{"product_id":"straight-abutment","title":"Straight Abutments (NP-RP)","description":"\u003cp data-start=\"127\" data-end=\"622\"\u003eThe \u003cstrong data-start=\"131\" data-end=\"170\"\u003eAlfa Gate Straight Abutment (NP–RP)\u003c\/strong\u003e is a precision-machined prosthetic component designed for straight implant restorations where ideal implant positioning allows direct prosthetic alignment. Manufactured from medical-grade titanium, it ensures excellent mechanical strength, biocompatibility, and long-term stability. Compatible with both \u003cstrong data-start=\"475\" data-end=\"515\"\u003eNarrow and Regular Conical Platforms\u003c\/strong\u003e, this abutment supports accurate seating, optimal load distribution, and predictable restorative outcomes.\u003c\/p\u003e\n\u003chr data-start=\"624\" data-end=\"627\"\u003e\n\u003ch2 data-start=\"629\" data-end=\"660\"\u003e\u003cstrong data-start=\"632\" data-end=\"660\"\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-start=\"661\" data-end=\"1015\"\u003e\n\u003cli data-start=\"661\" data-end=\"708\"\u003e\n\u003cp data-start=\"663\" data-end=\"708\"\u003e\u003cstrong data-start=\"663\" data-end=\"680\"\u003eProduct Name:\u003c\/strong\u003e Straight Abutment (NP–RP)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"734\" data-end=\"868\"\u003e\n\u003cp data-start=\"736\" data-end=\"765\"\u003e\u003cstrong data-start=\"736\" data-end=\"763\"\u003ePlatform Compatibility:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"768\" data-end=\"868\"\u003e\n\u003cli data-start=\"768\" data-end=\"816\"\u003e\n\u003cp data-start=\"770\" data-end=\"816\"\u003eNarrow Conical Platform (NP) — 2.23 mm \/ 22°\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"819\" data-end=\"868\"\u003e\n\u003cp data-start=\"821\" data-end=\"868\"\u003eRegular Conical Platform (RP) — 2.65 mm \/ 22°\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"869\" data-end=\"907\"\u003e\n\u003cp data-start=\"871\" data-end=\"907\"\u003e\u003cstrong data-start=\"871\" data-end=\"893\"\u003eAvailable Heights:\u003c\/strong\u003e 9 mm, 13 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"908\" data-end=\"948\"\u003e\n\u003cp data-start=\"910\" data-end=\"948\"\u003e\u003cstrong data-start=\"910\" data-end=\"923\"\u003eMaterial:\u003c\/strong\u003e Medical-grade Titanium\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"949\" data-end=\"980\"\u003e\n\u003cp data-start=\"951\" data-end=\"980\"\u003e\u003cstrong data-start=\"951\" data-end=\"960\"\u003eType:\u003c\/strong\u003e Straight Abutment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"981\" data-end=\"1015\"\u003e\n\u003cp data-start=\"983\" data-end=\"1015\"\u003e\u003cstrong data-start=\"983\" data-end=\"1006\"\u003eRecommended Torque:\u003c\/strong\u003e 25 Ncm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1017\" data-end=\"1020\"\u003e\n\u003ch2 data-start=\"1022\" data-end=\"1052\"\u003e\u003cstrong data-start=\"1025\" data-end=\"1052\"\u003eKey Features \u0026amp; Benefits\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-start=\"1053\" data-end=\"1418\"\u003e\n\u003cli data-start=\"1053\" data-end=\"1124\"\u003e\n\u003cp data-start=\"1055\" data-end=\"1124\"\u003e\u003cstrong data-start=\"1055\" data-end=\"1078\"\u003ePrecision Machining\u003c\/strong\u003e — Ensures passive fit and accurate seating.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1125\" data-end=\"1200\"\u003e\n\u003cp data-start=\"1127\" data-end=\"1200\"\u003e\u003cstrong data-start=\"1127\" data-end=\"1153\"\u003eHigh Strength Titanium\u003c\/strong\u003e — Provides long-term mechanical reliability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1201\" data-end=\"1273\"\u003e\n\u003cp data-start=\"1203\" data-end=\"1273\"\u003e\u003cstrong data-start=\"1203\" data-end=\"1234\"\u003eDual Platform Compatibility\u003c\/strong\u003e — Works with both NP and RP systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1274\" data-end=\"1346\"\u003e\n\u003cp data-start=\"1276\" data-end=\"1346\"\u003e\u003cstrong data-start=\"1276\" data-end=\"1305\"\u003eOptimal Load Distribution\u003c\/strong\u003e — Supports stable prosthetic function.