer-for-open-tray-impression","title":"S-Line Transfer (for open tray impression)","description":"\u003cp data-start=\"71\" data-end=\"468\"\u003eThe \u003cstrong data-start=\"75\" data-end=\"114\"\u003eAlfa Gate S-Line Open Tray Transfer\u003c\/strong\u003e is a precision impression coping designed for accurate implant position capture using the open tray (pick-up) technique. Engineered specifically for the \u003cstrong data-start=\"268\" data-end=\"336\"\u003e3.0 mm S-Line internal hex platform (2.0 mm straight connection)\u003c\/strong\u003e, it ensures stable fixation during impression procedures and precise transfer of implant angulation and depth to the working model.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003ciframe title=\"Implant impression taking- open tray | Alfa Gate\" src=\"https:\/\/www.youtube.com\/embed\/ZjrKAG0hzWU\" height=\"720\" width=\"1280\"\u003e\u003c\/iframe\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2 data-start=\"475\" data-end=\"506\"\u003e\u003cstrong data-start=\"478\" data-end=\"506\"\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-start=\"507\" data-end=\"877\"\u003e\n\u003cli data-start=\"507\" data-end=\"556\"\u003e\n\u003cp data-start=\"509\" data-end=\"556\"\u003e\u003cstrong data-start=\"509\" data-end=\"526\"\u003eProduct Name:\u003c\/strong\u003e S-Line Transfer – Open Tray\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"557\" data-end=\"581\"\u003e\n\u003cp data-start=\"559\" data-end=\"581\"\u003e\u003cstrong data-start=\"559\" data-end=\"569\"\u003eSize:\u003c\/strong\u003e 14mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"582\" data-end=\"627\"\u003e\n\u003cp data-start=\"584\" data-end=\"627\"\u003e\u003cstrong data-start=\"584\" data-end=\"611\"\u003ePlatform Compatibility:\u003c\/strong\u003e S-Line 3.0 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"628\" data-end=\"685\"\u003e\n\u003cp data-start=\"630\" data-end=\"685\"\u003e\u003cstrong data-start=\"630\" data-end=\"650\"\u003eConnection Type:\u003c\/strong\u003e Internal Hex – 2.0 mm (Straight)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"686\" data-end=\"733\"\u003e\n\u003cp data-start=\"688\" data-end=\"733\"\u003e\u003cstrong data-start=\"688\" data-end=\"701\"\u003eMaterial:\u003c\/strong\u003e Medical-grade Stainless Steel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"734\" data-end=\"783\"\u003e\n\u003cp data-start=\"736\" data-end=\"783\"\u003e\u003cstrong data-start=\"736\" data-end=\"750\"\u003eTechnique:\u003c\/strong\u003e Open tray (pick-up) impression\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"784\" data-end=\"841\"\u003e\n\u003cp data-start=\"786\" data-end=\"841\"\u003e\u003cstrong data-start=\"786\" data-end=\"809\"\u003eRecommended Torque:\u003c\/strong\u003e 5–10 Ncm (light finger tight)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"842\" data-end=\"877\"\u003e\n\u003cp data-start=\"844\" data-end=\"877\"\u003e\u003cstrong data-start=\"844\" data-end=\"855\"\u003eDriver:\u003c\/strong\u003e 1.25 mm hand driver\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"879\" data-end=\"882\"\u003e\n\u003ch2 data-start=\"884\" data-end=\"903\"\u003e\u003cstrong data-start=\"887\" data-end=\"903\"\u003eKey Features\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-start=\"904\" data-end=\"1359\"\u003e\n\u003cli data-start=\"904\" data-end=\"1018\"\u003e\n\u003cp data-start=\"906\" data-end=\"1018\"\u003e\u003cstrong data-start=\"906\" data-end=\"926\"\u003ePick-Up Accuracy\u003c\/strong\u003e — Designed for direct impression removal with coping embedded in the impression material.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1019\" data-end=\"1101\"\u003e\n\u003cp data-start=\"1021\" data-end=\"1101\"\u003e\u003cstrong data-start=\"1021\" data-end=\"1047\"\u003eSecure Screw Retention\u003c\/strong\u003e — Ensures stable seating during impression capture.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1102\" data-end=\"1193\"\u003e\n\u003cp data-start=\"1104\" data-end=\"1193\"\u003e\u003cstrong data-start=\"1104\" data-end=\"1121\"\u003eHigh Rigidity\u003c\/strong\u003e — Stainless steel body prevents distortion under impression pressure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1194\" data-end=\"1277\"\u003e\n\u003cp data-start=\"1196\" data-end=\"1277\"\u003e\u003cstrong data-start=\"1196\" data-end=\"1229\"\u003ePrecise Interface Replication\u003c\/strong\u003e — Maintains exact S-Line 2.0 mm hex geometry.