{"product_id":"standard-platform-direct-prosthetic-screw","title":"Standard Platform Direct Prosthetic Screw","description":"\u003cp\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003eThe \u003c\/span\u003e\u003cstrong data-start=\"421\" data-end=\"466\" style=\"font-size: 0.875rem;\"\u003eStandard Platform Direct Prosthetic Screw\u003c\/strong\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003e is designed for the secure fixation of prosthetic components directly to \u003c\/span\u003e\u003cstrong data-start=\"540\" data-end=\"575\" style=\"font-size: 0.875rem;\"\u003eSP (Standard Platform) implants\u003c\/strong\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003e featuring an \u003c\/span\u003e\u003cstrong data-start=\"589\" data-end=\"616\" style=\"font-size: 0.875rem;\"\u003einternal hex connection\u003c\/strong\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"417\" data-end=\"783\"\u003eManufactured from high-strength titanium, it ensures reliable retention, precise fit, and stable prosthetic performance in single-unit and multi-unit restorations.\u003c\/p\u003e\n\u003cp data-start=\"785\" data-end=\"868\"\u003eThis screw is intended for \u003cstrong data-start=\"812\" data-end=\"841\"\u003efinal prosthetic fixation\u003c\/strong\u003e within SP implant systems.\u003c\/p\u003e\n\u003chr data-start=\"870\" data-end=\"873\"\u003e\n\u003ch2 data-start=\"875\" data-end=\"906\"\u003e\u003cstrong data-start=\"878\" data-end=\"906\"\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-start=\"908\" data-end=\"1231\"\u003e\n\u003cli data-start=\"908\" data-end=\"953\"\u003e\n\u003cp data-start=\"910\" data-end=\"953\"\u003e\u003cstrong data-start=\"910\" data-end=\"927\"\u003eProduct Type:\u003c\/strong\u003e Direct Prosthetic Screw\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"954\" data-end=\"998\"\u003e\n\u003cp data-start=\"956\" data-end=\"998\"\u003e\u003cstrong data-start=\"956\" data-end=\"969\"\u003ePlatform:\u003c\/strong\u003e \u003cstrong data-start=\"970\" data-end=\"996\"\u003eSP – Standard Platform\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"999\" data-end=\"1046\"\u003e\n\u003cp data-start=\"1001\" data-end=\"1046\"\u003e\u003cstrong data-start=\"1001\" data-end=\"1021\"\u003eConnection Type:\u003c\/strong\u003e Internal hex (2.42 mm)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1047\" data-end=\"1089\"\u003e\n\u003cp data-start=\"1049\" data-end=\"1089\"\u003e\u003cstrong data-start=\"1049\" data-end=\"1069\"\u003eInterface Angle:\u003c\/strong\u003e 45° (non-conical)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1090\" data-end=\"1112\"\u003e\n\u003cp data-start=\"1092\" data-end=\"1112\"\u003e\u003cstrong data-start=\"1092\" data-end=\"1103\"\u003eHeight:\u003c\/strong\u003e 7.7 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1113\" data-end=\"1153\"\u003e\n\u003cp data-start=\"1115\" data-end=\"1153\"\u003e\u003cstrong data-start=\"1115\" data-end=\"1128\"\u003eMaterial:\u003c\/strong\u003e Medical-grade Titanium\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1154\" data-end=\"1192\"\u003e\n\u003cp data-start=\"1156\" data-end=\"1192\"\u003e\u003cstrong data-start=\"1156\" data-end=\"1179\"\u003eRecommended Torque:\u003c\/strong\u003e \u003cstrong data-start=\"1180\" data-end=\"1190\"\u003e25 Ncm\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1193\" data-end=\"1231\"\u003e\n\u003cp data-start=\"1195\" data-end=\"1231\"\u003e\u003cstrong data-start=\"1195\" data-end=\"1203\"\u003eUse:\u003c\/strong\u003e Final prosthetic fixation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1233\" data-end=\"1236\"\u003e\n\u003ch2 data-start=\"1238\" data-end=\"1268\"\u003e\u003cstrong data-start=\"1241\" data-end=\"1268\"\u003eKey Features \u0026amp; Benefits\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-start=\"1270\" data-end=\"1826\"\u003e\n\u003cli data-start=\"1270\" data-end=\"1384\"\u003e\n\u003cp data-start=\"1272\" data-end=\"1384\"\u003e\u003cstrong data-start=\"1272\" data-end=\"1326\"\u003eDesigned specifically for SP internal hex implants\u003c\/strong\u003e\u003cbr data-start=\"1326\" data-end=\"1329\"\u003eFully compatible with Standard Platform (SP) systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1386\" data-end=\"1480\"\u003e\n\u003cp data-start=\"1388\" data-end=\"1480\"\u003e\u003cstrong data-start=\"1388\" data-end=\"1425\"\u003eInternal hex engagement (2.42 mm)\u003c\/strong\u003e\u003cbr data-start=\"1425\" data-end=\"1428\"\u003eEnsures accurate seating and rotational stability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1482\" data-end=\"1612\"\u003e\n\u003cp data-start=\"1484\" data-end=\"1612\"\u003e\u003cstrong data-start=\"1484\" data-end=\"1536\"\u003eTitanium construction for mechanical reliability\u003c\/strong\u003e\u003cbr data-start=\"1536\" data-end=\"1539\"\u003eHigh strength, corrosion resistance, and long-term clinical durability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1614\" data-end=\"1728\"\u003e\n\u003cp data-start=\"1616\" data-end=\"1728\"\u003e\u003cstrong data-start=\"1616\" data-end=\"1646\"\u003eDirect prosthetic fixation\u003c\/strong\u003e\u003cbr data-start=\"1646\" data-end=\"1649\"\u003eIdeal for securing abutments and prosthetic components without intermediates.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1730\" data-end=\"1826\"\u003e\n\u003cp data-start=\"1732\" data-end=\"1826\"\u003e\u003cstrong data-start=\"1732\" data-end=\"1762\"\u003eControlled torque protocol\u003c\/strong\u003e\u003cbr data-start=\"1762\" data-end=\"1765\"\u003eSupports predictable preload and minimizes screw loosening.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1828\" data-end=\"1831\"\u003e\n\u003ch2 data-start=\"1833\" data-end=\"1872\"\u003e\u003cstrong data-start=\"1836\" data-end=\"1872\"\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"1874\" data-end=\"2024\"\u003e\u003cstrong data-start=\"1874\" data-end=\"1937\"\u003eQ1: Which implant connection is this screw compatible with?\u003c\/strong\u003e\u003cbr data-start=\"1937\" data-end=\"1940\"\u003eThis screw is compatible \u003cstrong data-start=\"1965\" data-end=\"2023\"\u003eonly with SP (Standard Platform) internal hex implants\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"2026\" data-end=\"2096\"\u003e\u003cstrong data-start=\"2026\" data-end=\"2088\"\u003eQ2: Is this screw compatible with NP, RP, or RC platforms?\u003c\/strong\u003e\u003cbr data-start=\"2088\" data-end=\"2091\"\u003eNo.\u003c\/p\u003e\n\u003cul data-start=\"2097\" data-end=\"2183\"\u003e\n\u003cli data-start=\"2097\" data-end=\"2130\"\u003e\n\u003cp data-start=\"2099\" data-end=\"2130\"\u003eNP \u0026amp; RP = conical connections\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2131\" data-end=\"2183\"\u003e\n\u003cp data-start=\"2133\" data-end=\"2183\"\u003eRC = TRIO Morse taper\u003cbr data-start=\"2154\" data-end=\"2157\"\u003eThis screw is \u003cstrong data-start=\"2171\" data-end=\"2182\"\u003eSP-only\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2185\" data-end=\"2307\"\u003e\u003cstrong data-start=\"2185\" data-end=\"2223\"\u003eQ3: What torque should be applied?\u003c\/strong\u003e\u003cbr data-start=\"2223\" data-end=\"2226\"\u003eThe recommended torque is \u003cstrong data-start=\"2252\" data-end=\"2262\"\u003e25 Ncm\u003c\/strong\u003e, following standard SP prosthetic protocols.\u003c\/p\u003e\n\u003cp data-start=\"2309\" data-end=\"2414\"\u003e\u003cstrong data-start=\"2309\" data-end=\"2358\"\u003eQ4: Is this screw intended for temporary use?\u003c\/strong\u003e\u003cbr data-start=\"2358\" data-end=\"2361\"\u003eNo. It is intended for \u003cstrong data-start=\"2384\" data-end=\"2413\"\u003efinal prosthetic fixation\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"2416\" data-end=\"2487\"\u003e\u003cstrong data-start=\"2416\" data-end=\"2461\"\u003eQ5: What material is the screw made from?\u003c\/strong\u003e\u003cbr data-start=\"2461\" data-end=\"2464\"\u003eMedical-grade titanium.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Alfa Gate","offers":[{"title":"SP PLATFORM \/ CEMENTED ABUTMENTS","offer_id":44997342888188,"sku":"AGM-202","price":5.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0657\/2788\/9660\/files\/DirectProstheticScrewAGM-202.png?v=1706007132","url":"https:\/\/alfa-gate.ps\/products\/standard-platform-direct-prosthetic-screw","provider":"alfa-gate","version":"1.0","type":"link"}