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1347\" data-end=\"1418\"\u003e\n\u003cp data-start=\"1349\" data-end=\"1418\"\u003e\u003cstrong data-start=\"1349\" data-end=\"1375\"\u003eProsthetic Versatility\u003c\/strong\u003e — Suitable for multiple restoration types.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1420\" data-end=\"1423\"\u003e\n\u003ch2 data-start=\"1425\" data-end=\"1452\"\u003e\u003cstrong data-start=\"1428\" data-end=\"1452\"\u003eClinical Indications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-start=\"1453\" data-end=\"1604\"\u003e\n\u003cli data-start=\"1453\" data-end=\"1486\"\u003e\n\u003cp data-start=\"1455\" data-end=\"1486\"\u003eStraight implant restorations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1487\" data-end=\"1516\"\u003e\n\u003cp data-start=\"1489\" data-end=\"1516\"\u003eSingle crowns and bridges\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1517\" data-end=\"1556\"\u003e\n\u003cp data-start=\"1519\" data-end=\"1556\"\u003eCases with ideal implant angulation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1557\" data-end=\"1604\"\u003e\n\u003cp data-start=\"1559\" data-end=\"1604\"\u003ePosterior and anterior prosthetic solutions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1606\" data-end=\"1609\"\u003e\n\u003ch2 data-start=\"1611\" data-end=\"1621\"\u003e\u003cstrong data-start=\"1614\" data-end=\"1621\"\u003eFAQ\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"1623\" data-end=\"1804\"\u003e\u003cstrong data-start=\"1623\" data-end=\"1670\"\u003eQ: When should a straight abutment be used?\u003c\/strong\u003e\u003cbr data-start=\"1670\" data-end=\"1673\"\u003eA: When the implant is placed in an optimal axial position that allows direct prosthetic restoration without angulation correction.\u003c\/p\u003e\n\u003cp data-start=\"1806\" data-end=\"1935\"\u003e\u003cstrong data-start=\"1806\" data-end=\"1859\"\u003eQ: Is this compatible with all Alfa Gate systems?\u003c\/strong\u003e\u003cbr data-start=\"1859\" data-end=\"1862\"\u003eA: It is compatible with Alfa Gate NP and RP conical connection implants.\u003c\/p\u003e\n\u003cp data-start=\"1937\" data-end=\"2035\"\u003e\u003cstrong data-start=\"1937\" data-end=\"1974\"\u003eQ: What torque should be applied?\u003c\/strong\u003e\u003cbr data-start=\"1974\" data-end=\"1977\"\u003eA: Tighten to \u003cstrong data-start=\"1991\" data-end=\"2001\"\u003e25 Ncm\u003c\/strong\u003e using a calibrated torque driver.\u003c\/p\u003e\n\u003cp data-start=\"2037\" data-end=\"2160\"\u003e\u003cstrong data-start=\"2037\" data-end=\"2073\"\u003eQ: Which height should I choose?\u003c\/strong\u003e\u003cbr data-start=\"2073\" data-end=\"2076\"\u003eA: Select height based on gingival thickness and restorative clearance requirements.\u003c\/p\u003e","brand":"Alfa Gate","offers":[{"title":"NARROW CONICAL PLATFORM \/ 9mm \/ STRAIGHT ABUTMENTS","offer_id":43722083991804,"sku":"SSAC-9-NP","price":18.0,"currency_code":"USD","in_stock":true},{"title":"NARROW CONICAL PLATFORM \/ 13mm \/ STRAIGHT ABUTMENTS","offer_id":43722084024572,"sku":"SSAC-13-NP","price":18.0,"currency_code":"USD","in_stock":true},{"title":"REGULAR CONICAL PLATFORM \/ 9mm \/ STRAIGHT ABUTMENTS","offer_id":43722084057340,"sku":"SSAC-9-RP","price":18.0,"currency_code":"USD","in_stock":true},{"title":"REGULAR CONICAL PLATFORM \/ 13mm \/ STRAIGHT ABUTMENTS","offer_id":43722084090108,"sku":"SSAC-13-RP","price":18.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0657\/2788\/9660\/products\/SSAC-9-NP_1.png?v=1662967813","url":"https:\/\/alfa-gate.ps\/products\/straight-abutment","provider":"alfa-gate","version":"1.0","type":"link"}