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1278\" data-end=\"1359\"\u003e\n\u003cp data-start=\"1280\" data-end=\"1359\"\u003e\u003cstrong data-start=\"1280\" data-end=\"1310\"\u003eControlled Torque Protocol\u003c\/strong\u003e — Low torque minimizes risk of component damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1361\" data-end=\"1364\"\u003e\n\u003ch2 data-start=\"1366\" data-end=\"1392\"\u003e\u003cstrong data-start=\"1369\" data-end=\"1392\"\u003eClinical Advantages\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-start=\"1393\" data-end=\"1585\"\u003e\n\u003cli data-start=\"1393\" data-end=\"1441\"\u003e\n\u003cp data-start=\"1395\" data-end=\"1441\"\u003eImproved accuracy for multiple implant cases\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1442\" data-end=\"1503\"\u003e\n\u003cp data-start=\"1444\" data-end=\"1503\"\u003eIdeal for full-arch or parallelism-sensitive restorations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1504\" data-end=\"1540\"\u003e\n\u003cp data-start=\"1506\" data-end=\"1540\"\u003eReduces positional discrepancies\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1541\" data-end=\"1585\"\u003e\n\u003cp data-start=\"1543\" data-end=\"1585\"\u003eEnhances passive fit of final prosthesis\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1587\" data-end=\"1590\"\u003e\n\u003ch2 data-start=\"1592\" data-end=\"1610\"\u003e\u003cstrong data-start=\"1595\" data-end=\"1610\"\u003eIndications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-start=\"1611\" data-end=\"1738\"\u003e\n\u003cli data-start=\"1611\" data-end=\"1638\"\u003e\n\u003cp data-start=\"1613\" data-end=\"1638\"\u003eMulti-unit restorations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1639\" data-end=\"1658\"\u003e\n\u003cp data-start=\"1641\" data-end=\"1658\"\u003eFull-arch cases\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1659\" data-end=\"1685\"\u003e\n\u003cp data-start=\"1661\" data-end=\"1685\"\u003eDeep implant placement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1686\" data-end=\"1738\"\u003e\n\u003cp data-start=\"1688\" data-end=\"1738\"\u003eSituations requiring maximum positional accuracy\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1740\" data-end=\"1743\"\u003e\n\u003ch2 data-start=\"1745\" data-end=\"1755\"\u003e\u003cstrong data-start=\"1748\" data-end=\"1755\"\u003eFAQ\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"1757\" data-end=\"1899\"\u003e\u003cstrong data-start=\"1757\" data-end=\"1812\"\u003eWhen should I use open tray instead of closed tray?\u003c\/strong\u003e\u003cbr data-start=\"1812\" data-end=\"1815\"\u003eOpen tray is recommended for multiple implants or when higher precision is required.\u003c\/p\u003e\n\u003cp data-start=\"1901\" data-end=\"2011\"\u003e\u003cstrong data-start=\"1901\" data-end=\"1946\"\u003eIs this compatible with NP or RP systems?\u003c\/strong\u003e\u003cbr data-start=\"1946\" data-end=\"1949\"\u003eNo. It is designed exclusively for \u003cstrong data-start=\"1984\" data-end=\"2010\"\u003eS-Line 3.0 mm implants\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"2013\" data-end=\"2123\"\u003e\u003cstrong data-start=\"2013\" data-end=\"2047\"\u003eWhat torque should be applied?\u003c\/strong\u003e\u003cbr data-start=\"2047\" data-end=\"2050\"\u003eApply \u003cstrong data-start=\"2056\" data-end=\"2094\"\u003e5–10 Ncm only (light finger tight)\u003c\/strong\u003e using a 1.25 mm hand driver.\u003c\/p\u003e\n\u003cp data-start=\"2125\" data-end=\"2219\"\u003e\u003cstrong data-start=\"2125\" data-end=\"2144\"\u003eIs it reusable?\u003c\/strong\u003e\u003cbr data-start=\"2144\" data-end=\"2147\"\u003eYes, if properly cleaned and sterilized according to standard protocols.\u003c\/p\u003e","brand":"Alfa Gate","offers":[{"title":"14mm \/ S-LINE PLATFORM \/ TRANSFERS","offer_id":43719165804796,"sku":"AGM-301-SL","price":18.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0657\/2788\/9660\/products\/AGM-301-SL.png?v=1662883165","url":"https:\/\/alfa-gate.ps\/products\/s-line-transfer-for-open-tray-impression","provider":"alfa-gate","version":"1.0","type":"link"}