{"product_id":"s-line-transfer-with-click-connection","title":"S-Line Transfer (With Click Connection)","description":"\u003cp\u003eThe \u003cstrong data-end=\"125\" data-start=\"74\"\u003eAlfa Gate S-Line Transfer with Click Connection\u003c\/strong\u003e is a precision impression component engineered for accurate implant position transfer in S-Line 3.0 mm systems. Designed with a secure click-lock mechanism, it ensures stable seating during impression procedures, minimizing movement and improving impression accuracy for reliable prosthetic fabrication.\u003c\/p\u003e\n\u003cp\u003e\u003ciframe title=\"Implant impression taking- closed tray | Alfa Gate\" src=\"https:\/\/www.youtube.com\/embed\/61UIDl5kQmM\" height=\"720\" width=\"1280\"\u003e\u003c\/iframe\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2 data-end=\"467\" data-start=\"436\"\u003e\u003cstrong data-end=\"467\" data-start=\"439\"\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-end=\"829\" data-start=\"468\"\u003e\n\u003cli data-end=\"527\" data-start=\"468\"\u003e\n\u003cp data-end=\"527\" data-start=\"470\"\u003e\u003cstrong data-end=\"487\" data-start=\"470\"\u003eProduct Name:\u003c\/strong\u003e S-Line Transfer With Click Connection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"527\" data-start=\"468\"\u003e\n\u003cstrong\u003eSize:\u003c\/strong\u003e 9mm\u003c\/li\u003e\n\u003cli data-end=\"598\" data-start=\"553\"\u003e\n\u003cp data-end=\"598\" data-start=\"555\"\u003e\u003cstrong data-end=\"582\" data-start=\"555\"\u003ePlatform Compatibility:\u003c\/strong\u003e S-Line 3.0 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"665\" data-start=\"599\"\u003e\n\u003cp data-end=\"665\" data-start=\"601\"\u003e\u003cstrong data-end=\"621\" data-start=\"601\"\u003eConnection Type:\u003c\/strong\u003e Internal hex – 2.0 mm (straight geometry)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"713\" data-start=\"666\"\u003e\n\u003cp data-end=\"713\" data-start=\"668\"\u003e\u003cstrong data-end=\"681\" data-start=\"668\"\u003eMaterial:\u003c\/strong\u003e Medical-grade Stainless Steel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"772\" data-start=\"714\"\u003e\n\u003cp data-end=\"772\" data-start=\"716\"\u003e\u003cstrong data-end=\"724\" data-start=\"716\"\u003eUse:\u003c\/strong\u003e Impression taking \/ implant position transfer\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"829\" data-start=\"773\"\u003e\n\u003cp data-end=\"829\" data-start=\"775\"\u003e\u003cstrong data-end=\"799\" data-start=\"775\"\u003eRetention Mechanism:\u003c\/strong\u003e Mechanical click engagement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"834\" data-start=\"831\"\u003e\n\u003ch2 data-end=\"866\" data-start=\"836\"\u003e\u003cstrong data-end=\"866\" data-start=\"839\"\u003eKey Features \u0026amp; Benefits\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-end=\"1309\" data-start=\"867\"\u003e\n\u003cli data-end=\"962\" data-start=\"867\"\u003e\n\u003cp data-end=\"962\" data-start=\"869\"\u003e\u003cstrong data-end=\"893\" data-start=\"869\"\u003eClick-Lock Stability\u003c\/strong\u003e — Audible and tactile seating confirmation for secure positioning.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1056\" data-start=\"963\"\u003e\n\u003cp data-end=\"1056\" data-start=\"965\"\u003e\u003cstrong data-end=\"986\" data-start=\"965\"\u003eAccurate Transfer\u003c\/strong\u003e — Maintains exact implant orientation during impression procedures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1152\" data-start=\"1057\"\u003e\n\u003cp data-end=\"1152\" data-start=\"1059\"\u003e\u003cstrong data-end=\"1081\" data-start=\"1059\"\u003eRigid Construction\u003c\/strong\u003e — Stainless steel body resists distortion under impression pressure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1226\" data-start=\"1153\"\u003e\n\u003cp data-end=\"1226\" data-start=\"1155\"\u003e\u003cstrong data-end=\"1177\" data-start=\"1155\"\u003eEfficient Workflow\u003c\/strong\u003e — Simplifies impression placement and removal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1309\" data-start=\"1227\"\u003e\n\u003cp data-end=\"1309\" data-start=\"1229\"\u003e\u003cstrong data-end=\"1251\" data-start=\"1229\"\u003ePlatform Precision\u003c\/strong\u003e — Specifically calibrated for S-Line connection geometry.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"1314\" data-start=\"1311\"\u003e\n\u003ch2 data-end=\"1344\" data-start=\"1316\"\u003e\u003cstrong data-end=\"1344\" data-start=\"1319\"\u003eClinical Applications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-end=\"1490\" data-start=\"1345\"\u003e\n\u003cli data-end=\"1382\" data-start=\"1345\"\u003e\n\u003cp data-end=\"1382\" data-start=\"1347\"\u003eClosed tray impression procedures\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1411\" data-start=\"1383\"\u003e\n\u003cp data-end=\"1411\" data-start=\"1385\"\u003eSingle-unit restorations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1446\" data-start=\"1412\"\u003e\n\u003cp data-end=\"1446\" data-start=\"1414\"\u003eMulti-unit prosthetic planning\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1490\" data-start=\"1447\"\u003e\n\u003cp data-end=\"1490\" data-start=\"1449\"\u003eDigital or conventional workflow models\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"1495\" data-start=\"1492\"\u003e\n\u003ch2 data-end=\"1507\" data-start=\"1497\"\u003e\u003cstrong data-end=\"1507\" data-start=\"1500\"\u003eFAQ\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-end=\"1620\" data-start=\"1509\"\u003e\u003cstrong data-end=\"1555\" data-start=\"1509\"\u003eIs this compatible with NP or RP implants?\u003c\/strong\u003e\u003cbr data-end=\"1558\" data-start=\"1555\"\u003eNo. It is designed exclusively for \u003cstrong data-end=\"1619\" data-start=\"1593\"\u003eS-Line 3.0 mm implants\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-end=\"1769\" data-start=\"1622\"\u003e\u003cstrong data-end=\"1670\" data-start=\"1622\"\u003eWhat is the purpose of the click connection?\u003c\/strong\u003e\u003cbr data-end=\"1673\" data-start=\"1670\"\u003eThe click mechanism confirms full seating and prevents micro-movement during impression capture.\u003c\/p\u003e\n\u003cp data-end=\"1865\" data-start=\"1771\"\u003e\u003cstrong data-end=\"1790\" data-start=\"1771\"\u003eIs it reusable?\u003c\/strong\u003e\u003cbr data-end=\"1793\" data-start=\"1790\"\u003eYes, if sterilized and handled according to standard clinical protocols.\u003c\/p\u003e","brand":"Alfa Gate","offers":[{"title":"9mm \/ S-LINE PLATFORM \/ TRANSFERS","offer_id":43719197229308,"sku":"AGM-302-SL","price":30.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0657\/2788\/9660\/products\/AGM-302-SL.png?v=1662883607","url":"https:\/\/alfa-gate.ps\/products\/s-line-transfer-with-click-connection","provider":"alfa-gate","version":"1.0","type":"link"}